075041061

Centraline Compact Line Rotary Actuator


Linkage of M6063L as replacement for M676A,C



0903403

Centraline Three-way control valve PN16, threaded connections DN15-50, V5078B


Adapter ring



43161276-001

Centraline Pneumatic actuator, MP953
High Temperature Applications, the following bonnet extentions must be used with MP953 actuators when the flowing medium temperature is 150 to 220 degrees C, to give extra air circulation and less conduction of heat from the valve body to the actuator.

Used with V5049A up to 65mm, V5050A up to 80mm, V5328A 40mm to 80mm, V5329A 40mm to 80mm



43191679-001

Centraline Actuator 3-pt, 20/38 mm 1800 N, ML6421
Accessories

Single feedback potentiometer 220/135 ohm operating range, for 20 mm models



43191679-002

Centraline Actuator 3-pt, 20/38 mm 1800 N, ML6421
Accessories

Single feedback potentiometer 220/135 ohm operating range, for 38 mm models



43191679-007

Centraline Actuator 3-pt, 20/38 mm 1800 N, ML6421
Accessories

Single feedback potentiometer 10 kohm operating range, for 20 mm models



43191679-008

Centraline Actuator 3-pt, 20/38 mm 1800 N, ML6421
Accessories

Single feedback potentiometer 10 kohm operating range, for 38 mm models



43191679-011

Centraline Actuator 3-pt, 20 mm 600 N, ML6420/ML6425
Accessories

Feedback potentiometer 10 kohm, operating range



43191679-012

Centraline Actuator 3-pt, 20 mm 600 N, ML6420/ML6425
Accessories

Feedback potentiometer 220 ohm operating range



43191680-002

Centraline Actuator 3-pt, 20/38 mm 1800 N, ML6421
Accessories

Dual end switches SPDT, adjustable (250 V~, 10 A)



43191680-005

Centraline Actuator 3-pt, 20 mm 600 N, ML6420/ML6425
Accessories

Dual end switches SPDT, adjustable (250 V~, 10 A)



43191680-205

Centraline Actuator 0/2..10V, 20 mm 600 N, ML7420/ML7425
Accessories

Auxiliary switch (250 V~, 10 A)



43196000-001

Centraline Actuator 3-pt, 20 mm 600 N, ML6420/ML6425
High temperature kits for:

V5011R/S, V5013R/E; V5328A/V5329A DN15..32



43196000-002

Centraline Actuator 3-pt, 20 mm 600 N, ML6420/ML6425
High temperature kits for:

V5016A/V5025A/V5050A DN15..80; V5049A DN15..65; V5095A DN20..80; V5328A/V5329A DN40..80



43196000-038

Centraline Actuator 3-pt, 20/38 mm 1800 N, ML6421
High temperature kits for:

V5015A/V5016A/V5025A/V5049A/V5050A/B/V5328A 38 mm



43297431-001

Centraline Pneumatic actuator, MP953
High Temperature Applications, the following bonnet extentions must be used with MP953 actuators when the flowing medium temperature is 150 to 220 degrees C, to give extra air circulation and less conduction of heat from the valve body to the actuator.

Used with V5011R,S, V5013R,E, V5328A 15mm to 32mm, V5329A 15mm to 32mm



5112-19/U

Centraline Two way characterized control ball valves, PN25, DN15-50, VBG2
Accessories for DN15..32 valves

Replacement stem assembly for VBG valve, DN15, DN20



5112-20/U

Centraline Two way characterized control ball valves, PN25, DN15-50, VBG2
Accessories for DN15..32 valves

Replacement stem assembly for VBG valve, DN25, DN32



5112-21/U

Centraline Two way characterized control ball valves, PN25, DN15-50, VBG2
Accessories for DN40, DN50 valves

Replacement stem assembly for VBG valve, DN40, DN50



5112-51/U

Centraline Two way characterized control ball valves, PN25, DN15-50, VBG2
Accessories for DN40, DN50 valves

Linkage set for VBG valves DN40, DN50 to M6061, M7061



5585100

Centraline Two-way control valve PN16, conical sealing DN15/20, V5822A
Accessories

Spare adjustment cap (pack of 10)



AC-15FS

Centraline Valve Small, Flat sealing, 2-way, PN16, DN15/20/25, VSxF-2
Accessories

Soldering fitting for DN15 valve, pipe size 12 mm



AC-15FT

Centraline Valve Small, Flat sealing, 2-way, PN16, DN15/20/25, VSxF-2
Accessories

External threaded fitting for DN15 valve, pipe size R3/8"



AC-15TF

Centraline Three-way control valve PN16, flat sealing DN15-50, V5013E
Accessories

Internal threaded fitting for DN15 valve, pipe size Rp1/2"



AC-15TF-1

Centraline Two way characterized control ball valves, PN25, DN15-50, VBG2
Accessories for DN15..32 valves

Internal threaded fitting for VBG DN15 valve, pipe size Rp 1/2"



AC-20FS

Centraline Valve Small, Flat sealing, 2-way, PN16, DN15/20/25, VSxF-2
Accessories

Soldering fitting for DN20 valve, pipe size 15 mm



AC-20FT

Centraline Valve Small, Flat sealing, 2-way, PN16, DN15/20/25, VSxF-2
Accessories

External threaded fitting for DN20 valve, pipe size R1/2"



AC-20TF

Centraline Three-way control valve PN16, flat sealing DN15-50, V5013E
Accessories

Internal threaded fitting for DN20 valve, pipe size Rp3/4"



AC-25T

Centraline Two-way control valve PN16, flat sealing DN25-40, V5832B
Accessories

External threaded fitting for DN25 valve, pipe size R1"



AC-25TF

Centraline Two-way control valve PN16, flat sealing DN25-40, V5832B
Accessories

Internal threaded fitting for DN25 valve, pipe size Rp1"



AC-32T

Centraline Two-way control valve PN16, flat sealing DN25-40, V5832B
Accessories

External threaded fitting for DN32 valve, pipe size R11/4"



AC-32TF

Centraline Two-way control valve PN16, flat sealing DN25-40, V5832B
Accessories

Internal threaded fitting for DN32 valve, pipe size Rp11/4"



AC-40T

Centraline Two-way control valve PN16, flat sealing DN25-40, V5832B
Accessories

External threaded fitting for DN40 valve, pipe size R11/2"



AC-40TF

Centraline Two-way control valve PN16, flat sealing DN25-40, V5832B
Accessories

Internal threaded fitting for DN40 valve, pipe size Rp11/2"



AC-50TF

Centraline Three-way control valve PN16, flat sealing DN15-50, V5013E
Accessories

Internal threaded fitting for DN50 valve, pipe size Rp2"



ACH28

Centraline RF Electronic radiator controller HR92
Valve adapters

Comap/Herz M28x1,5



ACN-15C

Centraline Valve Small, Conical sealing, 2-way, PN16, DN15/20/25, VSxC-2
Accessories

Compression fitting for DN15 valve, pipe size 15 mm



ACN-15S

Centraline Valve Small, Conical sealing, 2-way, PN16, DN15/20/25, VSxC-2
Accessories

Soldering fitting for DN15 valve, pipe size 12 mm



ACN-15T

Centraline Valve Small, Conical sealing, 2-way, PN16, DN15/20/25, VSxC-2
Accessories

External threaded fitting for DN15 valve, pipe size R3/8"



ACN-20C

Centraline Valve Small, Conical sealing, 2-way, PN16, DN15/20/25, VSxC-2
Accessories

Compression fitting for DN20 valve, pipe size 22 mm



ACN-20S

Centraline Valve Small, Conical sealing, 2-way, PN16, DN15/20/25, VSxC-2
Accessories

Soldering fitting for DN20 valve, pipe size 15 mm



ACN-20T

Centraline Valve Small, Conical sealing, 2-way, PN16, DN15/20/25, VSxC-2
Accessories

External threaded fitting for DN20 valve, pipe size R1/2"



ACN-25T

Centraline Valve Small, Conical sealing, 2-way, PN16, DN15/20/25, VSxC-2
Accessories

External threaded fitting for DN25 valve, pipe size R1"



ACS-25T

Centraline Valve Small, Flat sealing, 2-way, PN16, DN15/20/25, VSxF-2
Accessories

External threaded fitting for DN25 valve, pipe size R1"



ACS90

Centraline RF Electronic radiator controller HR92
Accessories

Cable for window contact HCA30



AF00-B54

Centraline Outdoor temperature sensor, Pt1000

Approvals: IEC751 class B
Temperature element: Pt1000
Temperature range: -40...70C
Mounting place: wall outside
Housing (HxWxD): 56mm|81mm|49mm
Wiring terminals: 2


Protection class: IP54


AF00-B65

Centraline Outdoor temperature sensor, Pt1000

Approvals: IEC751 class B
Temperature element: Pt1000
Temperature range: -40...70C
Mounting place: wall outside
Housing (HxWxD): 56mm|81mm|49mm
Wiring terminals: 2


Protection class: IP65


AF10-B54

Centraline Outdoor temperature sensor, NTC

Temperature range: -40...70C
Mounting place: wall outside
Housing (HxWxD): 56mm|81mm|49mm
Wiring terminals: 2


Temperature element: NTC10k
Protection class: IP54


AF20-B54

Centraline Outdoor temperature sensor, NTC

Temperature range: -40...70C
Mounting place: wall outside
Housing (HxWxD): 56mm|81mm|49mm
Wiring terminals: 2


Temperature element: NTC20k
Protection class: IP54


AF20-B65

Centraline Outdoor temperature sensor, NTC

Temperature range: -40...70C
Mounting place: wall outside
Housing (HxWxD): 56mm|81mm|49mm
Wiring terminals: 2


Temperature element: NTC20k
Protection class: IP65


AFA90

Centraline RF Electronic radiator controller HR92
Accessories

Dial with chromed cap (3 pieces in one pack)



AKA3

Centraline Heating, District Heating and Multi-Fuel OTC Controller, SMILE
Accessories for models with boiler burner output

Cable accessory



AOV30

Centraline RF Electronic radiator controller HR92
Valve adapters

M30x1,0



APS90

Centraline RF Electronic radiator controller HR92
Accessories

Power module for external power supply connection



AQS71-KAM-T

Centraline Air duct CO2 and temperature transmitter

For sensing or controlling of CO2 concentration, and temperature measurement in buildings.
Protection class: IP65 when probe mounted downwards, otherwise IP20
Output signal: The following output signals are applicable:
0..10 V for 0..2000 ppm CO2
0..10 V for 0..50 oC
Power supply: 24Vacdc
Mounting place: air duct
Wiring terminals: 5


AS2

Centraline Actuator for V5421B1090
Optional accessories

End switch



ATC928G2000

Centraline evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

Central controller (spare/system builder). Controller only.
Language option: EN/NL


ATC928G2019

Centraline evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

Central controller (spare/system builder). Controller only.
Language option: NL/FR


ATC928G2027

Centraline evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

Central controller (spare/system builder). Controller only.
Language option: DE/ES/IT


ATF100

Centraline evohome, colour screen multi-zone controller with remote access
Accessories for evohome

Table stand with power supply and EU power cord



ATF200

Centraline evohome, colour screen multi-zone controller with remote access
Accessories for evohome

Table stand with power supply and UK power cord



ATF300

Centraline evohome, colour screen multi-zone controller with remote access
Accessories for evohome

Wall pack with power supply



ATF400

Centraline evohome, colour screen multi-zone controller with remote access
Accessories for evohome

3 interchangable front covers (polished black, brushed metal, high-gloss white)



ATF500DHW

Centraline evohome, colour screen multi-zone controller with remote access
Stored hot water kit

Additional parts to add stored hot water to the system. It contains a Strap on sensor, Insertion sensor, RF- transmitter and BDR91 relay for valve control. This pack does not contain an evo controller.



ATP921G2034

Centraline evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

Base pack (single zone chronotherm). Controller with BDR91 boiler relay, table stand with plug.
Wiring connection: EU plug
Language option: NL/FR


ATP921G2042

Centraline evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

Base pack (single zone chronotherm). Controller with BDR91 boiler relay, table stand with plug.
Wiring connection: EU plug
Language option: DE/ES/IT


ATP921G2080

Centraline evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

Base pack (single zone chronotherm). Controller with BDR91 boiler relay, table stand with plug.
Wiring connection: UK plug
Language option: EN


ATP921R2100

Centraline evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

Connected pack (single zone with remote gateway). Controller with BDR91 boiler relay, remote gateway, table stand with plug.
Wiring connection: EU plug
Language option: NL/FR


ATP921R2118

Centraline evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

Connected pack (single zone with remote gateway). Controller with BDR91 boiler relay, remote gateway, table stand with plug.
Wiring connection: EU plug
Language option: DE/ES/IT


ATP924G2002

Centraline evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

4 Zone pack. Controller with 4x HR92, table stand with plug.
Wiring connection: EU plug
Language option: DE


ATP924G2010

Centraline evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

4 Zone Base pack. Controller with BDR91 relay, 4x HR92WE, table stand with plug.
Wiring connection: EU plug
Language option: NL/FR


ATP928G2074

Centraline evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

Underfloor pack (multi-zone). Controller with HCE80, HRA80, table stand with plug.
Wiring connection: EU plug
Language option: NL/FR


ATP951M2118

Centraline evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

Connected OpenTherm pack (single zone OpenTherm with gateway). Controller with RF bridge, Remote gateway, table stand with plug.
Wiring connection: EU plug
Language option: NL/FR


ATP954M2020

Centraline evohome, colour screen multi-zone controller with remote access

The high quality colour touch screen control can operate twelve separately time and temperature controlled zones plus a stored hot water system. Each zone has its own full seven day programme with a range of overrides and One touch actions to make using the system fast and convenient.
The controller is part of the evohome room control system and therefore also equipped with the proven wireless RF (868 MHz) technology. This allows the majority of heating systems to be upgraded with a minimum of disruption and re-wiring.
Two important new products have been added to the system, the HR92 range of radiator controllers and a Remote gateway RFG100 that allow access to the system via Android and Apple smartphones. A control system for radiators, underfloor heating, zone and mixing valves or a mixture of heating types in home or office environment with optional control for boilers, heat pumps and stored hot water.
evohome controller for individual zoning control a single or up to 12 zones per controller
unrivalled comfort, control and energy saving
fully customisable to suit individual heating systems and lifestyles
remote connectivity allowing Smartphone control away from home
intuitive local language operating menu structure and user guided programming
large colour backlit touch screen display with easy to read zone and temperature information
modern design with exchangeable front covers in polished black, brushed metal and gloss white
improved and simplified binding operation to reduce installation time and cost
proven wireless communication (no disruption of interior decor, ideally suitable for existing homes)
adaptive heating control continually adapts to climate and system heat load thought the year
optimisation features calculates heat-up and cool-down time allowing programming of actual heating needs
evotouch is supplied with 2 rechargeable batteries AA 1,2V NiMH and a charging stand
http://getconnected.honeywell.com
ErP Class: VIII

4 Zone Base OpenTherm pack. Controller with RF bridge, 4x HR92WE, table stand with plug.
Wiring connection: EU plug
Language option: NL/FR


ATU2040A

Centraline Rotary Actuator
Mounting kit for non-Honeywell valves

Universal kit for almost all valves



AVS90

Centraline RF Electronic radiator controller HR92
Accessories

Vandalism protection



BACA-A

Centraline Configurable BACnet room controller MERLIN
Tools for Commissioning

Wireless Adapter



BDR91A1000

Centraline evohome, colour screen multi-zone controller with remote access
Boiler control

Relay module 5 A



C7110A1010

Centraline Air quality sensor

For detection of unpleasant odours, tobacco smoke, and vapours emitted by such materials as furniture, carpets, paint, glue, etc.
Protection class: III as per EN60730-1I IP30 as per EN60529
Output signal: 0..10Vdc
Adjustable output offset and LED display
Power supply: 24Vacdc
Mounting place: internal wall
Housing (HxWxD): 104mm|99mm|30mm


C7110C1001A

Centraline Room temperature/ CO2 sensor

For sensing or controlling of CO2 concentration in buildings.
LED functions: operation as CO2 indicator
Output signal: CO2: 0..10 V for 0..2000 ppm (factory setting) or 0..3000 ppm
temperature: 0..10 V
Automatic baseline calibration, and quick calibration options.
Power supply: 24Vac
Mounting place: internal wall
Housing (HxWxD): 104mm|99mm|30mm


C7110D1009A

Centraline Room temperature/ CO2 sensor

For sensing or controlling of CO2 concentration; and temperature measurement in buildings.
LED functions: operation as occupancy indicator
Output signal: CO2: 0..10 V for 0..2000 ppm (factory setting) or 0..3000 ppm
Temperature setpoint potentiometer delivered with 4 setpoint wheels; white and blue, relative and absolute scale.
Automatic baseline calibration, and quick calibration options.
Temperature element: NTC20k
Temperature range: 10...35C
Setpoint knob: -5...5C
Extra setp. knob: 12...30C
Occupancy switch: auto/bypass
Power supply: 24Vac
Mounting place: internal wall
Housing (HxWxD): 104mm|99mm|30mm


CL-ROOMUP

Centraline Configurable BACnet room controller MERLIN
Tools for Commissioning

Mobile Commissioning Tool



CLAXARENA

Centraline Web based Supervisor software, ARENA AX

The ARENAAX is a Web based Supervisor with excellent integration capabilities for small to big size systems. It is a high sophisticated Solution to supervise HVAC systems and non-HVAC systems (e.g. Lighting, Security, Fire) in a building. It is used in applications where multiple HAWK and FALCON controllers will be networked together. The ARENAAX is a BACnet certified Supervisor, which fulfill the requirements of an Operating- and Advanced Workstation profile. The most common open systems based on TCP/IP communication standards like OPC (client), Modbus TCP, EIB KNX IP, and SNMP can be directly integrated by ARENAAX.
The ARENAAX serves real time graphical information displays to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. In addition, ARENAAX provides a comprehensive, graphical engineering toolset for application development.
ARENAAX includes built-in mobile support for some of the more commonly used features like property sheets, scheduling, alarm management and charting.
Features:
Provides access to alarms, logs, graphics, schedules, and configuration data with a standard web browser
FALCON plant controllers can be integrated free of charge, no 3rd party BACnet driver has to be used
Optional direct Ethernet based driver support for BACnet IP, OPC (Client), Modbus TCP, EIB/KNX IP and SNMP; additional point blocks for each driver may be purchased in blocks of 500 for each protocol
Certified BACnet drivers are available (OWS, AWS)
Java-enabled user interface (UI) which supports highly customizable dynamic graphics as well as a non-Java UI for browsers
Supports an unlimited number of users over the Internet / Intranet with a standard web browser, depending on the host PC
Optional Enterprise-level data archival using SQL, Oracle or DB2 database, and HTTP/HTML/XML text formats
'Audit Trail' of database changes, database storage and backup, global time functions, calendar, central scheduling, control, and energy management routines.
Sophisticated alarm processing and routing, including e-mail and SMS
Password protection and security using standard Java authentication and encryption techniques with optional security supported via an external LDAP connection
HTML-based help system that includes comprehensive on-line system documentation
Supports multiple HAWK stations connected to a local Ethernet network, or the Internet
A 'Small Building System' version is available for up to ten HAWKs


Model: ARENA AX Supervisor Software


CLAXARENAAPC

Centraline Web based Supervisor software, ARENA AX

The ARENAAX is a Web based Supervisor with excellent integration capabilities for small to big size systems. It is a high sophisticated Solution to supervise HVAC systems and non-HVAC systems (e.g. Lighting, Security, Fire) in a building. It is used in applications where multiple HAWK and FALCON controllers will be networked together. The ARENAAX is a BACnet certified Supervisor, which fulfill the requirements of an Operating- and Advanced Workstation profile. The most common open systems based on TCP/IP communication standards like OPC (client), Modbus TCP, EIB KNX IP, and SNMP can be directly integrated by ARENAAX.
The ARENAAX serves real time graphical information displays to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. In addition, ARENAAX provides a comprehensive, graphical engineering toolset for application development.
ARENAAX includes built-in mobile support for some of the more commonly used features like property sheets, scheduling, alarm management and charting.
Features:
Provides access to alarms, logs, graphics, schedules, and configuration data with a standard web browser
FALCON plant controllers can be integrated free of charge, no 3rd party BACnet driver has to be used
Optional direct Ethernet based driver support for BACnet IP, OPC (Client), Modbus TCP, EIB/KNX IP and SNMP; additional point blocks for each driver may be purchased in blocks of 500 for each protocol
Certified BACnet drivers are available (OWS, AWS)
Java-enabled user interface (UI) which supports highly customizable dynamic graphics as well as a non-Java UI for browsers
Supports an unlimited number of users over the Internet / Intranet with a standard web browser, depending on the host PC
Optional Enterprise-level data archival using SQL, Oracle or DB2 database, and HTTP/HTML/XML text formats
'Audit Trail' of database changes, database storage and backup, global time functions, calendar, central scheduling, control, and energy management routines.
Sophisticated alarm processing and routing, including e-mail and SMS
Password protection and security using standard Java authentication and encryption techniques with optional security supported via an external LDAP connection
HTML-based help system that includes comprehensive on-line system documentation
Supports multiple HAWK stations connected to a local Ethernet network, or the Internet
A 'Small Building System' version is available for up to ten HAWKs


Model: Alarmportal


CLAXARENAAXI

Centraline Web based Supervisor software, ARENA AX
CL AX Video Drivers

Axis Cameras video driver 16 Cameras



CLAXARENAAXI4

Centraline Web based Supervisor software, ARENA AX
CL AX Video Drivers

Additional 4 Cameras Axis video driver



CLAXARENADED

Centraline Web based Supervisor software, ARENA AX
CL AX Video Drivers

Dedicated Micros NetVu DVR video driver 16 Cameras



CLAXARENADED4

Centraline Web based Supervisor software, ARENA AX
CL AX Video Drivers

Additional 4 Cameras Dedicated Micros NetVu DVR video driver



CLAXARENAMIL

Centraline Web based Supervisor software, ARENA AX
CL AX Video Drivers

Milestone NVM video driver 16 Cameras



CLAXARENAMIL4

Centraline Web based Supervisor software, ARENA AX
CL AX Video Drivers

Additional 4 Cameras Milestone NVM video driver



CLAXARENARUP

Centraline Web based Supervisor software, ARENA AX
CL ARENA AX Upgrades

Upgrade of ARENA AX and associated drivers, upgrade to latest revision



CLAXARENASBS01

Centraline Web based Supervisor software, ARENA AX

The ARENAAX is a Web based Supervisor with excellent integration capabilities for small to big size systems. It is a high sophisticated Solution to supervise HVAC systems and non-HVAC systems (e.g. Lighting, Security, Fire) in a building. It is used in applications where multiple HAWK and FALCON controllers will be networked together. The ARENAAX is a BACnet certified Supervisor, which fulfill the requirements of an Operating- and Advanced Workstation profile. The most common open systems based on TCP/IP communication standards like OPC (client), Modbus TCP, EIB KNX IP, and SNMP can be directly integrated by ARENAAX.
The ARENAAX serves real time graphical information displays to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. In addition, ARENAAX provides a comprehensive, graphical engineering toolset for application development.
ARENAAX includes built-in mobile support for some of the more commonly used features like property sheets, scheduling, alarm management and charting.
Features:
Provides access to alarms, logs, graphics, schedules, and configuration data with a standard web browser
FALCON plant controllers can be integrated free of charge, no 3rd party BACnet driver has to be used
Optional direct Ethernet based driver support for BACnet IP, OPC (Client), Modbus TCP, EIB/KNX IP and SNMP; additional point blocks for each driver may be purchased in blocks of 500 for each protocol
Certified BACnet drivers are available (OWS, AWS)
Java-enabled user interface (UI) which supports highly customizable dynamic graphics as well as a non-Java UI for browsers
Supports an unlimited number of users over the Internet / Intranet with a standard web browser, depending on the host PC
Optional Enterprise-level data archival using SQL, Oracle or DB2 database, and HTTP/HTML/XML text formats
'Audit Trail' of database changes, database storage and backup, global time functions, calendar, central scheduling, control, and energy management routines.
Sophisticated alarm processing and routing, including e-mail and SMS
Password protection and security using standard Java authentication and encryption techniques with optional security supported via an external LDAP connection
HTML-based help system that includes comprehensive on-line system documentation
Supports multiple HAWK stations connected to a local Ethernet network, or the Internet
A 'Small Building System' version is available for up to ten HAWKs


Model: ARENA AX Supervisor Software for single HAWK, only available in bulks (more then 20)


CLAXARENASBS05B

Centraline Web based Supervisor software, ARENA AX

The ARENAAX is a Web based Supervisor with excellent integration capabilities for small to big size systems. It is a high sophisticated Solution to supervise HVAC systems and non-HVAC systems (e.g. Lighting, Security, Fire) in a building. It is used in applications where multiple HAWK and FALCON controllers will be networked together. The ARENAAX is a BACnet certified Supervisor, which fulfill the requirements of an Operating- and Advanced Workstation profile. The most common open systems based on TCP/IP communication standards like OPC (client), Modbus TCP, EIB KNX IP, and SNMP can be directly integrated by ARENAAX.
The ARENAAX serves real time graphical information displays to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. In addition, ARENAAX provides a comprehensive, graphical engineering toolset for application development.
ARENAAX includes built-in mobile support for some of the more commonly used features like property sheets, scheduling, alarm management and charting.
Features:
Provides access to alarms, logs, graphics, schedules, and configuration data with a standard web browser
FALCON plant controllers can be integrated free of charge, no 3rd party BACnet driver has to be used
Optional direct Ethernet based driver support for BACnet IP, OPC (Client), Modbus TCP, EIB/KNX IP and SNMP; additional point blocks for each driver may be purchased in blocks of 500 for each protocol
Certified BACnet drivers are available (OWS, AWS)
Java-enabled user interface (UI) which supports highly customizable dynamic graphics as well as a non-Java UI for browsers
Supports an unlimited number of users over the Internet / Intranet with a standard web browser, depending on the host PC
Optional Enterprise-level data archival using SQL, Oracle or DB2 database, and HTTP/HTML/XML text formats
'Audit Trail' of database changes, database storage and backup, global time functions, calendar, central scheduling, control, and energy management routines.
Sophisticated alarm processing and routing, including e-mail and SMS
Password protection and security using standard Java authentication and encryption techniques with optional security supported via an external LDAP connection
HTML-based help system that includes comprehensive on-line system documentation
Supports multiple HAWK stations connected to a local Ethernet network, or the Internet
A 'Small Building System' version is available for up to ten HAWKs


Model: ARENA AX Supervisor Software Small Building System, for up to 5 HAWK and 5 BACnet Controllers; Includes OWS feature


CLAXARENASBS10

Centraline Web based Supervisor software, ARENA AX

The ARENAAX is a Web based Supervisor with excellent integration capabilities for small to big size systems. It is a high sophisticated Solution to supervise HVAC systems and non-HVAC systems (e.g. Lighting, Security, Fire) in a building. It is used in applications where multiple HAWK and FALCON controllers will be networked together. The ARENAAX is a BACnet certified Supervisor, which fulfill the requirements of an Operating- and Advanced Workstation profile. The most common open systems based on TCP/IP communication standards like OPC (client), Modbus TCP, EIB KNX IP, and SNMP can be directly integrated by ARENAAX.
The ARENAAX serves real time graphical information displays to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. In addition, ARENAAX provides a comprehensive, graphical engineering toolset for application development.
ARENAAX includes built-in mobile support for some of the more commonly used features like property sheets, scheduling, alarm management and charting.
Features:
Provides access to alarms, logs, graphics, schedules, and configuration data with a standard web browser
FALCON plant controllers can be integrated free of charge, no 3rd party BACnet driver has to be used
Optional direct Ethernet based driver support for BACnet IP, OPC (Client), Modbus TCP, EIB/KNX IP and SNMP; additional point blocks for each driver may be purchased in blocks of 500 for each protocol
Certified BACnet drivers are available (OWS, AWS)
Java-enabled user interface (UI) which supports highly customizable dynamic graphics as well as a non-Java UI for browsers
Supports an unlimited number of users over the Internet / Intranet with a standard web browser, depending on the host PC
Optional Enterprise-level data archival using SQL, Oracle or DB2 database, and HTTP/HTML/XML text formats
'Audit Trail' of database changes, database storage and backup, global time functions, calendar, central scheduling, control, and energy management routines.
Sophisticated alarm processing and routing, including e-mail and SMS
Password protection and security using standard Java authentication and encryption techniques with optional security supported via an external LDAP connection
HTML-based help system that includes comprehensive on-line system documentation
Supports multiple HAWK stations connected to a local Ethernet network, or the Internet
A 'Small Building System' version is available for up to ten HAWKs


Model: ARENA AX Supervisor Software Small Building System, for up to 10 HAWK and 10 FALCON


CLAXARENASBSU1

Centraline Web based Supervisor software, ARENA AX
CL ARENA AX Upgrades

Upgrade CLAXARENASBS01 Small Building Supervisor 1 additional HAWK



CLAXARENASBSU5B

Centraline Web based Supervisor software, ARENA AX
CL ARENA AX Upgrades

upgrade SBS05 to SBS10



CLAXARENASBSUP

Centraline Web based Supervisor software, ARENA AX
CL ARENA AX Upgrades

Upgrade of ARENA AX Small Building Supervisor to full ARENA AX



CLAXARENASKYPE

Centraline Web based Supervisor software, ARENA AX
CL AX ARENA open system Drivers

Skype service for AX Supervisor (full or SBS10)



CLAXARENASMS

Centraline Web based Supervisor software, ARENA AX
CL AX ARENA open system Drivers

SMS Driver for ARENA AX



CLAXCOACH

Centraline HVAC and Integration controller, HAWK
COACH software

COACHAX for end users



CLAXCOACHSI

Centraline HVAC and Integration controller, HAWK
COACH software

COACHAX for system integrators (1 year license)



CLAXDBCSV

Centraline Web based Supervisor software, ARENA AX
CL AX Database Drivers

Database, CSV Server Driver



CLAXDBDB2

Centraline Web based Supervisor software, ARENA AX
CL AX Database Drivers

Database, DB2 Driver



CLAXDBMYSQL

Centraline Web based Supervisor software, ARENA AX
CL AX Database Drivers

Database, MySQL Driver



CLAXDBORCL

Centraline Web based Supervisor software, ARENA AX
CL AX Database Drivers

Database, Oracle Driver



CLAXDBSQL

Centraline Web based Supervisor software, ARENA AX
CL AX Database Drivers

Database, MS SQL Server Driver



CLAXDBTBL

Centraline Web based Supervisor software, ARENA AX
CL AX Database Drivers

Database, Table Driver



CLAXDRACX

Centraline HVAC and Integration controller, HAWK
System drivers

Andover AC256 Driver



CLAXDRAXI

Centraline HVAC and Integration controller, HAWK
Video drivers

Axis Video 4 Cameras driver



CLAXDRBAC500

Centraline Web based Supervisor software, ARENA AX
CL AX ARENA open system Drivers

Additional 500 BACnet points



CLAXDRBACAWS

Centraline Web based Supervisor software, ARENA AX
CL AX ARENA open system Drivers

Additional BACnet AWS feature for ARENA AX



CLAXDRBACEXP

Centraline Web based Supervisor software, ARENA AX
CL AX ARENA open system Drivers

Additional BACnet Server Export feature for ARENA AX



CLAXDRBACOWS

Centraline Web based Supervisor software, ARENA AX
CL AX ARENA open system Drivers

BACnet IP Driver, OWS certified, with 500 BACnet points



CLAXDRDED

Centraline HVAC and Integration controller, HAWK
Video drivers

Dedicated Micros DVR 4 Cameras driver



CLAXDREIB

Centraline Web based Supervisor software, ARENA AX
CL AX ARENA open system Drivers

EIB IP Driver with 500 EIB points



CLAXDREIB500

Centraline Web based Supervisor software, ARENA AX
CL AX ARENA open system Drivers

Additional 500 EIB points



CLAXDRFIDELIO

Centraline Web based Supervisor software, ARENA AX
CL AX ARENA open system Drivers

Fidelio Hotel booking system driver



CLAXDRFLX

Centraline HVAC and Integration controller, HAWK
System drivers

Flex Driver over R232 or RS485



CLAXDRGCIR

Centraline HVAC and Integration controller, HAWK
System drivers

Global Cache driver



CLAXDRGL1

Centraline HVAC and Integration controller, HAWK
System drivers

Honeywell Galaxy 1 Panel Driver



CLAXDRGLX

Centraline HVAC and Integration controller, HAWK
System drivers

Honeywell Galaxy Driver



CLAXDRHLV

Centraline HVAC and Integration controller, HAWK
System drivers

Helvar driver



CLAXDRHRSM

Centraline HVAC and Integration controller, HAWK
System drivers

Horstmann driver



CLAXDRHTR

Centraline HVAC and Integration controller, HAWK
System drivers

Hometronic Driver



CLAXDRINF

Centraline HVAC and Integration controller, HAWK
System drivers

Andover Infintity Continuum Driver



CLAXDRLONIP

Centraline Web based Supervisor software, ARENA AX
CL AX ARENA open system Drivers

LON IP Driver with 500 LON points



CLAXDRLONIP500

Centraline Web based Supervisor software, ARENA AX
CL AX ARENA open system Drivers

Additional 500 LON points



CLAXDRMBSIP

Centraline Web based Supervisor software, ARENA AX
CL AX ARENA open system Drivers

MBus IP Driver with 500 points



CLAXDRMBSIP500

Centraline Web based Supervisor software, ARENA AX
CL AX ARENA open system Drivers

Additional 500 MBus IP points



CLAXDRMIL

Centraline HVAC and Integration controller, HAWK
Video drivers

Milestone NVM 4 Cameras driver



CLAXDRMTCP

Centraline Web based Supervisor software, ARENA AX
CL AX ARENA open system Drivers

Modbus TCP Driver with 500 Modbus TCP points



CLAXDRMTCP500

Centraline Web based Supervisor software, ARENA AX
CL AX ARENA open system Drivers

Additional 500 Modbus TCP points



CLAXDROBX

Centraline Web based Supervisor software, ARENA AX
CL AX ARENA open system Drivers

OBIX Driver for non-Niagara point connectivity with 500 OBIX points



CLAXDROBX500

Centraline Web based Supervisor software, ARENA AX
CL AX ARENA open system Drivers

Additional 500 OBIX points



CLAXDROPC

Centraline Web based Supervisor software, ARENA AX
CL AX ARENA open system Drivers

OPC Driver with 500 OPC points



CLAXDROPC500

Centraline Web based Supervisor software, ARENA AX
CL AX ARENA open system Drivers

Additional 500 OPC points



CLAXDROPE

Centraline Web based Supervisor software, ARENA AX
CL AX ARENA open system Drivers

OPC Client alarm and event notification driver with 500 points



CLAXDROPE500

Centraline Web based Supervisor software, ARENA AX
CL AX ARENA open system Drivers

Additional 500 points for OPC alarm and event notification driver



CLAXDRPRO

Centraline HVAC and Integration controller, HAWK
System drivers

Protec fire panel driver



CLAXDRRSL

Centraline HVAC and Integration controller, HAWK
System drivers

Resol water heating controller driver



CLAXDRSMS

Centraline HVAC and Integration controller, HAWK
System drivers

SMS service for HAWK



CLAXDRSNMP

Centraline Web based Supervisor software, ARENA AX
CL AX ARENA open system Drivers

SNMP Driver with 500 SNMP points



CLAXDRSNMP500

Centraline Web based Supervisor software, ARENA AX
CL AX ARENA open system Drivers

Additional 500 SNMP points



CLAXDRTBL

Centraline HVAC and Integration controller, HAWK
System drivers

Table Driver



CLAXEH00ND100A

Centraline EAGLEHAWK Integrated Plant Control

BACnet-compliant heating, ventilation, air conditioning Building Controller. It runs the CentraLine Niagara framework, integrating all trades in a building.
Control software: Freely programmable with CentraLine COACH AX software
utilizes the CentraLine HVAC application library for maximum energy efficiency
Hardware inputs: Controllers available with 0, 14 or 26 onboard inputs/outputs
Panel-Bus input modules available for: measurement of temperature, relative humidity, pressure etc.; contact status from relays, thermostats; counters etc.
Hardware outputs: Controllers available with 0, 14 or 26 onboard inputs/outputs
Panel-Bus output modules available for: control devices like servomotors, switching devices like pumps, ventilators etc.
Operator panels: EAGLEHAWK is operated via a standard browser. By default, an integrated web-server provides all freely programmable operation pages for full browser-based operation
Through the consistent use of software standards, any PC platform can be used as an operator interface (client), including laptops, desktops PCs, or touch screen PCs for direct flush mounting into electrical panel doors (IP65)
For mobile devices, freely programmable web-pages can be made available
Management applications: ARENA AX
Bus system description: Standard BACnet/IP communication with other BACnet controllers and BACnet Front-Ends
FOX/IP and FOXS/IP (Secure FOX) communication with ARENA AX and other Niagara devices as HAWK
Standard BACnet MS/TP communication with other BACnet MS/TP devices via one or both onboard RS485 interfaces
Panel-bus for communication to Panel I/O modules via one or both onboard RS485 interfaces
LonWorks(R) bus with the external USB-LON interface adapter IF-LON. LonWorks(R) transceiver type FTT10A
M-Bus(R) via the onboard RS232 interface plus external M-Bus power supply adaptor (e.g. PW3, PW20, PW60)
Modbus RTU via one or both onboard RS485 interfaces Modbus TCP communication via the onboard Ethernet RJ45 interface
HTTP and HTTPS (secure HTTP) communication with webbrowsers
In addition to the protocols above, also other network drivers which are available within the Niagara system can be used with the EAGLEHAWK e.g. KNX via the onboard Ethernet interface
Mounting: in cabinets
in fuse boxes conforming with standard DIN43880, and having a slot height of max. 45 mm
in cabinet front doors (using accessory MVC-80-AC2)
on walls (using accessory MVC-80-AC1)
Protection class: IP20
Power supply: 19..29 Vac or 20..30 Vdc ; 9 VA
Real-time clock back-up with goldcap capacitor for 72 hours buffer
Use PW3, PW20 or PW60, for M-Bus interfacing

Controller
Product description: EAGLEHAWK controller including base license; 102 Panel-Bus points; 5 integrated devices, 25 integrated points


CLAXEH14ND100A

Centraline EAGLEHAWK Integrated Plant Control

BACnet-compliant heating, ventilation, air conditioning Building Controller. It runs the CentraLine Niagara framework, integrating all trades in a building.
Control software: Freely programmable with CentraLine COACH AX software
utilizes the CentraLine HVAC application library for maximum energy efficiency
Hardware inputs: Controllers available with 0, 14 or 26 onboard inputs/outputs
Panel-Bus input modules available for: measurement of temperature, relative humidity, pressure etc.; contact status from relays, thermostats; counters etc.
Hardware outputs: Controllers available with 0, 14 or 26 onboard inputs/outputs
Panel-Bus output modules available for: control devices like servomotors, switching devices like pumps, ventilators etc.
Operator panels: EAGLEHAWK is operated via a standard browser. By default, an integrated web-server provides all freely programmable operation pages for full browser-based operation
Through the consistent use of software standards, any PC platform can be used as an operator interface (client), including laptops, desktops PCs, or touch screen PCs for direct flush mounting into electrical panel doors (IP65)
For mobile devices, freely programmable web-pages can be made available
Management applications: ARENA AX
Bus system description: Standard BACnet/IP communication with other BACnet controllers and BACnet Front-Ends
FOX/IP and FOXS/IP (Secure FOX) communication with ARENA AX and other Niagara devices as HAWK
Standard BACnet MS/TP communication with other BACnet MS/TP devices via one or both onboard RS485 interfaces
Panel-bus for communication to Panel I/O modules via one or both onboard RS485 interfaces
LonWorks(R) bus with the external USB-LON interface adapter IF-LON. LonWorks(R) transceiver type FTT10A
M-Bus(R) via the onboard RS232 interface plus external M-Bus power supply adaptor (e.g. PW3, PW20, PW60)
Modbus RTU via one or both onboard RS485 interfaces Modbus TCP communication via the onboard Ethernet RJ45 interface
HTTP and HTTPS (secure HTTP) communication with webbrowsers
In addition to the protocols above, also other network drivers which are available within the Niagara system can be used with the EAGLEHAWK e.g. KNX via the onboard Ethernet interface
Mounting: in cabinets
in fuse boxes conforming with standard DIN43880, and having a slot height of max. 45 mm
in cabinet front doors (using accessory MVC-80-AC2)
on walls (using accessory MVC-80-AC1)
Protection class: IP20
Power supply: 19..29 Vac or 20..30 Vdc ; 9 VA
Real-time clock back-up with goldcap capacitor for 72 hours buffer
Use PW3, PW20 or PW60, for M-Bus interfacing

Controller
Product description: EAGLEHAWK controller with 14 onboard IO, including base license; 102 Panel-Bus / Onboard IO points; 5 integrated devices, 25 integrated points


CLAXEH26ND100A

Centraline EAGLEHAWK Integrated Plant Control

BACnet-compliant heating, ventilation, air conditioning Building Controller. It runs the CentraLine Niagara framework, integrating all trades in a building.
Control software: Freely programmable with CentraLine COACH AX software
utilizes the CentraLine HVAC application library for maximum energy efficiency
Hardware inputs: Controllers available with 0, 14 or 26 onboard inputs/outputs
Panel-Bus input modules available for: measurement of temperature, relative humidity, pressure etc.; contact status from relays, thermostats; counters etc.
Hardware outputs: Controllers available with 0, 14 or 26 onboard inputs/outputs
Panel-Bus output modules available for: control devices like servomotors, switching devices like pumps, ventilators etc.
Operator panels: EAGLEHAWK is operated via a standard browser. By default, an integrated web-server provides all freely programmable operation pages for full browser-based operation
Through the consistent use of software standards, any PC platform can be used as an operator interface (client), including laptops, desktops PCs, or touch screen PCs for direct flush mounting into electrical panel doors (IP65)
For mobile devices, freely programmable web-pages can be made available
Management applications: ARENA AX
Bus system description: Standard BACnet/IP communication with other BACnet controllers and BACnet Front-Ends
FOX/IP and FOXS/IP (Secure FOX) communication with ARENA AX and other Niagara devices as HAWK
Standard BACnet MS/TP communication with other BACnet MS/TP devices via one or both onboard RS485 interfaces
Panel-bus for communication to Panel I/O modules via one or both onboard RS485 interfaces
LonWorks(R) bus with the external USB-LON interface adapter IF-LON. LonWorks(R) transceiver type FTT10A
M-Bus(R) via the onboard RS232 interface plus external M-Bus power supply adaptor (e.g. PW3, PW20, PW60)
Modbus RTU via one or both onboard RS485 interfaces Modbus TCP communication via the onboard Ethernet RJ45 interface
HTTP and HTTPS (secure HTTP) communication with webbrowsers
In addition to the protocols above, also other network drivers which are available within the Niagara system can be used with the EAGLEHAWK e.g. KNX via the onboard Ethernet interface
Mounting: in cabinets
in fuse boxes conforming with standard DIN43880, and having a slot height of max. 45 mm
in cabinet front doors (using accessory MVC-80-AC2)
on walls (using accessory MVC-80-AC1)
Protection class: IP20
Power supply: 19..29 Vac or 20..30 Vdc ; 9 VA
Real-time clock back-up with goldcap capacitor for 72 hours buffer
Use PW3, PW20 or PW60, for M-Bus interfacing

Controller
Product description: EAGLEHAWK controller with 26 onboard IO, including base license; 102 Panel-Bus / Onboard IO points; 5 integrated devices, 25 integrated points


CLAXEH3PTY25UP

Centraline EAGLEHAWK Integrated Plant Control

BACnet-compliant heating, ventilation, air conditioning Building Controller. It runs the CentraLine Niagara framework, integrating all trades in a building.
Control software: Freely programmable with CentraLine COACH AX software
utilizes the CentraLine HVAC application library for maximum energy efficiency
Hardware inputs: Controllers available with 0, 14 or 26 onboard inputs/outputs
Panel-Bus input modules available for: measurement of temperature, relative humidity, pressure etc.; contact status from relays, thermostats; counters etc.
Hardware outputs: Controllers available with 0, 14 or 26 onboard inputs/outputs
Panel-Bus output modules available for: control devices like servomotors, switching devices like pumps, ventilators etc.
Operator panels: EAGLEHAWK is operated via a standard browser. By default, an integrated web-server provides all freely programmable operation pages for full browser-based operation
Through the consistent use of software standards, any PC platform can be used as an operator interface (client), including laptops, desktops PCs, or touch screen PCs for direct flush mounting into electrical panel doors (IP65)
For mobile devices, freely programmable web-pages can be made available
Management applications: ARENA AX
Bus system description: Standard BACnet/IP communication with other BACnet controllers and BACnet Front-Ends
FOX/IP and FOXS/IP (Secure FOX) communication with ARENA AX and other Niagara devices as HAWK
Standard BACnet MS/TP communication with other BACnet MS/TP devices via one or both onboard RS485 interfaces
Panel-bus for communication to Panel I/O modules via one or both onboard RS485 interfaces
LonWorks(R) bus with the external USB-LON interface adapter IF-LON. LonWorks(R) transceiver type FTT10A
M-Bus(R) via the onboard RS232 interface plus external M-Bus power supply adaptor (e.g. PW3, PW20, PW60)
Modbus RTU via one or both onboard RS485 interfaces Modbus TCP communication via the onboard Ethernet RJ45 interface
HTTP and HTTPS (secure HTTP) communication with webbrowsers
In addition to the protocols above, also other network drivers which are available within the Niagara system can be used with the EAGLEHAWK e.g. KNX via the onboard Ethernet interface
Mounting: in cabinets
in fuse boxes conforming with standard DIN43880, and having a slot height of max. 45 mm
in cabinet front doors (using accessory MVC-80-AC2)
on walls (using accessory MVC-80-AC1)
Protection class: IP20
Power supply: 19..29 Vac or 20..30 Vdc ; 9 VA
Real-time clock back-up with goldcap capacitor for 72 hours buffer
Use PW3, PW20 or PW60, for M-Bus interfacing

Controller
Product description: Additional 25 integrated points, 5 integrated devices


CLAXEHPB100UP

Centraline EAGLEHAWK Integrated Plant Control

BACnet-compliant heating, ventilation, air conditioning Building Controller. It runs the CentraLine Niagara framework, integrating all trades in a building.
Control software: Freely programmable with CentraLine COACH AX software
utilizes the CentraLine HVAC application library for maximum energy efficiency
Hardware inputs: Controllers available with 0, 14 or 26 onboard inputs/outputs
Panel-Bus input modules available for: measurement of temperature, relative humidity, pressure etc.; contact status from relays, thermostats; counters etc.
Hardware outputs: Controllers available with 0, 14 or 26 onboard inputs/outputs
Panel-Bus output modules available for: control devices like servomotors, switching devices like pumps, ventilators etc.
Operator panels: EAGLEHAWK is operated via a standard browser. By default, an integrated web-server provides all freely programmable operation pages for full browser-based operation
Through the consistent use of software standards, any PC platform can be used as an operator interface (client), including laptops, desktops PCs, or touch screen PCs for direct flush mounting into electrical panel doors (IP65)
For mobile devices, freely programmable web-pages can be made available
Management applications: ARENA AX
Bus system description: Standard BACnet/IP communication with other BACnet controllers and BACnet Front-Ends
FOX/IP and FOXS/IP (Secure FOX) communication with ARENA AX and other Niagara devices as HAWK
Standard BACnet MS/TP communication with other BACnet MS/TP devices via one or both onboard RS485 interfaces
Panel-bus for communication to Panel I/O modules via one or both onboard RS485 interfaces
LonWorks(R) bus with the external USB-LON interface adapter IF-LON. LonWorks(R) transceiver type FTT10A
M-Bus(R) via the onboard RS232 interface plus external M-Bus power supply adaptor (e.g. PW3, PW20, PW60)
Modbus RTU via one or both onboard RS485 interfaces Modbus TCP communication via the onboard Ethernet RJ45 interface
HTTP and HTTPS (secure HTTP) communication with webbrowsers
In addition to the protocols above, also other network drivers which are available within the Niagara system can be used with the EAGLEHAWK e.g. KNX via the onboard Ethernet interface
Mounting: in cabinets
in fuse boxes conforming with standard DIN43880, and having a slot height of max. 45 mm
in cabinet front doors (using accessory MVC-80-AC2)
on walls (using accessory MVC-80-AC1)
Protection class: IP20
Power supply: 19..29 Vac or 20..30 Vdc ; 9 VA
Real-time clock back-up with goldcap capacitor for 72 hours buffer
Use PW3, PW20 or PW60, for M-Bus interfacing

Controller
Product description: Additional 100 Panel-Bus points


CLAXEHRBAC150UP

Centraline EAGLEHAWK Integrated Plant Control

BACnet-compliant heating, ventilation, air conditioning Building Controller. It runs the CentraLine Niagara framework, integrating all trades in a building.
Control software: Freely programmable with CentraLine COACH AX software
utilizes the CentraLine HVAC application library for maximum energy efficiency
Hardware inputs: Controllers available with 0, 14 or 26 onboard inputs/outputs
Panel-Bus input modules available for: measurement of temperature, relative humidity, pressure etc.; contact status from relays, thermostats; counters etc.
Hardware outputs: Controllers available with 0, 14 or 26 onboard inputs/outputs
Panel-Bus output modules available for: control devices like servomotors, switching devices like pumps, ventilators etc.
Operator panels: EAGLEHAWK is operated via a standard browser. By default, an integrated web-server provides all freely programmable operation pages for full browser-based operation
Through the consistent use of software standards, any PC platform can be used as an operator interface (client), including laptops, desktops PCs, or touch screen PCs for direct flush mounting into electrical panel doors (IP65)
For mobile devices, freely programmable web-pages can be made available
Management applications: ARENA AX
Bus system description: Standard BACnet/IP communication with other BACnet controllers and BACnet Front-Ends
FOX/IP and FOXS/IP (Secure FOX) communication with ARENA AX and other Niagara devices as HAWK
Standard BACnet MS/TP communication with other BACnet MS/TP devices via one or both onboard RS485 interfaces
Panel-bus for communication to Panel I/O modules via one or both onboard RS485 interfaces
LonWorks(R) bus with the external USB-LON interface adapter IF-LON. LonWorks(R) transceiver type FTT10A
M-Bus(R) via the onboard RS232 interface plus external M-Bus power supply adaptor (e.g. PW3, PW20, PW60)
Modbus RTU via one or both onboard RS485 interfaces Modbus TCP communication via the onboard Ethernet RJ45 interface
HTTP and HTTPS (secure HTTP) communication with webbrowsers
In addition to the protocols above, also other network drivers which are available within the Niagara system can be used with the EAGLEHAWK e.g. KNX via the onboard Ethernet interface
Mounting: in cabinets
in fuse boxes conforming with standard DIN43880, and having a slot height of max. 45 mm
in cabinet front doors (using accessory MVC-80-AC2)
on walls (using accessory MVC-80-AC1)
Protection class: IP20
Power supply: 19..29 Vac or 20..30 Vdc ; 9 VA
Real-time clock back-up with goldcap capacitor for 72 hours buffer
Use PW3, PW20 or PW60, for M-Bus interfacing

Controller
Product description: 150 BACnet room integration points for Honeywell room controllers


CLAXEHRLON150UP

Centraline EAGLEHAWK Integrated Plant Control

BACnet-compliant heating, ventilation, air conditioning Building Controller. It runs the CentraLine Niagara framework, integrating all trades in a building.
Control software: Freely programmable with CentraLine COACH AX software
utilizes the CentraLine HVAC application library for maximum energy efficiency
Hardware inputs: Controllers available with 0, 14 or 26 onboard inputs/outputs
Panel-Bus input modules available for: measurement of temperature, relative humidity, pressure etc.; contact status from relays, thermostats; counters etc.
Hardware outputs: Controllers available with 0, 14 or 26 onboard inputs/outputs
Panel-Bus output modules available for: control devices like servomotors, switching devices like pumps, ventilators etc.
Operator panels: EAGLEHAWK is operated via a standard browser. By default, an integrated web-server provides all freely programmable operation pages for full browser-based operation
Through the consistent use of software standards, any PC platform can be used as an operator interface (client), including laptops, desktops PCs, or touch screen PCs for direct flush mounting into electrical panel doors (IP65)
For mobile devices, freely programmable web-pages can be made available
Management applications: ARENA AX
Bus system description: Standard BACnet/IP communication with other BACnet controllers and BACnet Front-Ends
FOX/IP and FOXS/IP (Secure FOX) communication with ARENA AX and other Niagara devices as HAWK
Standard BACnet MS/TP communication with other BACnet MS/TP devices via one or both onboard RS485 interfaces
Panel-bus for communication to Panel I/O modules via one or both onboard RS485 interfaces
LonWorks(R) bus with the external USB-LON interface adapter IF-LON. LonWorks(R) transceiver type FTT10A
M-Bus(R) via the onboard RS232 interface plus external M-Bus power supply adaptor (e.g. PW3, PW20, PW60)
Modbus RTU via one or both onboard RS485 interfaces Modbus TCP communication via the onboard Ethernet RJ45 interface
HTTP and HTTPS (secure HTTP) communication with webbrowsers
In addition to the protocols above, also other network drivers which are available within the Niagara system can be used with the EAGLEHAWK e.g. KNX via the onboard Ethernet interface
Mounting: in cabinets
in fuse boxes conforming with standard DIN43880, and having a slot height of max. 45 mm
in cabinet front doors (using accessory MVC-80-AC2)
on walls (using accessory MVC-80-AC1)
Protection class: IP20
Power supply: 19..29 Vac or 20..30 Vdc ; 9 VA
Real-time clock back-up with goldcap capacitor for 72 hours buffer
Use PW3, PW20 or PW60, for M-Bus interfacing

Controller
Product description: 150 LON room integration points for Honeywell room controllers


CLAXHAWK220

Centraline HVAC and Integration controller, HAWK

The HAWK is a compact controller for integration of Heating, Ventilation, Air Conditioning (HVAC) systems and non-HVAC systems (e.g. Lighting) in a building. It combines integrated control, supervision, data logging, alarming, scheduling and network management functions with Internet connectivity and web serving capabilities in a small, compact platform. The HAWK makes it possible to control and manage external devices over the Internet and presents real time information to users in web-based graphical views. It facilitates efficient project planning and smart engineering opportunities for small to large size integration projects.
Hardware inputs/outputs
CentraLine LON I/O modules (CLIOL)
external I/O modules with universal inputs and outputs for: measurement of temperature, relative humidity, pressure, etc.; and contact status from relays, thermostats etc. and control devices like servomotors; and relay outputs for pumps, ventilators etc.
Integration
Open Systems, all Modbus types, BACnet IP and MSTP, LON (via optional plug-in card), EIB/KNX IP, M-bus, oBiX, and SNMP
See also System drivers part
Communication cards
2 expansion slots available for extra communication cards (LON, RS232, RS485, GPRS)
M2M models have 1 expansion slot
Web server
Supports most common browsers
Different profiles are supported, profiles where Java plugin is needed but also profiles where only HTML is required
Mobile device support via HTML 5, iOS, Adroid...
Control software: free programmable with COACHAX
Management applications: ARENAAX
Stand-alone operation: yes
Mounting: DIN rail or wall mounting

HAWK 200
Product description: HAWK 220, Java heap memory 16 MB; max. 400kRU, 8 devices/network, 34 points NDIO, max one additional Network, max 100 points per network


CLAXHAWK22UP23

Centraline HVAC and Integration controller, HAWK
HAWK 200 upgrades

Upgrade HAWK 220 to 230



CLAXHAWK230

Centraline HVAC and Integration controller, HAWK

The HAWK is a compact controller for integration of Heating, Ventilation, Air Conditioning (HVAC) systems and non-HVAC systems (e.g. Lighting) in a building. It combines integrated control, supervision, data logging, alarming, scheduling and network management functions with Internet connectivity and web serving capabilities in a small, compact platform. The HAWK makes it possible to control and manage external devices over the Internet and presents real time information to users in web-based graphical views. It facilitates efficient project planning and smart engineering opportunities for small to large size integration projects.
Hardware inputs/outputs
CentraLine LON I/O modules (CLIOL)
external I/O modules with universal inputs and outputs for: measurement of temperature, relative humidity, pressure, etc.; and contact status from relays, thermostats etc. and control devices like servomotors; and relay outputs for pumps, ventilators etc.
Integration
Open Systems, all Modbus types, BACnet IP and MSTP, LON (via optional plug-in card), EIB/KNX IP, M-bus, oBiX, and SNMP
See also System drivers part
Communication cards
2 expansion slots available for extra communication cards (LON, RS232, RS485, GPRS)
M2M models have 1 expansion slot
Web server
Supports most common browsers
Different profiles are supported, profiles where Java plugin is needed but also profiles where only HTML is required
Mobile device support via HTML 5, iOS, Adroid...
Control software: free programmable with COACHAX
Management applications: ARENAAX
Stand-alone operation: yes
Mounting: DIN rail or wall mounting

HAWK 200
Product description: HAWK 230, Java heap memory 16 MB; max. 450kRU, 200 (EIB 500) points/network


CLAXHAWK23UP24

Centraline HVAC and Integration controller, HAWK
HAWK 200 upgrades

Upgrade HAWK 230 to 240



CLAXHAWK240

Centraline HVAC and Integration controller, HAWK

The HAWK is a compact controller for integration of Heating, Ventilation, Air Conditioning (HVAC) systems and non-HVAC systems (e.g. Lighting) in a building. It combines integrated control, supervision, data logging, alarming, scheduling and network management functions with Internet connectivity and web serving capabilities in a small, compact platform. The HAWK makes it possible to control and manage external devices over the Internet and presents real time information to users in web-based graphical views. It facilitates efficient project planning and smart engineering opportunities for small to large size integration projects.
Hardware inputs/outputs
CentraLine LON I/O modules (CLIOL)
external I/O modules with universal inputs and outputs for: measurement of temperature, relative humidity, pressure, etc.; and contact status from relays, thermostats etc. and control devices like servomotors; and relay outputs for pumps, ventilators etc.
Integration
Open Systems, all Modbus types, BACnet IP and MSTP, LON (via optional plug-in card), EIB/KNX IP, M-bus, oBiX, and SNMP
See also System drivers part
Communication cards
2 expansion slots available for extra communication cards (LON, RS232, RS485, GPRS)
M2M models have 1 expansion slot
Web server
Supports most common browsers
Different profiles are supported, profiles where Java plugin is needed but also profiles where only HTML is required
Mobile device support via HTML 5, iOS, Adroid...
Control software: free programmable with COACHAX
Management applications: ARENAAX
Stand-alone operation: yes
Mounting: DIN rail or wall mounting

HAWK 200
Product description: HAWK 240, Java heap memory 16 MB


CLAXHAWK24UP25

Centraline HVAC and Integration controller, HAWK
HAWK 200 upgrades

Upgrade HAWK 240 to 250



CLAXHAWK250

Centraline HVAC and Integration controller, HAWK

The HAWK is a compact controller for integration of Heating, Ventilation, Air Conditioning (HVAC) systems and non-HVAC systems (e.g. Lighting) in a building. It combines integrated control, supervision, data logging, alarming, scheduling and network management functions with Internet connectivity and web serving capabilities in a small, compact platform. The HAWK makes it possible to control and manage external devices over the Internet and presents real time information to users in web-based graphical views. It facilitates efficient project planning and smart engineering opportunities for small to large size integration projects.
Hardware inputs/outputs
CentraLine LON I/O modules (CLIOL)
external I/O modules with universal inputs and outputs for: measurement of temperature, relative humidity, pressure, etc.; and contact status from relays, thermostats etc. and control devices like servomotors; and relay outputs for pumps, ventilators etc.
Integration
Open Systems, all Modbus types, BACnet IP and MSTP, LON (via optional plug-in card), EIB/KNX IP, M-bus, oBiX, and SNMP
See also System drivers part
Communication cards
2 expansion slots available for extra communication cards (LON, RS232, RS485, GPRS)
M2M models have 1 expansion slot
Web server
Supports most common browsers
Different profiles are supported, profiles where Java plugin is needed but also profiles where only HTML is required
Mobile device support via HTML 5, iOS, Adroid...
Control software: free programmable with COACHAX
Management applications: ARENAAX
Stand-alone operation: yes
Mounting: DIN rail or wall mounting

HAWK 200
Product description: HAWK 250, Java heap memory 48 MB


CLAXHAWK320E

Centraline HVAC and Integration controller, HAWK

The HAWK is a compact controller for integration of Heating, Ventilation, Air Conditioning (HVAC) systems and non-HVAC systems (e.g. Lighting) in a building. It combines integrated control, supervision, data logging, alarming, scheduling and network management functions with Internet connectivity and web serving capabilities in a small, compact platform. The HAWK makes it possible to control and manage external devices over the Internet and presents real time information to users in web-based graphical views. It facilitates efficient project planning and smart engineering opportunities for small to large size integration projects.
Hardware inputs/outputs
CentraLine LON I/O modules (CLIOL)
external I/O modules with universal inputs and outputs for: measurement of temperature, relative humidity, pressure, etc.; and contact status from relays, thermostats etc. and control devices like servomotors; and relay outputs for pumps, ventilators etc.
Integration
Open Systems, all Modbus types, BACnet IP and MSTP, LON (via optional plug-in card), EIB/KNX IP, M-bus, oBiX, and SNMP
See also System drivers part
Communication cards
2 expansion slots available for extra communication cards (LON, RS232, RS485, GPRS)
M2M models have 1 expansion slot
Web server
Supports most common browsers
Different profiles are supported, profiles where Java plugin is needed but also profiles where only HTML is required
Mobile device support via HTML 5, iOS, Adroid...
Control software: free programmable with COACHAX
Management applications: ARENAAX
Stand-alone operation: yes
Mounting: DIN rail or wall mounting

HAWK 300E
Product description: HAWK 320, Java heap memory 24 MB; max. 400kRU, 8 devices/network, 34 points NDIO, max one additional Network, max 100 points per network


CLAXHAWK330E

Centraline HVAC and Integration controller, HAWK

The HAWK is a compact controller for integration of Heating, Ventilation, Air Conditioning (HVAC) systems and non-HVAC systems (e.g. Lighting) in a building. It combines integrated control, supervision, data logging, alarming, scheduling and network management functions with Internet connectivity and web serving capabilities in a small, compact platform. The HAWK makes it possible to control and manage external devices over the Internet and presents real time information to users in web-based graphical views. It facilitates efficient project planning and smart engineering opportunities for small to large size integration projects.
Hardware inputs/outputs
CentraLine LON I/O modules (CLIOL)
external I/O modules with universal inputs and outputs for: measurement of temperature, relative humidity, pressure, etc.; and contact status from relays, thermostats etc. and control devices like servomotors; and relay outputs for pumps, ventilators etc.
Integration
Open Systems, all Modbus types, BACnet IP and MSTP, LON (via optional plug-in card), EIB/KNX IP, M-bus, oBiX, and SNMP
See also System drivers part
Communication cards
2 expansion slots available for extra communication cards (LON, RS232, RS485, GPRS)
M2M models have 1 expansion slot
Web server
Supports most common browsers
Different profiles are supported, profiles where Java plugin is needed but also profiles where only HTML is required
Mobile device support via HTML 5, iOS, Adroid...
Control software: free programmable with COACHAX
Management applications: ARENAAX
Stand-alone operation: yes
Mounting: DIN rail or wall mounting

HAWK 300E
Product description: HAWK 330, Java heap memory 24 MB; max. 500kRU, 200 (EIB 500) points/network


CLAXHAWK340E

Centraline HVAC and Integration controller, HAWK

The HAWK is a compact controller for integration of Heating, Ventilation, Air Conditioning (HVAC) systems and non-HVAC systems (e.g. Lighting) in a building. It combines integrated control, supervision, data logging, alarming, scheduling and network management functions with Internet connectivity and web serving capabilities in a small, compact platform. The HAWK makes it possible to control and manage external devices over the Internet and presents real time information to users in web-based graphical views. It facilitates efficient project planning and smart engineering opportunities for small to large size integration projects.
Hardware inputs/outputs
CentraLine LON I/O modules (CLIOL)
external I/O modules with universal inputs and outputs for: measurement of temperature, relative humidity, pressure, etc.; and contact status from relays, thermostats etc. and control devices like servomotors; and relay outputs for pumps, ventilators etc.
Integration
Open Systems, all Modbus types, BACnet IP and MSTP, LON (via optional plug-in card), EIB/KNX IP, M-bus, oBiX, and SNMP
See also System drivers part
Communication cards
2 expansion slots available for extra communication cards (LON, RS232, RS485, GPRS)
M2M models have 1 expansion slot
Web server
Supports most common browsers
Different profiles are supported, profiles where Java plugin is needed but also profiles where only HTML is required
Mobile device support via HTML 5, iOS, Adroid...
Control software: free programmable with COACHAX
Management applications: ARENAAX
Stand-alone operation: yes
Mounting: DIN rail or wall mounting

HAWK 300E
Product description: HAWK 340, Java heap memory 24 MB


CLAXHAWK350E

Centraline HVAC and Integration controller, HAWK

The HAWK is a compact controller for integration of Heating, Ventilation, Air Conditioning (HVAC) systems and non-HVAC systems (e.g. Lighting) in a building. It combines integrated control, supervision, data logging, alarming, scheduling and network management functions with Internet connectivity and web serving capabilities in a small, compact platform. The HAWK makes it possible to control and manage external devices over the Internet and presents real time information to users in web-based graphical views. It facilitates efficient project planning and smart engineering opportunities for small to large size integration projects.
Hardware inputs/outputs
CentraLine LON I/O modules (CLIOL)
external I/O modules with universal inputs and outputs for: measurement of temperature, relative humidity, pressure, etc.; and contact status from relays, thermostats etc. and control devices like servomotors; and relay outputs for pumps, ventilators etc.
Integration
Open Systems, all Modbus types, BACnet IP and MSTP, LON (via optional plug-in card), EIB/KNX IP, M-bus, oBiX, and SNMP
See also System drivers part
Communication cards
2 expansion slots available for extra communication cards (LON, RS232, RS485, GPRS)
M2M models have 1 expansion slot
Web server
Supports most common browsers
Different profiles are supported, profiles where Java plugin is needed but also profiles where only HTML is required
Mobile device support via HTML 5, iOS, Adroid...
Control software: free programmable with COACHAX
Management applications: ARENAAX
Stand-alone operation: yes
Mounting: DIN rail or wall mounting

HAWK 300E
Product description: HAWK 350, Java heap memory 96 MB


CLAXHAWK630E

Centraline HVAC and Integration controller, HAWK

The HAWK is a compact controller for integration of Heating, Ventilation, Air Conditioning (HVAC) systems and non-HVAC systems (e.g. Lighting) in a building. It combines integrated control, supervision, data logging, alarming, scheduling and network management functions with Internet connectivity and web serving capabilities in a small, compact platform. The HAWK makes it possible to control and manage external devices over the Internet and presents real time information to users in web-based graphical views. It facilitates efficient project planning and smart engineering opportunities for small to large size integration projects.
Hardware inputs/outputs
CentraLine LON I/O modules (CLIOL)
external I/O modules with universal inputs and outputs for: measurement of temperature, relative humidity, pressure, etc.; and contact status from relays, thermostats etc. and control devices like servomotors; and relay outputs for pumps, ventilators etc.
Integration
Open Systems, all Modbus types, BACnet IP and MSTP, LON (via optional plug-in card), EIB/KNX IP, M-bus, oBiX, and SNMP
See also System drivers part
Communication cards
2 expansion slots available for extra communication cards (LON, RS232, RS485, GPRS)
M2M models have 1 expansion slot
Web server
Supports most common browsers
Different profiles are supported, profiles where Java plugin is needed but also profiles where only HTML is required
Mobile device support via HTML 5, iOS, Adroid...
Control software: free programmable with COACHAX
Management applications: ARENAAX
Stand-alone operation: yes
Mounting: DIN rail or wall mounting

HAWK 600E, without battery
Product description: HAWK 630, Java heap memory 48 MB, resource count max 450kRU, drivers max 200 points (EIB/KNX 500 points)


CLAXHAWK63UP64

Centraline HVAC and Integration controller, HAWK
HAWK 600 upgrades

Upgrade HAWK 630 to 640



CLAXHAWK63UP64E

Centraline HVAC and Integration controller, HAWK
HAWK 600E upgrades

Upgrade HAWK 630 to 640



CLAXHAWK640E

Centraline HVAC and Integration controller, HAWK

The HAWK is a compact controller for integration of Heating, Ventilation, Air Conditioning (HVAC) systems and non-HVAC systems (e.g. Lighting) in a building. It combines integrated control, supervision, data logging, alarming, scheduling and network management functions with Internet connectivity and web serving capabilities in a small, compact platform. The HAWK makes it possible to control and manage external devices over the Internet and presents real time information to users in web-based graphical views. It facilitates efficient project planning and smart engineering opportunities for small to large size integration projects.
Hardware inputs/outputs
CentraLine LON I/O modules (CLIOL)
external I/O modules with universal inputs and outputs for: measurement of temperature, relative humidity, pressure, etc.; and contact status from relays, thermostats etc. and control devices like servomotors; and relay outputs for pumps, ventilators etc.
Integration
Open Systems, all Modbus types, BACnet IP and MSTP, LON (via optional plug-in card), EIB/KNX IP, M-bus, oBiX, and SNMP
See also System drivers part
Communication cards
2 expansion slots available for extra communication cards (LON, RS232, RS485, GPRS)
M2M models have 1 expansion slot
Web server
Supports most common browsers
Different profiles are supported, profiles where Java plugin is needed but also profiles where only HTML is required
Mobile device support via HTML 5, iOS, Adroid...
Control software: free programmable with COACHAX
Management applications: ARENAAX
Stand-alone operation: yes
Mounting: DIN rail or wall mounting

HAWK 600E, without battery
Product description: HAWK 640, Java heap memory 48 MB, resource count max 1000kRU


CLAXHAWK64UP65

Centraline HVAC and Integration controller, HAWK
HAWK 600 upgrades

Upgrade HAWK 640 to 650



CLAXHAWK64UP65E

Centraline HVAC and Integration controller, HAWK
HAWK 600E upgrades

Upgrade HAWK 640 to 650



CLAXHAWK650E

Centraline HVAC and Integration controller, HAWK

The HAWK is a compact controller for integration of Heating, Ventilation, Air Conditioning (HVAC) systems and non-HVAC systems (e.g. Lighting) in a building. It combines integrated control, supervision, data logging, alarming, scheduling and network management functions with Internet connectivity and web serving capabilities in a small, compact platform. The HAWK makes it possible to control and manage external devices over the Internet and presents real time information to users in web-based graphical views. It facilitates efficient project planning and smart engineering opportunities for small to large size integration projects.
Hardware inputs/outputs
CentraLine LON I/O modules (CLIOL)
external I/O modules with universal inputs and outputs for: measurement of temperature, relative humidity, pressure, etc.; and contact status from relays, thermostats etc. and control devices like servomotors; and relay outputs for pumps, ventilators etc.
Integration
Open Systems, all Modbus types, BACnet IP and MSTP, LON (via optional plug-in card), EIB/KNX IP, M-bus, oBiX, and SNMP
See also System drivers part
Communication cards
2 expansion slots available for extra communication cards (LON, RS232, RS485, GPRS)
M2M models have 1 expansion slot
Web server
Supports most common browsers
Different profiles are supported, profiles where Java plugin is needed but also profiles where only HTML is required
Mobile device support via HTML 5, iOS, Adroid...
Control software: free programmable with COACHAX
Management applications: ARENAAX
Stand-alone operation: yes
Mounting: DIN rail or wall mounting

HAWK 600E, without battery
Product description: HAWK 650, Java heap memory 48 MB


CLAXHAWK65UP66

Centraline HVAC and Integration controller, HAWK
HAWK 600 upgrades

Upgrade HAWK 650 to 660



CLAXHAWK65UP66E

Centraline HVAC and Integration controller, HAWK
HAWK 600E upgrades

Upgrade HAWK 650 to 660



CLAXHAWK660E

Centraline HVAC and Integration controller, HAWK

The HAWK is a compact controller for integration of Heating, Ventilation, Air Conditioning (HVAC) systems and non-HVAC systems (e.g. Lighting) in a building. It combines integrated control, supervision, data logging, alarming, scheduling and network management functions with Internet connectivity and web serving capabilities in a small, compact platform. The HAWK makes it possible to control and manage external devices over the Internet and presents real time information to users in web-based graphical views. It facilitates efficient project planning and smart engineering opportunities for small to large size integration projects.
Hardware inputs/outputs
CentraLine LON I/O modules (CLIOL)
external I/O modules with universal inputs and outputs for: measurement of temperature, relative humidity, pressure, etc.; and contact status from relays, thermostats etc. and control devices like servomotors; and relay outputs for pumps, ventilators etc.
Integration
Open Systems, all Modbus types, BACnet IP and MSTP, LON (via optional plug-in card), EIB/KNX IP, M-bus, oBiX, and SNMP
See also System drivers part
Communication cards
2 expansion slots available for extra communication cards (LON, RS232, RS485, GPRS)
M2M models have 1 expansion slot
Web server
Supports most common browsers
Different profiles are supported, profiles where Java plugin is needed but also profiles where only HTML is required
Mobile device support via HTML 5, iOS, Adroid...
Control software: free programmable with COACHAX
Management applications: ARENAAX
Stand-alone operation: yes
Mounting: DIN rail or wall mounting

HAWK 600E, without battery
Product description: HAWK 660, Java heap memory 96 MB


CLAXHAWKBAT

Centraline HVAC and Integration controller, HAWK
Power supply for 1 HAWK module (not for M2M)

Replacement Battery for Series HAWK 200 and 600



CLAXHAWKIF232

Centraline HVAC and Integration controller, HAWK
Communication cards, for expansion slots

RS-232 adapter



CLAXHAWKIF485

Centraline HVAC and Integration controller, HAWK
Communication cards, for expansion slots

2 x RS-485 adapter



CLAXHAWKIFLON

Centraline HVAC and Integration controller, HAWK
Communication cards, for expansion slots

LON adapter



CLAXHAWKIO16

Centraline HVAC and Integration controller, HAWK
DIN-rail I/O modules; max. 4xIO16 or 2xIO16 + 1xIO34 (not for M2M)

8 universal inputs, 4 relay outputs, 4 0..10 Vdc analog output



CLAXHAWKIO34

Centraline HVAC and Integration controller, HAWK
DIN-rail I/O modules; max. 4xIO16 or 2xIO16 + 1xIO34 (not for M2M)

16 universal inputs, 10 relay outputs, 8 0..10 Vdc analog output; note: this module includes an on-board 24 Vac/dc power supply



CLAXHAWKRUP

Centraline HVAC and Integration controller, HAWK
HAWK revision upgrade

Upgrade of HAWK and associated drivers, upgrade to latest revision



CLAXIFGPRS

Centraline HVAC and Integration controller, HAWK
Interface card GPRS (not for M2M)

GPRS adapter for HAWK 2/6 series, use one of the communication slots



CLAXIFGPRSACC

Centraline HVAC and Integration controller, HAWK
Interface card GPRS (not for M2M)

External antenna and bracket for GPRS modem



CLAXNPBPWR

Centraline HVAC and Integration controller, HAWK
Power supply for 1 HAWK module (not for M2M)

Power supply module, input 24 Vac/dc, DIN rail mounting



CLAXNPBPWR230

Centraline HVAC and Integration controller, HAWK
Power supply for 1 HAWK module (not for M2M)

Power supply module, input 230 Vac 50/60 Hz, DIN rail mounting



CLAXWPMEU

Centraline HVAC and Integration controller, HAWK
Power supply for 1 HAWK module (not for M2M)

Wall adapter, input 100..240 Vac, 50/60 Hz, European plug



CLAXWPMUK

Centraline HVAC and Integration controller, HAWK
Power supply for 1 HAWK module (not for M2M)

Wall adapter, input 100..240 Vac, 50/60 Hz, UK plug



CLCH2EL1

Centraline HVAC controller with configurable applications, and relay outputs, TIGER
COACH for selection of control software

COACH for End user



CLCH2EL2

Centraline HVAC controller with configurable applications, and relay outputs, TIGER
COACH for selection of control software

COACH for Expert End user



CLCH2EL3

Centraline HVAC controller with configurable applications, and relay outputs, TIGER
COACH for selection of control software

COACH for Partner



CLCH2EL4

Centraline HVAC controller with configurable applications, and relay outputs, TIGER
COACH for selection of control software

COACH for Expert Partner



CLCH3EL4

Centraline HVAC controller with configurable applications, PANTHER
COACH for selection of control software, downloadable from CentraLine partner web

COACH for Expert Partner



CLCM1C155A

Centraline CentraLine room temperature/ CO2 sensor

For sensing or controlling of CO2 concentration; and temperature measurement in buildings.
Protection class: IP30
Output signal: the following CO2 output signals are applicable, analog or digital
0..10V for 0..2000 ppm (factory setting)
0..10 V or 2..10 V for 0..2000 ppm or 0..3000 ppm (configurable)
Temperature element: NTC20k
Power supply: 24Vacdc
Mounting place: internal wall
Housing (HxWxD): 104mm|104mm|33mm


Temperature range: no
Setpoint knob: no
Extra setp. knob: no
Occupancy switch: no
Wiring terminals: 3
LED functions: CO2 indicator


CLCM1H112

Centraline CentraLine room temperature/R.H. sensor

Protection class: IP30
central override of setpoint
Temperature element: NTC20k
Temperature range: 6...40C
R.H. range: 20...95%rh
R.H. sensing element: capacitive
R.H. output signal: 0..10V=
Power supply: 24Vacdc
Mounting place: internal wall
Housing (HxWxD): 104mm|104mm|33mm
Wiring terminals: 4


CLCM1T11N

Centraline CentraLine room temperature sensors

Protection class: IP30
Temperature element: NTC20k
Mounting place: internal wall
Housing (HxWxD): 104mm|104mm|33mm


Temperature range: 6...40C
Setpoint knob: no
Extra setp. knob: no
Occupancy switch: no
Fan switch: no
Wiring terminals: 2
LED functions: no
Note: no


CLCM2T11N

Centraline CentraLine room temperature sensors

Protection class: IP30
Temperature element: NTC20k
Mounting place: internal wall
Housing (HxWxD): 104mm|104mm|33mm


Temperature range: 6...40C
Setpoint knob: -5...5K
Extra setp. knob: 12...30C
Occupancy switch: no
Fan switch: no
Wiring terminals: 3
LED functions: no
Note: no


CLCM3T111

Centraline CentraLine room temperature sensors

Protection class: IP30
Temperature element: NTC20k
Mounting place: internal wall
Housing (HxWxD): 104mm|104mm|33mm


Temperature range: -15...40C
Setpoint knob: -7...7K
Extra setp. knob: no
Occupancy switch: auto/off/on
Fan switch: no
Wiring terminals: 5
LED functions: error indication
Note: not for SERVAL


CLCM4C155A

Centraline CentraLine room temperature/ CO2 sensor

For sensing or controlling of CO2 concentration; and temperature measurement in buildings.
Protection class: IP30
Output signal: the following CO2 output signals are applicable, analog or digital
0..10V for 0..2000 ppm (factory setting)
0..10 V or 2..10 V for 0..2000 ppm or 0..3000 ppm (configurable)
Temperature element: NTC20k
Power supply: 24Vacdc
Mounting place: internal wall
Housing (HxWxD): 104mm|104mm|33mm


Temperature range: 6...40C
Setpoint knob: -5...5K
Extra setp. knob: 12...30C
Occupancy switch: auto/bypass
Wiring terminals: 7
LED functions: occupancy


CLCM4T111

Centraline CentraLine room temperature sensors

Protection class: IP30
Temperature element: NTC20k
Mounting place: internal wall
Housing (HxWxD): 104mm|104mm|33mm


Temperature range: 6...40C
Setpoint knob: -5...5K
Extra setp. knob: 12...30C
Occupancy switch: auto/bypass
Fan switch: no
Wiring terminals: 7
LED functions: no
Note: no


CLCM5T111

Centraline CentraLine room temperature sensors

Protection class: IP30
Temperature element: NTC20k
Mounting place: internal wall
Housing (HxWxD): 104mm|104mm|33mm


Temperature range: 6...40C
Setpoint knob: -5...5K
Extra setp. knob: 12...30C
Occupancy switch: auto/bypass
Fan switch: auto/off/on
Wiring terminals: 7
LED functions: no
Note: no


CLCM6H212

Centraline CentraLine room temperature/R.H. sensor, with display

Room temperature sensor with digital display. Model with R.H.-sensor.
Display functions: room temperature, setpoint temperature, occupancy status, fan speed status, humidity
Protection class: IP30
Tool-free configuration:
number of fan speeds
relative / absolute setpoint
enable/disable space temperature display
central override of setpoint and fan speed
Temperature element: NTC20k
Temperature range: 6...40C
Setpoint knob: -5...5K
Extra setp. knob: 12...30C
Occupancy switch: on/off
Fan switch: auto/off/1/2/3
Power supply: 24Vac
Mounting place: internal wall
Housing (HxWxD): 104mm|104mm|33mm


R.H. range: 10/15/20...95%rh
R.H. sensing element: capacitive
R.H. output signal: 0..10V=
Wiring terminals: 8


CLCM6T111

Centraline CentraLine room temperature sensors

Protection class: IP30
Temperature element: NTC20k
Mounting place: internal wall
Housing (HxWxD): 104mm|104mm|33mm


Temperature range: 6...40C
Setpoint knob: -5...5K
Extra setp. knob: 12...30C
Occupancy switch: auto/bypass
Fan switch: auto/off/1/2/3
Wiring terminals: 7
LED functions: no
Note: no


CLCM6T21N

Centraline CentraLine room temperature/R.H. sensor, with display

Room temperature sensor with digital display. Model with R.H.-sensor.
Display functions: room temperature, setpoint temperature, occupancy status, fan speed status, humidity
Protection class: IP30
Tool-free configuration:
number of fan speeds
relative / absolute setpoint
enable/disable space temperature display
central override of setpoint and fan speed
Temperature element: NTC20k
Temperature range: 6...40C
Setpoint knob: -5...5K
Extra setp. knob: 12...30C
Occupancy switch: on/off
Fan switch: auto/off/1/2/3
Power supply: 24Vac
Mounting place: internal wall
Housing (HxWxD): 104mm|104mm|33mm


R.H. range: no
R.H. sensing element: no
R.H. output signal: no
Wiring terminals: 7


CLCMNA172B

Centraline CentraLine air quality sensor

For detection of unpleasant odours, tobacco smoke, and vapours emitted by such materials as furniture, carpets, paint, glue, etc.
Protection class: IP30
Output signal: 0..10Vdc
Adjustable output offset.
Power supply: 24Vacdc
Mounting place: internal wall
Housing (HxWxD): 104mm|104mm|33mm
LED functions: air quality indication


CLCMTR40

Centraline Freely programmable BACnet room controller, LYNX
Configurable wall modules, no display

Lynx wall module with temperature, no display



CLCMTR40-C02

Centraline Freely programmable BACnet room controller, LYNX
Configurable wall modules, no display

Lynx wall module with temperature + CO2, no display



CLCMTR40-CO2

Centraline Configurable BACnet room controller MERLIN
Configurable wall modules, no display

Lynx wall module with temperature + CO2, no display



CLCMTR40-H

Centraline Freely programmable BACnet room controller, LYNX
Configurable wall modules, no display

Lynx wall module with temperature + humidity, no display



CLCMTR40-H-CO2

Centraline Freely programmable BACnet room controller, LYNX
Configurable wall modules, no display

Lynx wall module with temperature + hum. + CO2, no display



CLCMTR42

Centraline Freely programmable BACnet room controller, LYNX
Configurable wall modules, with display

Lynx wall module with temperature, with display



CLCMTR42-CO2

Centraline Freely programmable BACnet room controller, LYNX
Configurable wall modules, with display

Lynx wall module with temperature + CO2, with display



CLCMTR42-H

Centraline Freely programmable BACnet room controller, LYNX
Configurable wall modules, with display

Lynx wall module with temperature + humidity, with display



CLCMTR42-H-CO2

Centraline Freely programmable BACnet room controller, LYNX
Configurable wall modules, with display

Lynx wall module with temperature + hum. + CO2, with display



CLCMTR71

Centraline Freely programmable BACnet room controller, LYNX
Configurable wall modules, with display

Lynx wall module with room temperature sensor and backlit display



CLCMTR71-H

Centraline Freely programmable BACnet room controller, LYNX
Configurable wall modules, with display

Lynx wall module with room temperature and humidity sensor, and backlit display



CLCMTR75

Centraline Freely programmable BACnet room controller, LYNX
Configurable wall modules, with display

Lynx wall module with room temperature sensor and backlit display, LYNX schedule support



CLCMTR75-H

Centraline Freely programmable BACnet room controller, LYNX
Configurable wall modules, with display

Lynx wall module with room temperature and humidity sensor, and backlit display LYNX schedule support



CLEA2000B21

Centraline Programmable universal BACnet Building Controller, EAGLE

BACnet DDC controller for all HVAC control applications, and building automation functionalities. The controller is BTL and AMEV AS-A certified, and can be applied for stand-alone operation, and in networked systems.
For all buildings.
Control software: free programmable with CentraLine CARE software
programmable with standard software modules
Hardware inputs: Onboard inputs and external input modules available for:
measurement of temperature, relative humidity, pressure etc.
contact status from relays, thermostats etc.
Hardware outputs: Onboard outputs or external output modules available for:
control devices like servomotors
switching devices like pumps, ventilators
Operator panels: Optional onboard or external HMI, with local language operation and plant-specific operation via configurable fast-access-lists
Standard notebook, laptop, touch-panel, PC for full functional operation via Internet Browser. These panels can be used for adjustment of set-points, alarm limits, fixing in/outputs, override functions, trending, plant graphics, etc. Access options are USB port or Ethernet.
Touch-panel (5.7") CLMMI00N31 for full functional operation via Internet Explorer (WIN CE); this touch panel can be used for adjustment of set-points, alarm limits, fixing in/outputs, override functions, etc.
Management applications: ARENA AX
Stand-alone operation: yes
Bus system description: Standard BACnet/IP communication with other BACnet controllers and BACnet Front-Ends
Standard BACnet MS/TP communication with other BACnet MS/TP devices via one or both onboard RS485 interfaces.
Panel bus for communication to Panel I/O modules via one or both onboard RS485 interfaces.
LonWorks(R) bus with the external USB-LON interface adapter IF-LON2, LonWorks(R) transceiver type FTT10A
M-Bus(R) via the onboard RS232 interface plus external M-Bus power supply adaptor (e.g. PW3, PW20, PW60)
Modbus(R) RTU Master via one onboard RS485 interface
HTTP and HTTPS (secure HTTP) communication with webbrowsers.
Mounting: in cabinets
in fuse boxes conforming with standard DIN43880, and having a slot height of max. 45 mm
in cabinet front doors (using accessory MVC-80-AC2)
on walls (using accessory MVC-80-AC1)
Protection class: IP20
Power supply: 19..29 Vac or 20..30 Vdc ; 9 VA
Real-time clock back-up with goldcap capacitor for 72 hours buffer
Use PW3, PW20 or PW60 from Relay, for M-Bus interface

BACnet IP and MS /TP controller
Product description: no onboard IOs, 600 IOs, with built in HMI


CLEA2000B31

Centraline Programmable universal BACnet Building Controller, EAGLE

BACnet DDC controller for all HVAC control applications, and building automation functionalities. The controller is BTL and AMEV AS-A certified, and can be applied for stand-alone operation, and in networked systems.
For all buildings.
Control software: free programmable with CentraLine CARE software
programmable with standard software modules
Hardware inputs: Onboard inputs and external input modules available for:
measurement of temperature, relative humidity, pressure etc.
contact status from relays, thermostats etc.
Hardware outputs: Onboard outputs or external output modules available for:
control devices like servomotors
switching devices like pumps, ventilators
Operator panels: Optional onboard or external HMI, with local language operation and plant-specific operation via configurable fast-access-lists
Standard notebook, laptop, touch-panel, PC for full functional operation via Internet Browser. These panels can be used for adjustment of set-points, alarm limits, fixing in/outputs, override functions, trending, plant graphics, etc. Access options are USB port or Ethernet.
Touch-panel (5.7") CLMMI00N31 for full functional operation via Internet Explorer (WIN CE); this touch panel can be used for adjustment of set-points, alarm limits, fixing in/outputs, override functions, etc.
Management applications: ARENA AX
Stand-alone operation: yes
Bus system description: Standard BACnet/IP communication with other BACnet controllers and BACnet Front-Ends
Standard BACnet MS/TP communication with other BACnet MS/TP devices via one or both onboard RS485 interfaces.
Panel bus for communication to Panel I/O modules via one or both onboard RS485 interfaces.
LonWorks(R) bus with the external USB-LON interface adapter IF-LON2, LonWorks(R) transceiver type FTT10A
M-Bus(R) via the onboard RS232 interface plus external M-Bus power supply adaptor (e.g. PW3, PW20, PW60)
Modbus(R) RTU Master via one onboard RS485 interface
HTTP and HTTPS (secure HTTP) communication with webbrowsers.
Mounting: in cabinets
in fuse boxes conforming with standard DIN43880, and having a slot height of max. 45 mm
in cabinet front doors (using accessory MVC-80-AC2)
on walls (using accessory MVC-80-AC1)
Protection class: IP20
Power supply: 19..29 Vac or 20..30 Vdc ; 9 VA
Real-time clock back-up with goldcap capacitor for 72 hours buffer
Use PW3, PW20 or PW60 from Relay, for M-Bus interface

BACnet IP and MS /TP controller
Product description: no onboard IOs, 600 IOs, with RJ45 socket for external HMI


CLEA2014B21

Centraline Programmable universal BACnet Building Controller, EAGLE

BACnet DDC controller for all HVAC control applications, and building automation functionalities. The controller is BTL and AMEV AS-A certified, and can be applied for stand-alone operation, and in networked systems.
For all buildings.
Control software: free programmable with CentraLine CARE software
programmable with standard software modules
Hardware inputs: Onboard inputs and external input modules available for:
measurement of temperature, relative humidity, pressure etc.
contact status from relays, thermostats etc.
Hardware outputs: Onboard outputs or external output modules available for:
control devices like servomotors
switching devices like pumps, ventilators
Operator panels: Optional onboard or external HMI, with local language operation and plant-specific operation via configurable fast-access-lists
Standard notebook, laptop, touch-panel, PC for full functional operation via Internet Browser. These panels can be used for adjustment of set-points, alarm limits, fixing in/outputs, override functions, trending, plant graphics, etc. Access options are USB port or Ethernet.
Touch-panel (5.7") CLMMI00N31 for full functional operation via Internet Explorer (WIN CE); this touch panel can be used for adjustment of set-points, alarm limits, fixing in/outputs, override functions, etc.
Management applications: ARENA AX
Stand-alone operation: yes
Bus system description: Standard BACnet/IP communication with other BACnet controllers and BACnet Front-Ends
Standard BACnet MS/TP communication with other BACnet MS/TP devices via one or both onboard RS485 interfaces.
Panel bus for communication to Panel I/O modules via one or both onboard RS485 interfaces.
LonWorks(R) bus with the external USB-LON interface adapter IF-LON2, LonWorks(R) transceiver type FTT10A
M-Bus(R) via the onboard RS232 interface plus external M-Bus power supply adaptor (e.g. PW3, PW20, PW60)
Modbus(R) RTU Master via one onboard RS485 interface
HTTP and HTTPS (secure HTTP) communication with webbrowsers.
Mounting: in cabinets
in fuse boxes conforming with standard DIN43880, and having a slot height of max. 45 mm
in cabinet front doors (using accessory MVC-80-AC2)
on walls (using accessory MVC-80-AC1)
Protection class: IP20
Power supply: 19..29 Vac or 20..30 Vdc ; 9 VA
Real-time clock back-up with goldcap capacitor for 72 hours buffer
Use PW3, PW20 or PW60 from Relay, for M-Bus interface

BACnet IP and MS /TP controller
Product description: 14 onboard IOs, 52 IOs, with built in HMI, without Ethernet


CLEA2014B22

Centraline Programmable universal BACnet Building Controller, EAGLE

BACnet DDC controller for all HVAC control applications, and building automation functionalities. The controller is BTL and AMEV AS-A certified, and can be applied for stand-alone operation, and in networked systems.
For all buildings.
Control software: free programmable with CentraLine CARE software
programmable with standard software modules
Hardware inputs: Onboard inputs and external input modules available for:
measurement of temperature, relative humidity, pressure etc.
contact status from relays, thermostats etc.
Hardware outputs: Onboard outputs or external output modules available for:
control devices like servomotors
switching devices like pumps, ventilators
Operator panels: Optional onboard or external HMI, with local language operation and plant-specific operation via configurable fast-access-lists
Standard notebook, laptop, touch-panel, PC for full functional operation via Internet Browser. These panels can be used for adjustment of set-points, alarm limits, fixing in/outputs, override functions, trending, plant graphics, etc. Access options are USB port or Ethernet.
Touch-panel (5.7") CLMMI00N31 for full functional operation via Internet Explorer (WIN CE); this touch panel can be used for adjustment of set-points, alarm limits, fixing in/outputs, override functions, etc.
Management applications: ARENA AX
Stand-alone operation: yes
Bus system description: Standard BACnet/IP communication with other BACnet controllers and BACnet Front-Ends
Standard BACnet MS/TP communication with other BACnet MS/TP devices via one or both onboard RS485 interfaces.
Panel bus for communication to Panel I/O modules via one or both onboard RS485 interfaces.
LonWorks(R) bus with the external USB-LON interface adapter IF-LON2, LonWorks(R) transceiver type FTT10A
M-Bus(R) via the onboard RS232 interface plus external M-Bus power supply adaptor (e.g. PW3, PW20, PW60)
Modbus(R) RTU Master via one onboard RS485 interface
HTTP and HTTPS (secure HTTP) communication with webbrowsers.
Mounting: in cabinets
in fuse boxes conforming with standard DIN43880, and having a slot height of max. 45 mm
in cabinet front doors (using accessory MVC-80-AC2)
on walls (using accessory MVC-80-AC1)
Protection class: IP20
Power supply: 19..29 Vac or 20..30 Vdc ; 9 VA
Real-time clock back-up with goldcap capacitor for 72 hours buffer
Use PW3, PW20 or PW60 from Relay, for M-Bus interface

BACnet IP and MS /TP controller
Product description: 14 onboard IOs, 52 IOs, with built in HMI


CLEA2014B31

Centraline Programmable universal BACnet Building Controller, EAGLE

BACnet DDC controller for all HVAC control applications, and building automation functionalities. The controller is BTL and AMEV AS-A certified, and can be applied for stand-alone operation, and in networked systems.
For all buildings.
Control software: free programmable with CentraLine CARE software
programmable with standard software modules
Hardware inputs: Onboard inputs and external input modules available for:
measurement of temperature, relative humidity, pressure etc.
contact status from relays, thermostats etc.
Hardware outputs: Onboard outputs or external output modules available for:
control devices like servomotors
switching devices like pumps, ventilators
Operator panels: Optional onboard or external HMI, with local language operation and plant-specific operation via configurable fast-access-lists
Standard notebook, laptop, touch-panel, PC for full functional operation via Internet Browser. These panels can be used for adjustment of set-points, alarm limits, fixing in/outputs, override functions, trending, plant graphics, etc. Access options are USB port or Ethernet.
Touch-panel (5.7") CLMMI00N31 for full functional operation via Internet Explorer (WIN CE); this touch panel can be used for adjustment of set-points, alarm limits, fixing in/outputs, override functions, etc.
Management applications: ARENA AX
Stand-alone operation: yes
Bus system description: Standard BACnet/IP communication with other BACnet controllers and BACnet Front-Ends
Standard BACnet MS/TP communication with other BACnet MS/TP devices via one or both onboard RS485 interfaces.
Panel bus for communication to Panel I/O modules via one or both onboard RS485 interfaces.
LonWorks(R) bus with the external USB-LON interface adapter IF-LON2, LonWorks(R) transceiver type FTT10A
M-Bus(R) via the onboard RS232 interface plus external M-Bus power supply adaptor (e.g. PW3, PW20, PW60)
Modbus(R) RTU Master via one onboard RS485 interface
HTTP and HTTPS (secure HTTP) communication with webbrowsers.
Mounting: in cabinets
in fuse boxes conforming with standard DIN43880, and having a slot height of max. 45 mm
in cabinet front doors (using accessory MVC-80-AC2)
on walls (using accessory MVC-80-AC1)
Protection class: IP20
Power supply: 19..29 Vac or 20..30 Vdc ; 9 VA
Real-time clock back-up with goldcap capacitor for 72 hours buffer
Use PW3, PW20 or PW60 from Relay, for M-Bus interface

BACnet IP and MS /TP controller
Product description: 14 onboard IOs, 52 IOs, with RJ45 socket for external HMI, without Ethernet


CLEA2014B32

Centraline Programmable universal BACnet Building Controller, EAGLE

BACnet DDC controller for all HVAC control applications, and building automation functionalities. The controller is BTL and AMEV AS-A certified, and can be applied for stand-alone operation, and in networked systems.
For all buildings.
Control software: free programmable with CentraLine CARE software
programmable with standard software modules
Hardware inputs: Onboard inputs and external input modules available for:
measurement of temperature, relative humidity, pressure etc.
contact status from relays, thermostats etc.
Hardware outputs: Onboard outputs or external output modules available for:
control devices like servomotors
switching devices like pumps, ventilators
Operator panels: Optional onboard or external HMI, with local language operation and plant-specific operation via configurable fast-access-lists
Standard notebook, laptop, touch-panel, PC for full functional operation via Internet Browser. These panels can be used for adjustment of set-points, alarm limits, fixing in/outputs, override functions, trending, plant graphics, etc. Access options are USB port or Ethernet.
Touch-panel (5.7") CLMMI00N31 for full functional operation via Internet Explorer (WIN CE); this touch panel can be used for adjustment of set-points, alarm limits, fixing in/outputs, override functions, etc.
Management applications: ARENA AX
Stand-alone operation: yes
Bus system description: Standard BACnet/IP communication with other BACnet controllers and BACnet Front-Ends
Standard BACnet MS/TP communication with other BACnet MS/TP devices via one or both onboard RS485 interfaces.
Panel bus for communication to Panel I/O modules via one or both onboard RS485 interfaces.
LonWorks(R) bus with the external USB-LON interface adapter IF-LON2, LonWorks(R) transceiver type FTT10A
M-Bus(R) via the onboard RS232 interface plus external M-Bus power supply adaptor (e.g. PW3, PW20, PW60)
Modbus(R) RTU Master via one onboard RS485 interface
HTTP and HTTPS (secure HTTP) communication with webbrowsers.
Mounting: in cabinets
in fuse boxes conforming with standard DIN43880, and having a slot height of max. 45 mm
in cabinet front doors (using accessory MVC-80-AC2)
on walls (using accessory MVC-80-AC1)
Protection class: IP20
Power supply: 19..29 Vac or 20..30 Vdc ; 9 VA
Real-time clock back-up with goldcap capacitor for 72 hours buffer
Use PW3, PW20 or PW60 from Relay, for M-Bus interface

BACnet IP and MS /TP controller
Product description: 14 onboard IOs, 52 IOs, with RJ45 socket for external HMI


CLEA2026B21

Centraline Programmable universal BACnet Building Controller, EAGLE

BACnet DDC controller for all HVAC control applications, and building automation functionalities. The controller is BTL and AMEV AS-A certified, and can be applied for stand-alone operation, and in networked systems.
For all buildings.
Control software: free programmable with CentraLine CARE software
programmable with standard software modules
Hardware inputs: Onboard inputs and external input modules available for:
measurement of temperature, relative humidity, pressure etc.
contact status from relays, thermostats etc.
Hardware outputs: Onboard outputs or external output modules available for:
control devices like servomotors
switching devices like pumps, ventilators
Operator panels: Optional onboard or external HMI, with local language operation and plant-specific operation via configurable fast-access-lists
Standard notebook, laptop, touch-panel, PC for full functional operation via Internet Browser. These panels can be used for adjustment of set-points, alarm limits, fixing in/outputs, override functions, trending, plant graphics, etc. Access options are USB port or Ethernet.
Touch-panel (5.7") CLMMI00N31 for full functional operation via Internet Explorer (WIN CE); this touch panel can be used for adjustment of set-points, alarm limits, fixing in/outputs, override functions, etc.
Management applications: ARENA AX
Stand-alone operation: yes
Bus system description: Standard BACnet/IP communication with other BACnet controllers and BACnet Front-Ends
Standard BACnet MS/TP communication with other BACnet MS/TP devices via one or both onboard RS485 interfaces.
Panel bus for communication to Panel I/O modules via one or both onboard RS485 interfaces.
LonWorks(R) bus with the external USB-LON interface adapter IF-LON2, LonWorks(R) transceiver type FTT10A
M-Bus(R) via the onboard RS232 interface plus external M-Bus power supply adaptor (e.g. PW3, PW20, PW60)
Modbus(R) RTU Master via one onboard RS485 interface
HTTP and HTTPS (secure HTTP) communication with webbrowsers.
Mounting: in cabinets
in fuse boxes conforming with standard DIN43880, and having a slot height of max. 45 mm
in cabinet front doors (using accessory MVC-80-AC2)
on walls (using accessory MVC-80-AC1)
Protection class: IP20
Power supply: 19..29 Vac or 20..30 Vdc ; 9 VA
Real-time clock back-up with goldcap capacitor for 72 hours buffer
Use PW3, PW20 or PW60 from Relay, for M-Bus interface

BACnet IP and MS /TP controller
Product description: 26 onboard IOs, 600 IOs, with built in HMI


CLEA2026B31

Centraline Programmable universal BACnet Building Controller, EAGLE

BACnet DDC controller for all HVAC control applications, and building automation functionalities. The controller is BTL and AMEV AS-A certified, and can be applied for stand-alone operation, and in networked systems.
For all buildings.
Control software: free programmable with CentraLine CARE software
programmable with standard software modules
Hardware inputs: Onboard inputs and external input modules available for:
measurement of temperature, relative humidity, pressure etc.
contact status from relays, thermostats etc.
Hardware outputs: Onboard outputs or external output modules available for:
control devices like servomotors
switching devices like pumps, ventilators
Operator panels: Optional onboard or external HMI, with local language operation and plant-specific operation via configurable fast-access-lists
Standard notebook, laptop, touch-panel, PC for full functional operation via Internet Browser. These panels can be used for adjustment of set-points, alarm limits, fixing in/outputs, override functions, trending, plant graphics, etc. Access options are USB port or Ethernet.
Touch-panel (5.7") CLMMI00N31 for full functional operation via Internet Explorer (WIN CE); this touch panel can be used for adjustment of set-points, alarm limits, fixing in/outputs, override functions, etc.
Management applications: ARENA AX
Stand-alone operation: yes
Bus system description: Standard BACnet/IP communication with other BACnet controllers and BACnet Front-Ends
Standard BACnet MS/TP communication with other BACnet MS/TP devices via one or both onboard RS485 interfaces.
Panel bus for communication to Panel I/O modules via one or both onboard RS485 interfaces.
LonWorks(R) bus with the external USB-LON interface adapter IF-LON2, LonWorks(R) transceiver type FTT10A
M-Bus(R) via the onboard RS232 interface plus external M-Bus power supply adaptor (e.g. PW3, PW20, PW60)
Modbus(R) RTU Master via one onboard RS485 interface
HTTP and HTTPS (secure HTTP) communication with webbrowsers.
Mounting: in cabinets
in fuse boxes conforming with standard DIN43880, and having a slot height of max. 45 mm
in cabinet front doors (using accessory MVC-80-AC2)
on walls (using accessory MVC-80-AC1)
Protection class: IP20
Power supply: 19..29 Vac or 20..30 Vdc ; 9 VA
Real-time clock back-up with goldcap capacitor for 72 hours buffer
Use PW3, PW20 or PW60 from Relay, for M-Bus interface

BACnet IP and MS /TP controller
Product description: 26 onboard IOs, 600 IOs, with RJ45 socket for external HMI


CLEAHMI-BASE

Centraline Programmable universal BACnet Building Controller, EAGLE

BACnet DDC controller for all HVAC control applications, and building automation functionalities. The controller is BTL and AMEV AS-A certified, and can be applied for stand-alone operation, and in networked systems.
For all buildings.
Control software: free programmable with CentraLine CARE software
programmable with standard software modules
Hardware inputs: Onboard inputs and external input modules available for:
measurement of temperature, relative humidity, pressure etc.
contact status from relays, thermostats etc.
Hardware outputs: Onboard outputs or external output modules available for:
control devices like servomotors
switching devices like pumps, ventilators
Operator panels: Optional onboard or external HMI, with local language operation and plant-specific operation via configurable fast-access-lists
Standard notebook, laptop, touch-panel, PC for full functional operation via Internet Browser. These panels can be used for adjustment of set-points, alarm limits, fixing in/outputs, override functions, trending, plant graphics, etc. Access options are USB port or Ethernet.
Touch-panel (5.7") CLMMI00N31 for full functional operation via Internet Explorer (WIN CE); this touch panel can be used for adjustment of set-points, alarm limits, fixing in/outputs, override functions, etc.
Management applications: ARENA AX
Stand-alone operation: yes
Bus system description: Standard BACnet/IP communication with other BACnet controllers and BACnet Front-Ends
Standard BACnet MS/TP communication with other BACnet MS/TP devices via one or both onboard RS485 interfaces.
Panel bus for communication to Panel I/O modules via one or both onboard RS485 interfaces.
LonWorks(R) bus with the external USB-LON interface adapter IF-LON2, LonWorks(R) transceiver type FTT10A
M-Bus(R) via the onboard RS232 interface plus external M-Bus power supply adaptor (e.g. PW3, PW20, PW60)
Modbus(R) RTU Master via one onboard RS485 interface
HTTP and HTTPS (secure HTTP) communication with webbrowsers.
Mounting: in cabinets
in fuse boxes conforming with standard DIN43880, and having a slot height of max. 45 mm
in cabinet front doors (using accessory MVC-80-AC2)
on walls (using accessory MVC-80-AC1)
Protection class: IP20
Power supply: 19..29 Vac or 20..30 Vdc ; 9 VA
Real-time clock back-up with goldcap capacitor for 72 hours buffer
Use PW3, PW20 or PW60 from Relay, for M-Bus interface

External HMI. Mounting in cabinet front door, or with CLEAHMI-BASE: on wall/metal surface or used as handheld. Connection with Ethernet cable, max. 5m
Product description: Wall-mounting subbase for external HMI; including magnets for magnet mounting and including back cover for handheld


CLEAHMI21

Centraline Programmable universal BACnet Building Controller, EAGLE

BACnet DDC controller for all HVAC control applications, and building automation functionalities. The controller is BTL and AMEV AS-A certified, and can be applied for stand-alone operation, and in networked systems.
For all buildings.
Control software: free programmable with CentraLine CARE software
programmable with standard software modules
Hardware inputs: Onboard inputs and external input modules available for:
measurement of temperature, relative humidity, pressure etc.
contact status from relays, thermostats etc.
Hardware outputs: Onboard outputs or external output modules available for:
control devices like servomotors
switching devices like pumps, ventilators
Operator panels: Optional onboard or external HMI, with local language operation and plant-specific operation via configurable fast-access-lists
Standard notebook, laptop, touch-panel, PC for full functional operation via Internet Browser. These panels can be used for adjustment of set-points, alarm limits, fixing in/outputs, override functions, trending, plant graphics, etc. Access options are USB port or Ethernet.
Touch-panel (5.7") CLMMI00N31 for full functional operation via Internet Explorer (WIN CE); this touch panel can be used for adjustment of set-points, alarm limits, fixing in/outputs, override functions, etc.
Management applications: ARENA AX
Stand-alone operation: yes
Bus system description: Standard BACnet/IP communication with other BACnet controllers and BACnet Front-Ends
Standard BACnet MS/TP communication with other BACnet MS/TP devices via one or both onboard RS485 interfaces.
Panel bus for communication to Panel I/O modules via one or both onboard RS485 interfaces.
LonWorks(R) bus with the external USB-LON interface adapter IF-LON2, LonWorks(R) transceiver type FTT10A
M-Bus(R) via the onboard RS232 interface plus external M-Bus power supply adaptor (e.g. PW3, PW20, PW60)
Modbus(R) RTU Master via one onboard RS485 interface
HTTP and HTTPS (secure HTTP) communication with webbrowsers.
Mounting: in cabinets
in fuse boxes conforming with standard DIN43880, and having a slot height of max. 45 mm
in cabinet front doors (using accessory MVC-80-AC2)
on walls (using accessory MVC-80-AC1)
Protection class: IP20
Power supply: 19..29 Vac or 20..30 Vdc ; 9 VA
Real-time clock back-up with goldcap capacitor for 72 hours buffer
Use PW3, PW20 or PW60 from Relay, for M-Bus interface

External HMI. Mounting in cabinet front door, or with CLEAHMI-BASE: on wall/metal surface or used as handheld. Connection with Ethernet cable, max. 5m
Product description: Optional external HMI, with local language operation and plant-specific operation via configurable fast-access-lists


CLEMADVCHARTS

Centraline ENERGY VISION

ENERGY VISION is a professional tool for energy benchmarking and analysis, built on Niagara web graphics technology, providing a large range of techniques for managing all aspects of energy related data. EnergyVision is the ideal system to:
help manage energy, analyse and optimise the operation of facilities
measure performance across multiple levels within your building or estate
It is fully web-enabled and able to integrate data from a wide range of existing systems. HAWK and ARENA AX can provide data from most of the metering devices used in the market. It enables an integrated solution, allowing the user to collate and manage all aspects of their energy data at a central location.
FEATURES and BENEFITS
Completely integrated into Niagara AX: Save costs. NO additional equipment needed. Get metering data from most of the metering communication protocols in the market.
Automatically collect and aggregate metering data: No need for expensive data collection devices. Reliable and continuous data collection. No need to send the housekeeper to note metering data.
Monitor energy consumption with daily, weekly, monthly or annual profiles: Easily recognize waste of energy.
Analyse energy profiles: Detect waste of energy. Optimize energy efficiency.
Translate raw energy values into monetary units: Always have an overview of the energy costs. Compare actual costs with budget.
Energy Benchmarking graphs, with weekly, monthly, yearly views: Prove the efficiency of your energy saving actions. Easily understand how your energy consumption is against target profiles or historical consumptions.
Visualization and ranking of consumption between meters, zones, systems, buildings, sites: Get an overview of your highest consumers. Start optimizing your energy efficiency, where you can achieve the biggest savings.
Instant and automatic reports for users, energy managers and auditors: Save costs for generating energy reports. Have the relevant data for energy managers and auditors with highest accuracy and just in time.
Kiosk Mode - a rotating sequence of easy understandable energy efficiency data: Use in a building foyer or reception area to raise occupants awareness.
Honeywell offers the complete meter portfolio: Honeywell offers all the needed metering devices starting from one and three phase electrical meters, heating, cooling energy meters, hot and cold water meters and all kinds of flow meters.
Cost-efficient solution: Logos/layout can be customized free of charge. All components are part of an AX palette low effort for technical support. Existing BACnet Schedules can be used.
Low training effort for engineers and users: Low training efforts for customers and partners/ engineers. Training video are available on the partner web. Very easy installation and start-up.

ENERGY VISION supporting:
Product description: Advanced Charts and Reports


CLEMC12

Centraline ENERGY VISION

ENERGY VISION is a professional tool for energy benchmarking and analysis, built on Niagara web graphics technology, providing a large range of techniques for managing all aspects of energy related data. EnergyVision is the ideal system to:
help manage energy, analyse and optimise the operation of facilities
measure performance across multiple levels within your building or estate
It is fully web-enabled and able to integrate data from a wide range of existing systems. HAWK and ARENA AX can provide data from most of the metering devices used in the market. It enables an integrated solution, allowing the user to collate and manage all aspects of their energy data at a central location.
FEATURES and BENEFITS
Completely integrated into Niagara AX: Save costs. NO additional equipment needed. Get metering data from most of the metering communication protocols in the market.
Automatically collect and aggregate metering data: No need for expensive data collection devices. Reliable and continuous data collection. No need to send the housekeeper to note metering data.
Monitor energy consumption with daily, weekly, monthly or annual profiles: Easily recognize waste of energy.
Analyse energy profiles: Detect waste of energy. Optimize energy efficiency.
Translate raw energy values into monetary units: Always have an overview of the energy costs. Compare actual costs with budget.
Energy Benchmarking graphs, with weekly, monthly, yearly views: Prove the efficiency of your energy saving actions. Easily understand how your energy consumption is against target profiles or historical consumptions.
Visualization and ranking of consumption between meters, zones, systems, buildings, sites: Get an overview of your highest consumers. Start optimizing your energy efficiency, where you can achieve the biggest savings.
Instant and automatic reports for users, energy managers and auditors: Save costs for generating energy reports. Have the relevant data for energy managers and auditors with highest accuracy and just in time.
Kiosk Mode - a rotating sequence of easy understandable energy efficiency data: Use in a building foyer or reception area to raise occupants awareness.
Honeywell offers the complete meter portfolio: Honeywell offers all the needed metering devices starting from one and three phase electrical meters, heating, cooling energy meters, hot and cold water meters and all kinds of flow meters.
Cost-efficient solution: Logos/layout can be customized free of charge. All components are part of an AX palette low effort for technical support. Existing BACnet Schedules can be used.
Low training effort for engineers and users: Low training efforts for customers and partners/ engineers. Training video are available on the partner web. Very easy installation and start-up.

ENERGY VISION supporting:
Product description: License for Hawk or ARENA AX with maximum 12 meters


CLEMS75

Centraline ENERGY VISION

ENERGY VISION is a professional tool for energy benchmarking and analysis, built on Niagara web graphics technology, providing a large range of techniques for managing all aspects of energy related data. EnergyVision is the ideal system to:
help manage energy, analyse and optimise the operation of facilities
measure performance across multiple levels within your building or estate
It is fully web-enabled and able to integrate data from a wide range of existing systems. HAWK and ARENA AX can provide data from most of the metering devices used in the market. It enables an integrated solution, allowing the user to collate and manage all aspects of their energy data at a central location.
FEATURES and BENEFITS
Completely integrated into Niagara AX: Save costs. NO additional equipment needed. Get metering data from most of the metering communication protocols in the market.
Automatically collect and aggregate metering data: No need for expensive data collection devices. Reliable and continuous data collection. No need to send the housekeeper to note metering data.
Monitor energy consumption with daily, weekly, monthly or annual profiles: Easily recognize waste of energy.
Analyse energy profiles: Detect waste of energy. Optimize energy efficiency.
Translate raw energy values into monetary units: Always have an overview of the energy costs. Compare actual costs with budget.
Energy Benchmarking graphs, with weekly, monthly, yearly views: Prove the efficiency of your energy saving actions. Easily understand how your energy consumption is against target profiles or historical consumptions.
Visualization and ranking of consumption between meters, zones, systems, buildings, sites: Get an overview of your highest consumers. Start optimizing your energy efficiency, where you can achieve the biggest savings.
Instant and automatic reports for users, energy managers and auditors: Save costs for generating energy reports. Have the relevant data for energy managers and auditors with highest accuracy and just in time.
Kiosk Mode - a rotating sequence of easy understandable energy efficiency data: Use in a building foyer or reception area to raise occupants awareness.
Honeywell offers the complete meter portfolio: Honeywell offers all the needed metering devices starting from one and three phase electrical meters, heating, cooling energy meters, hot and cold water meters and all kinds of flow meters.
Cost-efficient solution: Logos/layout can be customized free of charge. All components are part of an AX palette low effort for technical support. Existing BACnet Schedules can be used.
Low training effort for engineers and users: Low training efforts for customers and partners/ engineers. Training video are available on the partner web. Very easy installation and start-up.

ENERGY VISION supporting:
Product description: Basic supervisor license (for ARENA AX) with maximum 75 meters


CLEMSPRO

Centraline ENERGY VISION

ENERGY VISION is a professional tool for energy benchmarking and analysis, built on Niagara web graphics technology, providing a large range of techniques for managing all aspects of energy related data. EnergyVision is the ideal system to:
help manage energy, analyse and optimise the operation of facilities
measure performance across multiple levels within your building or estate
It is fully web-enabled and able to integrate data from a wide range of existing systems. HAWK and ARENA AX can provide data from most of the metering devices used in the market. It enables an integrated solution, allowing the user to collate and manage all aspects of their energy data at a central location.
FEATURES and BENEFITS
Completely integrated into Niagara AX: Save costs. NO additional equipment needed. Get metering data from most of the metering communication protocols in the market.
Automatically collect and aggregate metering data: No need for expensive data collection devices. Reliable and continuous data collection. No need to send the housekeeper to note metering data.
Monitor energy consumption with daily, weekly, monthly or annual profiles: Easily recognize waste of energy.
Analyse energy profiles: Detect waste of energy. Optimize energy efficiency.
Translate raw energy values into monetary units: Always have an overview of the energy costs. Compare actual costs with budget.
Energy Benchmarking graphs, with weekly, monthly, yearly views: Prove the efficiency of your energy saving actions. Easily understand how your energy consumption is against target profiles or historical consumptions.
Visualization and ranking of consumption between meters, zones, systems, buildings, sites: Get an overview of your highest consumers. Start optimizing your energy efficiency, where you can achieve the biggest savings.
Instant and automatic reports for users, energy managers and auditors: Save costs for generating energy reports. Have the relevant data for energy managers and auditors with highest accuracy and just in time.
Kiosk Mode - a rotating sequence of easy understandable energy efficiency data: Use in a building foyer or reception area to raise occupants awareness.
Honeywell offers the complete meter portfolio: Honeywell offers all the needed metering devices starting from one and three phase electrical meters, heating, cooling energy meters, hot and cold water meters and all kinds of flow meters.
Cost-efficient solution: Logos/layout can be customized free of charge. All components are part of an AX palette low effort for technical support. Existing BACnet Schedules can be used.
Low training effort for engineers and users: Low training efforts for customers and partners/ engineers. Training video are available on the partner web. Very easy installation and start-up.

ENERGY VISION supporting:
Product description: Professional supervisor license for ARENA AX for maximum 1400 meters and 5 sites


CLEUPGR75PRO

Centraline ENERGY VISION

ENERGY VISION is a professional tool for energy benchmarking and analysis, built on Niagara web graphics technology, providing a large range of techniques for managing all aspects of energy related data. EnergyVision is the ideal system to:
help manage energy, analyse and optimise the operation of facilities
measure performance across multiple levels within your building or estate
It is fully web-enabled and able to integrate data from a wide range of existing systems. HAWK and ARENA AX can provide data from most of the metering devices used in the market. It enables an integrated solution, allowing the user to collate and manage all aspects of their energy data at a central location.
FEATURES and BENEFITS
Completely integrated into Niagara AX: Save costs. NO additional equipment needed. Get metering data from most of the metering communication protocols in the market.
Automatically collect and aggregate metering data: No need for expensive data collection devices. Reliable and continuous data collection. No need to send the housekeeper to note metering data.
Monitor energy consumption with daily, weekly, monthly or annual profiles: Easily recognize waste of energy.
Analyse energy profiles: Detect waste of energy. Optimize energy efficiency.
Translate raw energy values into monetary units: Always have an overview of the energy costs. Compare actual costs with budget.
Energy Benchmarking graphs, with weekly, monthly, yearly views: Prove the efficiency of your energy saving actions. Easily understand how your energy consumption is against target profiles or historical consumptions.
Visualization and ranking of consumption between meters, zones, systems, buildings, sites: Get an overview of your highest consumers. Start optimizing your energy efficiency, where you can achieve the biggest savings.
Instant and automatic reports for users, energy managers and auditors: Save costs for generating energy reports. Have the relevant data for energy managers and auditors with highest accuracy and just in time.
Kiosk Mode - a rotating sequence of easy understandable energy efficiency data: Use in a building foyer or reception area to raise occupants awareness.
Honeywell offers the complete meter portfolio: Honeywell offers all the needed metering devices starting from one and three phase electrical meters, heating, cooling energy meters, hot and cold water meters and all kinds of flow meters.
Cost-efficient solution: Logos/layout can be customized free of charge. All components are part of an AX palette low effort for technical support. Existing BACnet Schedules can be used.
Low training effort for engineers and users: Low training efforts for customers and partners/ engineers. Training video are available on the partner web. Very easy installation and start-up.

ENERGY VISION supporting:
Product description: Upgrade from Supervisor Basic to Supervisor professional


CLIF-CBUSLC

Centraline C-Bus interfaces

C-Bus Interfaces


Product description: C-Bus to TCP/ IP adapter for one physical C-Bus and one C-Bus via LON. The device needs the LON-USB interface IF-LON2


CLIOL821A

Centraline LON I/O modules

LON I/O modules for CentraLine controllers.
cabinet, DIN-rail, fuse box, or wall mounting
override switches and potentiometer operation
LED functions configurable
safety positions configurable
fixed terminals
power supply 24 Vac
short-circuit protected

LON I/O modules
Product description: 8 analog input module NTC10k, NTC20k, Ni1000TK5000, Pt1000, Pt3000, Balco500, contact


CLIOL821A-BLK20

Centraline EAGLEHAWK Integrated Plant Control
Bulk packages

20x CLIOL821A and 20x XS821-22



CLIOL822A

Centraline LON I/O modules

LON I/O modules for CentraLine controllers.
cabinet, DIN-rail, fuse box, or wall mounting
override switches and potentiometer operation
LED functions configurable
safety positions configurable
fixed terminals
power supply 24 Vac
short-circuit protected

LON I/O modules
Product description: 8 analog output module 0..10Vdc, 3-pt, binary 0/10V


CLIOL822A-BLK10

Centraline EAGLEHAWK Integrated Plant Control
Bulk packages

10x CLIOL822A and 10x XS821-22



CLIOL823A

Centraline LON I/O modules

LON I/O modules for CentraLine controllers.
cabinet, DIN-rail, fuse box, or wall mounting
override switches and potentiometer operation
LED functions configurable
safety positions configurable
fixed terminals
power supply 24 Vac
short-circuit protected

LON I/O modules
Product description: 12 binary input module for contact or totalizer contact 20 Hz


CLIOL823A-BLK20

Centraline EAGLEHAWK Integrated Plant Control
Bulk packages

20x CLIOL823A and 20x XS823



CLIOL824A

Centraline LON I/O modules

LON I/O modules for CentraLine controllers.
cabinet, DIN-rail, fuse box, or wall mounting
override switches and potentiometer operation
LED functions configurable
safety positions configurable
fixed terminals
power supply 24 Vac
short-circuit protected

LON I/O modules
Product description: 6 relay output module SPDT 250V, 2(1) A, feedback


CLIOL824A-BLK10

Centraline EAGLEHAWK Integrated Plant Control
Bulk packages

10x CLIOL824A and 10x XS824-25



CLIOLR822A

Centraline LON I/O modules

LON I/O modules for CentraLine controllers.
cabinet, DIN-rail, fuse box, or wall mounting
override switches and potentiometer operation
LED functions configurable
safety positions configurable
fixed terminals
power supply 24 Vac
short-circuit protected

LON I/O modules
Product description: 8 analog output module 0..10Vdc, 3-pt, binary 0/10V; with override potentiometer


CLIOLR822A-BLK10

Centraline EAGLEHAWK Integrated Plant Control
Bulk packages

10x CLIOLR822A and 10x XS821-22



CLIOLR824A

Centraline LON I/O modules

LON I/O modules for CentraLine controllers.
cabinet, DIN-rail, fuse box, or wall mounting
override switches and potentiometer operation
LED functions configurable
safety positions configurable
fixed terminals
power supply 24 Vac
short-circuit protected

LON I/O modules
Product description: 6 relay output module SPDT 250V, 2(1) A, feedback; with override switch


CLIOLR824A-BLK10

Centraline EAGLEHAWK Integrated Plant Control
Bulk packages

10x CLIOLR824A and 10x XS824-25



CLIOP821A

Centraline Panel-Bus IOs

PANEL I/O modules, -configurable LED functions, -safety positions, -short circuit protection

PANEL I/O modules, -configurable LED functions, - safety positions, - short circuit protection
Product description: 8 analog input module NTC10k, NTC20k, Ni1000TK5000, Pt1000, Pt3000, Balco500, contact


CLIOP821A-BLK20

Centraline Panel-Bus IOs

PANEL I/O modules, -configurable LED functions, -safety positions, -short circuit protection

Bulk packages
Product description: 20x CLIOP821A and 20x XS821-22


CLIOP822A

Centraline Panel-Bus IOs

PANEL I/O modules, -configurable LED functions, -safety positions, -short circuit protection

PANEL I/O modules, -configurable LED functions, - safety positions, - short circuit protection
Product description: 8 analog output module 0..10Vdc, 3-pt, binary 0/10V


CLIOP823A

Centraline Panel-Bus IOs

PANEL I/O modules, -configurable LED functions, -safety positions, -short circuit protection

PANEL I/O modules, -configurable LED functions, - safety positions, - short circuit protection
Product description: 12 binary input module for contact or totalizer contact 20 Hz


CLIOP823A-BLK20

Centraline Panel-Bus IOs

PANEL I/O modules, -configurable LED functions, -safety positions, -short circuit protection

Bulk packages
Product description: 20x CLIOP823A and 20x XS823


CLIOP824A

Centraline Panel-Bus IOs

PANEL I/O modules, -configurable LED functions, -safety positions, -short circuit protection

PANEL I/O modules, -configurable LED functions, - safety positions, - short circuit protection
Product description: 6 relay output module SPDT 250V, 2(1) A, feedback


CLIOP830A

Centraline Panel-Bus IOs

PANEL I/O modules, -configurable LED functions, -safety positions, -short circuit protection

Panel Mixed I/O modules, 8 AI NTC20k, 8 AO 0..10Vdc, 12 binary 15Hz, 6 relays 24V 0,5A
Product description: Mixed I/O module with push-in terminals


CLIOP830A-BLK10

Centraline Panel-Bus IOs

PANEL I/O modules, -configurable LED functions, -safety positions, -short circuit protection

Bulk packages
Product description: 10x CLIOP830A


CLIOP831A

Centraline Panel-Bus IOs

PANEL I/O modules, -configurable LED functions, -safety positions, -short circuit protection

Panel Mixed I/O modules, 8 AI NTC20k, 8 AO 0..10Vdc, 12 binary 15Hz, 6 relays 24V 0,5A
Product description: Mixed I/O module with screw terminals


CLIOP831A-BLK10

Centraline Panel-Bus IOs

PANEL I/O modules, -configurable LED functions, -safety positions, -short circuit protection

Bulk packages
Product description: 10x CLIOP831A


CLIOPR822A

Centraline Panel-Bus IOs

PANEL I/O modules, -configurable LED functions, -safety positions, -short circuit protection

PANEL I/O modules, -configurable LED functions, - safety positions, - short circuit protection
Product description: 8 analog output module 0..10Vdc, 3-pt, binary 0/10V; with override potentiometer


CLIOPR822A-BLK10

Centraline Panel-Bus IOs

PANEL I/O modules, -configurable LED functions, -safety positions, -short circuit protection

Bulk packages
Product description: 10x CLIOPR822A and 10x XS821-22


CLIOPR824A

Centraline Panel-Bus IOs

PANEL I/O modules, -configurable LED functions, -safety positions, -short circuit protection

PANEL I/O modules, -configurable LED functions, - safety positions, - short circuit protection
Product description: 6 relay output module SPDT 250V, 2(1) A, feedback; with override switch


CLIOPR824A-BLK10

Centraline EAGLEHAWK Integrated Plant Control
Bulk packages

10x CLIOLR824A and 10x XS824-25



CLIOPR825A

Centraline Panel-Bus IOs

PANEL I/O modules, -configurable LED functions, -safety positions, -short circuit protection

PANEL I/O modules, -configurable LED functions, - safety positions, - short circuit protection
Product description: 3-point control output module, with override switch; for 1 actuator


CLLIONLC01

Centraline Programmable universal HVAC controller, CentraLine LION

DDC controller for all HVAC control applications, and building automation functionalities. The controller can be applied for stand-alone operation, dial-up and in network systems.
For all buildings.
Control software: configurable with COACH software
free programmable with CARE software
programmable with standard ModAL software modules
Hardware inputs: Panel Bus and LON Bus input modules available for:
measurement of temperature, relative humidity, pressure etc.
contact status from relays, thermostats etc.
Hardware outputs: Panel Bus and LON Bus output modules available for:
control devices like servomotors (configuration of safety position is possible)
switching devices like pumps, ventilators
Operator panels: RS232 port available for operator panels CLMMI00N22/CLMMI00N31; these panels can be used for adjustment of setpoints, alarm limits, fixing in/outputs, override functions, graphic trending etc.
Stand-alone operation: yes
Bus system description: communication bus ("physical C-bus" or "C-bus over LON")
LonWorks(R) bus
Panel bus for communication to Panel I/O modules
Transceiver type: LonWorks(R) FTT10A
Mounting: DIN rail
Protection class: IP30
Memory back-up: goldcap capacitor for 72 hours buffer
Power supply: 24Vacdc
Modem connection: directly connectable
C-bus connection: directly connectable
LonWorks(R) connection: directly connectable
Panel bus connection: directly connectable

LION Plant Controller
Product description: Controller


CLLYUB1012S

Centraline Freely programmable BACnet room controller, LYNX

The controllers are for use in VAV (Variable Air Volume) and Unitary HVAC control applications. Each controller communicates via LonWorks(R) or BACnet MS/TP network communications. Each controller provides flexible, universal inputs for external sensors, digital inputs, and a combination of analog outputs and digital Triac outputs. The Sylk Bus is included in each controller which enables connection to other Sylk enabled devices. These controllers provide many options and advanced system features that allow state-of-the-art individual room control. Each controller is freely programmable and configurable. Direct BACnet (MSTP) connection.

Unitary Controllers without pressure sensor and without actuator
Hardware inputs: 1 universal
Hardware outputs: 1 analog, 2 digital
Power supply: 24Vac


CLLYUB4024S

Centraline Freely programmable BACnet room controller, LYNX

The controllers are for use in VAV (Variable Air Volume) and Unitary HVAC control applications. Each controller communicates via LonWorks(R) or BACnet MS/TP network communications. Each controller provides flexible, universal inputs for external sensors, digital inputs, and a combination of analog outputs and digital Triac outputs. The Sylk Bus is included in each controller which enables connection to other Sylk enabled devices. These controllers provide many options and advanced system features that allow state-of-the-art individual room control. Each controller is freely programmable and configurable. Direct BACnet (MSTP) connection.

Unitary Controllers without pressure sensor and without actuator
Hardware inputs: 4 universal
Hardware outputs: 2 analog, 4 digital
Power supply: 24Vac


CLLYUB6438S

Centraline Freely programmable BACnet room controller, LYNX

The controllers are for use in VAV (Variable Air Volume) and Unitary HVAC control applications. Each controller communicates via LonWorks(R) or BACnet MS/TP network communications. Each controller provides flexible, universal inputs for external sensors, digital inputs, and a combination of analog outputs and digital Triac outputs. The Sylk Bus is included in each controller which enables connection to other Sylk enabled devices. These controllers provide many options and advanced system features that allow state-of-the-art individual room control. Each controller is freely programmable and configurable. Direct BACnet (MSTP) connection.

Unitary Controllers without pressure sensor and without actuator
Hardware inputs: 6 universal, 4 digital
Hardware outputs: 3 analog, 8 digital
Power supply: 24Vac


CLLYUL1012S

Centraline Freely programmable LonWorks room controller, LYNX

The controllers are for use in VAV (Variable Air Volume) and Unitary HVAC control applications. Each controller communicates via LonWorks or BACnet MS/TP network communications. Each controller provides flexible, universal inputs for external sensors, digital inputs, and a combination of analog outputs and digital Triac outputs. The Sylk Bus is included in each controller which enables connection to other Sylk enabled devices. These controllers provide many options and advanced system features that allow state-of-the-art individual room control. Each controller is freely programmable and configurable. Direct LonWorks connection.
LonWorks(R) connection: directly connectable

Unitary Controllers without pressure sensor and without actuator
Hardware inputs: 1 universal
Hardware outputs: 1 analog, 2 digital
Power supply: 24Vac


CLLYUL4024S

Centraline Freely programmable LonWorks room controller, LYNX

The controllers are for use in VAV (Variable Air Volume) and Unitary HVAC control applications. Each controller communicates via LonWorks or BACnet MS/TP network communications. Each controller provides flexible, universal inputs for external sensors, digital inputs, and a combination of analog outputs and digital Triac outputs. The Sylk Bus is included in each controller which enables connection to other Sylk enabled devices. These controllers provide many options and advanced system features that allow state-of-the-art individual room control. Each controller is freely programmable and configurable. Direct LonWorks connection.
LonWorks(R) connection: directly connectable

Unitary Controllers without pressure sensor and without actuator
Hardware inputs: 4 universal
Hardware outputs: 2 analog, 4 digital
Power supply: 24Vac


CLLYUL6438S

Centraline Freely programmable LonWorks room controller, LYNX

The controllers are for use in VAV (Variable Air Volume) and Unitary HVAC control applications. Each controller communicates via LonWorks or BACnet MS/TP network communications. Each controller provides flexible, universal inputs for external sensors, digital inputs, and a combination of analog outputs and digital Triac outputs. The Sylk Bus is included in each controller which enables connection to other Sylk enabled devices. These controllers provide many options and advanced system features that allow state-of-the-art individual room control. Each controller is freely programmable and configurable. Direct LonWorks connection.
LonWorks(R) connection: directly connectable

Unitary Controllers without pressure sensor and without actuator
Hardware inputs: 6 universal, 4 digital
Hardware outputs: 3 analog, 8 digital
Power supply: 24Vac


CLLYVB0000AS

Centraline Freely programmable BACnet room controller, LYNX

The controllers are for use in VAV (Variable Air Volume) and Unitary HVAC control applications. Each controller communicates via LonWorks(R) or BACnet MS/TP network communications. Each controller provides flexible, universal inputs for external sensors, digital inputs, and a combination of analog outputs and digital Triac outputs. The Sylk Bus is included in each controller which enables connection to other Sylk enabled devices. These controllers provide many options and advanced system features that allow state-of-the-art individual room control. Each controller is freely programmable and configurable. Direct BACnet (MSTP) connection.

VAV controllers with pressure sensor and damper actuator 5 Nm
Hardware inputs: no
Hardware outputs: no
Power supply: 24Vac


CLLYVB4022AS

Centraline Freely programmable BACnet room controller, LYNX

The controllers are for use in VAV (Variable Air Volume) and Unitary HVAC control applications. Each controller communicates via LonWorks(R) or BACnet MS/TP network communications. Each controller provides flexible, universal inputs for external sensors, digital inputs, and a combination of analog outputs and digital Triac outputs. The Sylk Bus is included in each controller which enables connection to other Sylk enabled devices. These controllers provide many options and advanced system features that allow state-of-the-art individual room control. Each controller is freely programmable and configurable. Direct BACnet (MSTP) connection.

VAV controllers with pressure sensor and damper actuator 5 Nm
Hardware inputs: 4 universal
Hardware outputs: 2 analog, 2 digital
Power supply: 24Vac


CLLYVB4024NS

Centraline Freely programmable BACnet room controller, LYNX

The controllers are for use in VAV (Variable Air Volume) and Unitary HVAC control applications. Each controller communicates via LonWorks(R) or BACnet MS/TP network communications. Each controller provides flexible, universal inputs for external sensors, digital inputs, and a combination of analog outputs and digital Triac outputs. The Sylk Bus is included in each controller which enables connection to other Sylk enabled devices. These controllers provide many options and advanced system features that allow state-of-the-art individual room control. Each controller is freely programmable and configurable. Direct BACnet (MSTP) connection.

VAV controllers with pressure sensor and without actuator
Hardware inputs: 4 universal
Hardware outputs: 2 analog, 4 digital
Power supply: 24Vac


CLLYVB6436AS

Centraline Freely programmable BACnet room controller, LYNX

The controllers are for use in VAV (Variable Air Volume) and Unitary HVAC control applications. Each controller communicates via LonWorks(R) or BACnet MS/TP network communications. Each controller provides flexible, universal inputs for external sensors, digital inputs, and a combination of analog outputs and digital Triac outputs. The Sylk Bus is included in each controller which enables connection to other Sylk enabled devices. These controllers provide many options and advanced system features that allow state-of-the-art individual room control. Each controller is freely programmable and configurable. Direct BACnet (MSTP) connection.

VAV controllers with pressure sensor and damper actuator 5 Nm
Hardware inputs: 6 universal, 4 digital
Hardware outputs: 3 analog, 6 digital
Power supply: 24Vac


CLLYVB6438NS

Centraline Freely programmable BACnet room controller, LYNX

The controllers are for use in VAV (Variable Air Volume) and Unitary HVAC control applications. Each controller communicates via LonWorks(R) or BACnet MS/TP network communications. Each controller provides flexible, universal inputs for external sensors, digital inputs, and a combination of analog outputs and digital Triac outputs. The Sylk Bus is included in each controller which enables connection to other Sylk enabled devices. These controllers provide many options and advanced system features that allow state-of-the-art individual room control. Each controller is freely programmable and configurable. Direct BACnet (MSTP) connection.

VAV controllers with pressure sensor and without actuator
Hardware inputs: 6 universal, 4 digital
Hardware outputs: 3 analog, 8 digital
Power supply: 24Vac


CLLYVL0000AS

Centraline Freely programmable LonWorks room controller, LYNX

The controllers are for use in VAV (Variable Air Volume) and Unitary HVAC control applications. Each controller communicates via LonWorks or BACnet MS/TP network communications. Each controller provides flexible, universal inputs for external sensors, digital inputs, and a combination of analog outputs and digital Triac outputs. The Sylk Bus is included in each controller which enables connection to other Sylk enabled devices. These controllers provide many options and advanced system features that allow state-of-the-art individual room control. Each controller is freely programmable and configurable. Direct LonWorks connection.
LonWorks(R) connection: directly connectable

VAV controllers with pressure sensor and damper actuator 5 Nm
Hardware inputs: no
Hardware outputs: no
Power supply: 24Vac


CLLYVL4022AS

Centraline Freely programmable LonWorks room controller, LYNX

The controllers are for use in VAV (Variable Air Volume) and Unitary HVAC control applications. Each controller communicates via LonWorks or BACnet MS/TP network communications. Each controller provides flexible, universal inputs for external sensors, digital inputs, and a combination of analog outputs and digital Triac outputs. The Sylk Bus is included in each controller which enables connection to other Sylk enabled devices. These controllers provide many options and advanced system features that allow state-of-the-art individual room control. Each controller is freely programmable and configurable. Direct LonWorks connection.
LonWorks(R) connection: directly connectable

VAV controllers with pressure sensor and damper actuator 5 Nm
Hardware inputs: 4 universal
Hardware outputs: 2 analog, 2 digital
Power supply: 24Vac


CLLYVL4024NS

Centraline Freely programmable LonWorks room controller, LYNX

The controllers are for use in VAV (Variable Air Volume) and Unitary HVAC control applications. Each controller communicates via LonWorks or BACnet MS/TP network communications. Each controller provides flexible, universal inputs for external sensors, digital inputs, and a combination of analog outputs and digital Triac outputs. The Sylk Bus is included in each controller which enables connection to other Sylk enabled devices. These controllers provide many options and advanced system features that allow state-of-the-art individual room control. Each controller is freely programmable and configurable. Direct LonWorks connection.
LonWorks(R) connection: directly connectable

VAV controllers with pressure sensor and without actuator
Hardware inputs: 4 universal
Hardware outputs: 2 analog, 4 digital
Power supply: 24Vac


CLLYVL6436AS

Centraline Freely programmable LonWorks room controller, LYNX

The controllers are for use in VAV (Variable Air Volume) and Unitary HVAC control applications. Each controller communicates via LonWorks or BACnet MS/TP network communications. Each controller provides flexible, universal inputs for external sensors, digital inputs, and a combination of analog outputs and digital Triac outputs. The Sylk Bus is included in each controller which enables connection to other Sylk enabled devices. These controllers provide many options and advanced system features that allow state-of-the-art individual room control. Each controller is freely programmable and configurable. Direct LonWorks connection.
LonWorks(R) connection: directly connectable

VAV controllers with pressure sensor and damper actuator 5 Nm
Hardware inputs: 6 universal, 4 digital
Hardware outputs: 3 analog, 6 digital
Power supply: 24Vac


CLLYVL6438NS

Centraline Freely programmable LonWorks room controller, LYNX

The controllers are for use in VAV (Variable Air Volume) and Unitary HVAC control applications. Each controller communicates via LonWorks or BACnet MS/TP network communications. Each controller provides flexible, universal inputs for external sensors, digital inputs, and a combination of analog outputs and digital Triac outputs. The Sylk Bus is included in each controller which enables connection to other Sylk enabled devices. These controllers provide many options and advanced system features that allow state-of-the-art individual room control. Each controller is freely programmable and configurable. Direct LonWorks connection.
LonWorks(R) connection: directly connectable

VAV controllers with pressure sensor and without actuator
Hardware inputs: 6 universal, 4 digital
Hardware outputs: 3 analog, 8 digital
Power supply: 24Vac


CLMERL2

Centraline Configurable BACnet room controller MERLIN

The MERLIN (CLMERRxx) family of room controllers provide flexible,configurable, demand-led control delivering tangible benefits to reduce energy spends and drives new levels of functionality and efficiency in todays buildings. These BACnet MS/TP based room controllers are configured through the CL-ROOMUP app, supporting fan coil unit, air quality control, underfloor heating, chilled and hot ceiling as well as radiator heating applications. It is even possible to handle a mix of these applications in one controller.
Line voltage power supply and the flexible use of relays and triacs (24 VAC or 230 VAC), 24 VAC power supply for field devices, Sylk wall modules, and smart engineering and commissioning tools reduce the total installed cost.
Hardware inputs: a variety of sensors (e.g., room temperature sensors, supply temperature sensors, humidity sensors, window sensors, occupancy sensors, and card readers) may be used
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays with input and output terminal per relay support flexible use (N.O.)
triacs with common input terminals(24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell Room HMIs CLCMTR40x/TR42x
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)
Relay outputs: 4
Control software: configurable

LARGE Housing (189x110x57,5mm)
AO: 2
UI: 6
Triac: 4
Power supply: 230Vac


CLMERL6

Centraline Configurable BACnet room controller MERLIN

The MERLIN (CLMERRxx) family of room controllers provide flexible,configurable, demand-led control delivering tangible benefits to reduce energy spends and drives new levels of functionality and efficiency in todays buildings. These BACnet MS/TP based room controllers are configured through the CL-ROOMUP app, supporting fan coil unit, air quality control, underfloor heating, chilled and hot ceiling as well as radiator heating applications. It is even possible to handle a mix of these applications in one controller.
Line voltage power supply and the flexible use of relays and triacs (24 VAC or 230 VAC), 24 VAC power supply for field devices, Sylk wall modules, and smart engineering and commissioning tools reduce the total installed cost.
Hardware inputs: a variety of sensors (e.g., room temperature sensors, supply temperature sensors, humidity sensors, window sensors, occupancy sensors, and card readers) may be used
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays with input and output terminal per relay support flexible use (N.O.)
triacs with common input terminals(24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell Room HMIs CLCMTR40x/TR42x
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)
Relay outputs: 4
Control software: configurable

LARGE Housing (189x110x57,5mm)
AO: 6
UI: 10
Triac: 4
Power supply: 24Vac


CLMERL8

Centraline Configurable BACnet room controller MERLIN

The MERLIN (CLMERRxx) family of room controllers provide flexible,configurable, demand-led control delivering tangible benefits to reduce energy spends and drives new levels of functionality and efficiency in todays buildings. These BACnet MS/TP based room controllers are configured through the CL-ROOMUP app, supporting fan coil unit, air quality control, underfloor heating, chilled and hot ceiling as well as radiator heating applications. It is even possible to handle a mix of these applications in one controller.
Line voltage power supply and the flexible use of relays and triacs (24 VAC or 230 VAC), 24 VAC power supply for field devices, Sylk wall modules, and smart engineering and commissioning tools reduce the total installed cost.
Hardware inputs: a variety of sensors (e.g., room temperature sensors, supply temperature sensors, humidity sensors, window sensors, occupancy sensors, and card readers) may be used
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays with input and output terminal per relay support flexible use (N.O.)
triacs with common input terminals(24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell Room HMIs CLCMTR40x/TR42x
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)
Relay outputs: 4
Control software: configurable

LARGE Housing (189x110x57,5mm)
AO: 6
UI: 10
Triac: 4
Power supply: 230Vac


CLMERS4

Centraline Configurable BACnet room controller MERLIN

The MERLIN (CLMERRxx) family of room controllers provide flexible,configurable, demand-led control delivering tangible benefits to reduce energy spends and drives new levels of functionality and efficiency in todays buildings. These BACnet MS/TP based room controllers are configured through the CL-ROOMUP app, supporting fan coil unit, air quality control, underfloor heating, chilled and hot ceiling as well as radiator heating applications. It is even possible to handle a mix of these applications in one controller.
Line voltage power supply and the flexible use of relays and triacs (24 VAC or 230 VAC), 24 VAC power supply for field devices, Sylk wall modules, and smart engineering and commissioning tools reduce the total installed cost.
Hardware inputs: a variety of sensors (e.g., room temperature sensors, supply temperature sensors, humidity sensors, window sensors, occupancy sensors, and card readers) may be used
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays with input and output terminal per relay support flexible use (N.O.)
triacs with common input terminals(24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell Room HMIs CLCMTR40x/TR42x
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)
Relay outputs: 4
Control software: configurable

SMALL Housing (162x110x57,5mm)
AO: 4
UI: 4
Triac: 2
Power supply: 230Vac


CLMERS5

Centraline Configurable BACnet room controller MERLIN

The MERLIN (CLMERRxx) family of room controllers provide flexible,configurable, demand-led control delivering tangible benefits to reduce energy spends and drives new levels of functionality and efficiency in todays buildings. These BACnet MS/TP based room controllers are configured through the CL-ROOMUP app, supporting fan coil unit, air quality control, underfloor heating, chilled and hot ceiling as well as radiator heating applications. It is even possible to handle a mix of these applications in one controller.
Line voltage power supply and the flexible use of relays and triacs (24 VAC or 230 VAC), 24 VAC power supply for field devices, Sylk wall modules, and smart engineering and commissioning tools reduce the total installed cost.
Hardware inputs: a variety of sensors (e.g., room temperature sensors, supply temperature sensors, humidity sensors, window sensors, occupancy sensors, and card readers) may be used
contact status from occupancy sensors, window switches, condensation contacts etc.
Hardware outputs: relays with input and output terminal per relay support flexible use (N.O.)
triacs with common input terminals(24/230Vac)
Bus system description: BACnet MS/TP communication between controllers
Sylk bus to Honeywell Room HMIs CLCMTR40x/TR42x
RJ45 connector for BACnet WiFi adapter
Mounting: DIN rail
in cabinets
fuse boxes
on walls
Protection class: IP20 (IP30 with optional terminal cover)
Relay outputs: 4
Control software: configurable

SMALL Housing (162x110x57,5mm)
AO: 4
UI: 4
Triac: 2
Power supply: 24Vac


CLMMI00N22

Centraline CentraLine External MMI

MMI with a backlit LCD screen capable of displaying West European, East European, Turkish, and Cyrillic characters. Suitable for use as a desk-top device or for installation in a cabinet door. Bus-wide access to all CentraLine plant controllers on the same bus.
Kit supplied for panel door mounting (IP54)


CLMMI00N31

Centraline Programmable universal BACnet Building Controller, EAGLE
Additional product for controllers

CentraLine Touch operator interface



CLNX-100N-SMA-1Y

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX maintenance licenses for node licenses
Model: SUP-100N maintenance 1 year extension


CLNX-100N-SMA-3Y

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX maintenance licenses for node licenses
Model: SUP-100N maintenance 3 year extension


CLNX-100N-SMA-5Y

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX maintenance licenses for node licenses
Model: SUP-100N maintenance 5 year extension


CLNX-10N-SMA-1Y

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX maintenance licenses for node licenses
Model: SUP-10N maintenance 1 year extension


CLNX-10N-SMA-3Y

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX maintenance licenses for node licenses
Model: SUP-10N maintenance 3 year extension


CLNX-10N-SMA-5Y

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX maintenance licenses for node licenses
Model: SUP-10N maintenance 5 year extension


CLNX-1N-SMA-1Y

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX maintenance licenses for node licenses
Model: SUP-1N maintenance 1 year extension


CLNX-1N-SMA-3Y

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX maintenance licenses for node licenses
Model: SUP-1N maintenance 3 year extension


CLNX-1N-SMA-5Y

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX maintenance licenses for node licenses
Model: SUP-1N maintenance 5 year extension


CLNX-DEVICE-UP-10

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000 point upgrade licenses
Product description: Plus 500 points upgrade


CLNX-DEVICE-UP-25

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000 point upgrade licenses
Product description: Plus 1250 points upgrade


CLNX-DEVICE-UP-50

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000 point upgrade licenses
Product description: Plus 2500 points upgrade


CLNX-DR-MFID

Centraline Connected Building Management, HAWK 8000
HAWK 8000 Communication drivers

HAWK 8000 Fidelio driver



CLNX-DR-S-CSV

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

Optional ARENA NX database drivers for external database applications
Model: Driver for CSV database


CLNX-DR-S-MYSQL

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

Optional ARENA NX database drivers for external database applications
Model: Driver for SQL database


CLNX-DR-S-SQL

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

Optional ARENA NX database drivers for external database applications
Model: Driver for MYSQL database


CLNX-DR-SMS-ALM

Centraline Connected Building Management, HAWK 8000
HAWK 8000 Communication drivers

HAWK 8000 SMS driver



CLNX-P-SMA-1Y

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX maintenance licenses for point licenses
Model: SUP-P maintenance 3 year extension


CLNX-P-SMA-5Y

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX maintenance licenses for point licenses
Model: SUP-P maintenance 5 year extension


CLNX-S-10000P

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX part numbers with open point licenses
Model: NX Supervisor with 10000 open points


CLNX-S-10000P-UP

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX Upgrade Licenses
Model: Add driver capacity 10000 points


CLNX-S-100N

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX part numbers based on NIAGARA nodes
Model: Supervisor - 100 HAWK / EAGLHAWK


CLNX-S-100N-UP

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX Upgrade Licenses
Model: Upgrade to 100 HAWK / EAGLEHAWK


CLNX-S-10N

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX part numbers based on NIAGARA nodes
Model: Supervisor - 10 HAWK / EAGLHAWK


CLNX-S-10N-UP

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX Upgrade Licenses
Model: Add 10 HAWK / EAGLEHAWK


CLNX-S-1N-UP

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX Upgrade Licenses
Model: Add 1 HAWK / EAGLEHAWK


CLNX-S-2500P

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX part numbers with open point licenses
Model: NX Supervisor with 2500 open points


CLNX-S-2500P-UP

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX Upgrade Licenses
Model: Add driver capacity 2500 points


CLNX-S-50000P

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX part numbers with open point licenses
Model: NX Supervisor with 50000 open points


CLNX-S-50000P-UP

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX Upgrade Licenses
Model: Add driver capacity 50000 points


CLNX-S-5000P

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX part numbers with open point licenses
Model: NX Supervisor with 5000 open points


CLNX-S-5000P-UP

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX Upgrade Licenses
Model: Add driver capacity 5000 points


CLNX-S-500P

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX part numbers with open point licenses
Model: NX Supervisor with 500 open points


CLNX-S-500P-UP

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX Upgrade Licenses
Model: Add driver capacity 500 points


CLNX-S-5N

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX part numbers based on NIAGARA nodes
Model: Supervisor - 5 HAWK / EAGLHAWK


CLNX-S-UNL

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX part numbers based on NIAGARA nodes
Model: Supervisor - unlimited HAWK / EAGLHAWK - only on request


CLNX-SMA-80010-1YR

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000 software update licenses
Product description: 1 year software update for 500-1249 points


CLNX-SMA-8005-1YR

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000 software update licenses
Product description: 1 year software update for 250-499 points


CLNX-SMA-8005-3YR

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000 software update licenses
Product description: 3 year software update for 250-499 points


CLNX-SMA-8005-5YR

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000 software update licenses
Product description: 5 year software update for 250-499 points


CLNX-SMA-8010-3YR

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000 software update licenses
Product description: 3 year software update for 500-1249 points


CLNX-SMA-8010-5YR

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000 software update licenses
Product description: 5 year software update for 500-1249 points


CLNX-SMA-8025-1YR

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000 software update licenses
Product description: 1 year software update for 1250-4999 points


CLNX-SMA-8025-3YR

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000 software update licenses
Product description: 3 year software update for 1250-4999 points


CLNX-SMA-8025-5YR

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000 software update licenses
Product description: 5 year software update for 1250-4999 points


CLNX-SMA-8100-1YR

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000 software update licenses
Product description: 1 year software update for 5000-9999 points


CLNX-SMA-8100-3YR

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000 software update licenses
Product description: 3 year software update for 5000-9999 points


CLNX-SMA-8100-5YR

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000 software update licenses
Product description: 5 year software update for 5000-9999 points


CLNX-SMA-8200-1YR

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000 software update licenses
Product description: 1 year software update for 10000+ points


CLNX-SMA-8200-3YR

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000 software update licenses
Product description: 3 year software update for 10000+ points


CLNX-SMA-8200-5YR

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000 software update licenses
Product description: 5 year software update for 10000+ points


CLNX-UNL-SMA-1Y

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX maintenance licenses for node licenses
Model: SUP-UNLN maintenance 3 year extension


CLNX-UNL-SMA-5Y

Centraline Web based Supervisor software, ARENA NX

ARENA NX is a web-based building monitoring and management solution build upon the powerful Niagara 4 platform. It is capable of integrating CentraLine BACnet and Niagara controllers, third party devices and internet protocols into a centralized software platform that is designed to manage buildings at an enterprise level. It is used to supervise HVAC systems and non-HVAC systems (e.g. lighting, security, life safety) in a building or across multiple buildings.
ARENA NX serves real time graphical information to standard web-browser clients and also provides server-level functions such as: centralized data logging, archiving, alarming, real time graphical displays, master scheduling, system-wide database management, and integration with enterprise software applications. ARENA NX helps to maximize operating and services opportunities and to minimize associated costs.
The comprehensive graphical engineering tool set (COACH NX) is embedded in the ARENA NX. COACH NX is the single engineering tool for HAWK and ARENA NX.
Features:
WEB ACCESS Access to alarms, graphics, schedules, logs and configuration data with a web browser and mobile devices
REAL TIME GRAPHICAL DISPLAY Free configurable HTML5 user interface. Supported by libraries and template functions for an efficient user interface engineering
ALARMING Sophisticated alarm segregation, processing, escalation and routing, including e-mail alarm acknowledging
CONNECTIVITY BACnet driver with server and client support. C-Bus, Modbus IP, LON IP, MBUS, KNX IP, OPC and SNMP drivers supported by open point license
SCHEDULING Read / write access to BACnet, C-Bus and Niagara schedules. Global schedule and calendar functions Scheduling on Supervisor support to manage device without internal schedule function
CENTRALIZED DATA LOGGING All points can be added to a history database. Interval and Change Of Value (COV) algorithms are supported. History data can be visualized in easy and intuitive way
ENERGYMANAGEMENT Basic energy management functions are included, enhanced features can be added. CentraLine ENERGYVISION is an extension module to the supervisor
AUDIT Audit Trail of database changes, database storage and backup, global time functions, calendar, central scheduling, control and energy management routines
NAVIGATION Navigation can easily be adjusted to End-User permissions and needs
SCRIPTING / LOGIC Freely programmed scripts and logic can be used to implement control and management functions on supervisor level. Batch functions can be executed to force actions or adjust settings across the system
PLANT CONTROLLER support Supports multiple HAWK / EAGLEHAWK and EAGLE controllers connected to a local Ethernet network, or the Internet. Remote back up of HAWK applications to Supervisor
CONFIGURABLE ROOM CONTROLLER support Supports template for efficient configuration of MERLIN application. BACnet parameter have not to be considered as license points
META DATA support (Tagging) Additional information can be added to all integrated objects. Those information can be used to structure data, search data and prepare data for further analytics
DOCUMENTATION Full Supervisor documentation on "one click"
DASHBOARDING Data summary views customizable by End-Users
SEARCH Find data quickly, by using the clear text search function
SECURITY Password protection and security using authentication and encryption techniques with optional security supported via an external LDAP connection
USERS Supports an unlimited number of users via Internet / Intranet access with a standard web browser, depending on the host PC / Server resources
ARCHIVING Optional enterprise-level data archival using SQL and, MySQL database and XML, CSV or text formats
REPORTING Define reports which can be manually or automatically be created as pdf or csv file and attached to email

ARENA NX maintenance licenses for node licenses
Model: SUP-UNLN maintenance 5 year extension


CLNXHAWK8-100

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000, without WIFI
Product description: HAWK 8000, no WIFI, 100 points, one year software update


CLNXHAWK8-10K

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000, without WIFI
Product description: HAWK 8000, no WIFI, 10000 points, one year software update


CLNXHAWK8-1250

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000, without WIFI
Product description: HAWK 8000, no WIFI, 1250 points, one year software update


CLNXHAWK8-250

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000, without WIFI
Product description: HAWK 8000, no WIFI, 250 points, one year software update


CLNXHAWK8-500

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000, without WIFI
Product description: HAWK 8000, no WIFI, 500 points, one year software update


CLNXHAWK8-5K

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000, without WIFI
Product description: HAWK 8000, no WIFI, 5000 points, one year software update


CLNXHAWK8-CLIP

Centraline Connected Building Management, HAWK 8000
HAWK 8000 Spare parts

HAWK 8000 CentraLine clip



CLNXHAWK8-SD

Centraline Connected Building Management, HAWK 8000
HAWK 8000 Spare parts

HAWK 8000 SD CARD



CLNXHAWK8W02-100

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000, with WIFI
Product description: HAWK 8000, with WIFI, 100 points, one year software update


CLNXHAWK8W02-10K

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000, with WIFI
Product description: HAWK 8000, with WIFI, 10000 points, one year software update


CLNXHAWK8W02-1250

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000, with WIFI
Product description: HAWK 8000, with WIFI, 1250 points, one year software update


CLNXHAWK8W02-250

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000, with WIFI
Product description: HAWK 8000, with WIFI, 250 points, one year software update


CLNXHAWK8W02-500

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000, with WIFI
Product description: HAWK 8000, with WIFI, 500 points, one year software update


CLNXHAWK8W02-5K

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000, with WIFI
Product description: HAWK 8000, with WIFI, 5000 points, one year software update


CLNXSERIES8

Centraline Connected Building Management, HAWK 8000
HAWK 8000 Spare parts

HAWK 8000, no WIFI, without license



CLNXSERIES8W02

Centraline Connected Building Management, HAWK 8000
HAWK 8000 Spare parts

HAWK 8000, with WIFI, without license



CLPA13LC02

Centraline HVAC controller with configurable applications, PANTHER

CentraLine controller for HVAC applications The controller can be applied for stand-alone operation, dial-up and in network systems.
Control software: Free programmable with CARE software or configurable with COACH engineering tool. Application card with control software, with hundreds of different selectable applications and parameter settings.
Hardware inputs: Analog Inputs (AI) for NTC20k sensors
Digital Inputs (DI) for potential free contacts or 24 Vdc
Hardware outputs: Analogue Outputs (AO) 0..10 Vdc
Digital Outputs (DO) 24 Vac
Management applications: ARENA 3.00
Stand-alone operation: yes
Bus system description: LonWorks(R) bus for data exchange with other PANTHER, or TIGER controllers, and building automation management systems with ARENA, or alarm monitoring with RANGER
models available with C-bus, for data exchange with other PANTHER or MCR200 controllers (max. 30 devices per bus)
Transceiver type: LonWorks(R) FTT10A
Application cards: with removable card for communication, application storage, operating system and local language texts for operator panel
Mounting: DIN rail or cabinet front door
Protection class: IP30, IP54 with door mounting accessories (supplied)
Type of terminals: screw terminals with terminal block
Memory back-up: goldcap capacitor for 72 hours RAM and real-time clock buffering
Power supply: 24Vac
C-bus connection: directly connectable via application card
LonWorks(R) connection: directly connectable via application card
Use CARE software for free programming or COACH software to select the right control application for the required installation.

Mini PANTHER controller; 4 AI, 4 DI, 2 AO, 3 DO
Product description: Mini PANTHER controller with LON + C-Bus


CLPA13LC12

Centraline HVAC controller with configurable applications, PANTHER

CentraLine controller for HVAC applications The controller can be applied for stand-alone operation, dial-up and in network systems.
Control software: Free programmable with CARE software or configurable with COACH engineering tool. Application card with control software, with hundreds of different selectable applications and parameter settings.
Hardware inputs: Analog Inputs (AI) for NTC20k sensors
Digital Inputs (DI) for potential free contacts or 24 Vdc
Hardware outputs: Analogue Outputs (AO) 0..10 Vdc
Digital Outputs (DO) 24 Vac
Management applications: ARENA 3.00
Stand-alone operation: yes
Bus system description: LonWorks(R) bus for data exchange with other PANTHER, or TIGER controllers, and building automation management systems with ARENA, or alarm monitoring with RANGER
models available with C-bus, for data exchange with other PANTHER or MCR200 controllers (max. 30 devices per bus)
Transceiver type: LonWorks(R) FTT10A
Application cards: with removable card for communication, application storage, operating system and local language texts for operator panel
Mounting: DIN rail or cabinet front door
Protection class: IP30, IP54 with door mounting accessories (supplied)
Type of terminals: screw terminals with terminal block
Memory back-up: goldcap capacitor for 72 hours RAM and real-time clock buffering
Power supply: 24Vac
C-bus connection: directly connectable via application card
LonWorks(R) connection: directly connectable via application card
Use CARE software for free programming or COACH software to select the right control application for the required installation.

Mini PANTHER controller; 4 AI, 4 DI, 2 AO, 3 DO
Product description: Mini PANTHER controller with LON + C-Bus + operator panel


CLPA21LC02

Centraline HVAC controller with configurable applications, PANTHER

CentraLine controller for HVAC applications The controller can be applied for stand-alone operation, dial-up and in network systems.
Control software: Free programmable with CARE software or configurable with COACH engineering tool. Application card with control software, with hundreds of different selectable applications and parameter settings.
Hardware inputs: Analog Inputs (AI) for NTC20k sensors
Digital Inputs (DI) for potential free contacts or 24 Vdc
Hardware outputs: Analogue Outputs (AO) 0..10 Vdc
Digital Outputs (DO) 24 Vac
Management applications: ARENA 3.00
Stand-alone operation: yes
Bus system description: LonWorks(R) bus for data exchange with other PANTHER, or TIGER controllers, and building automation management systems with ARENA, or alarm monitoring with RANGER
models available with C-bus, for data exchange with other PANTHER or MCR200 controllers (max. 30 devices per bus)
Transceiver type: LonWorks(R) FTT10A
Application cards: with removable card for communication, application storage, operating system and local language texts for operator panel
Mounting: DIN rail or cabinet front door
Protection class: IP30, IP54 with door mounting accessories (supplied)
Type of terminals: screw terminals with terminal block
Memory back-up: goldcap capacitor for 72 hours RAM and real-time clock buffering
Power supply: 24Vac
C-bus connection: directly connectable via application card
LonWorks(R) connection: directly connectable via application card
Use CARE software for free programming or COACH software to select the right control application for the required installation.

PANTHER controller; 8 AI, 4 DI, 4 AO, 6 DO
Product description: PANTHER controller with LON + C-Bus


CLPA21LC12

Centraline HVAC controller with configurable applications, PANTHER

CentraLine controller for HVAC applications The controller can be applied for stand-alone operation, dial-up and in network systems.
Control software: Free programmable with CARE software or configurable with COACH engineering tool. Application card with control software, with hundreds of different selectable applications and parameter settings.
Hardware inputs: Analog Inputs (AI) for NTC20k sensors
Digital Inputs (DI) for potential free contacts or 24 Vdc
Hardware outputs: Analogue Outputs (AO) 0..10 Vdc
Digital Outputs (DO) 24 Vac
Management applications: ARENA 3.00
Stand-alone operation: yes
Bus system description: LonWorks(R) bus for data exchange with other PANTHER, or TIGER controllers, and building automation management systems with ARENA, or alarm monitoring with RANGER
models available with C-bus, for data exchange with other PANTHER or MCR200 controllers (max. 30 devices per bus)
Transceiver type: LonWorks(R) FTT10A
Application cards: with removable card for communication, application storage, operating system and local language texts for operator panel
Mounting: DIN rail or cabinet front door
Protection class: IP30, IP54 with door mounting accessories (supplied)
Type of terminals: screw terminals with terminal block
Memory back-up: goldcap capacitor for 72 hours RAM and real-time clock buffering
Power supply: 24Vac
C-bus connection: directly connectable via application card
LonWorks(R) connection: directly connectable via application card
Use CARE software for free programming or COACH software to select the right control application for the required installation.

PANTHER controller; 8 AI, 4 DI, 4 AO, 6 DO
Product description: PANTHER controller with LON + C-Bus + operator panel


CLPA21LC22

Centraline HVAC controller with configurable applications, PANTHER

CentraLine controller for HVAC applications The controller can be applied for stand-alone operation, dial-up and in network systems.
Control software: Free programmable with CARE software or configurable with COACH engineering tool. Application card with control software, with hundreds of different selectable applications and parameter settings.
Hardware inputs: Analog Inputs (AI) for NTC20k sensors
Digital Inputs (DI) for potential free contacts or 24 Vdc
Hardware outputs: Analogue Outputs (AO) 0..10 Vdc
Digital Outputs (DO) 24 Vac
Management applications: ARENA 3.00
Stand-alone operation: yes
Bus system description: LonWorks(R) bus for data exchange with other PANTHER, or TIGER controllers, and building automation management systems with ARENA, or alarm monitoring with RANGER
models available with C-bus, for data exchange with other PANTHER or MCR200 controllers (max. 30 devices per bus)
Transceiver type: LonWorks(R) FTT10A
Application cards: with removable card for communication, application storage, operating system and local language texts for operator panel
Mounting: DIN rail or cabinet front door
Protection class: IP30, IP54 with door mounting accessories (supplied)
Type of terminals: screw terminals with terminal block
Memory back-up: goldcap capacitor for 72 hours RAM and real-time clock buffering
Power supply: 24Vac
C-bus connection: directly connectable via application card
LonWorks(R) connection: directly connectable via application card
Use CARE software for free programming or COACH software to select the right control application for the required installation.

PANTHER controller; 8 AI, 4 DI, 4 AO, 6 DO
Product description: PANTHER controller with LON + C-Bus + operator panel Cyrillic


CLSE1L230

Centraline Zone controller, SERVAL

Room temperature controller for 2- and 4-pipe fan coil units, radiators, floorheating and chilled ceiling.
For heater, cooler, electric re-heat and 1,2,3-speed fans.
Heating output signal: triacs (500 mA) configurable for thermal, 3-pt or PWM control
Cooling output signal: triacs (500 mA) configurable for thermal or 3-pt control
Fan output signal: 3 relays (250V~, 3A)
Re-heat output signal: relay (250V~, 10A) (6A UL916)
Control functions: heat only, cool only, heat/cool change over, heat and cool in sequence; in addition electrical reheat; zero energy band
Modes of operations: occupied, standby, unoccupied, open window, frost protection, smoke control, fan fail, summer/winter change over
Obligatory inputs: 1 temperature input for CentraLine wall module
Optional inputs: configurable with COACH:
1 digital input configurable for: window or occupancy or or movement or change over or airflow
1 digital input for window contact
Stand-alone operation: yes
Network operation: yes
Bus system: LonWorks(R)
LonMark(R) profile: 8020
Use COACH software from CentraLine to select the right control software for the required installation.


Power supply: 230Vac
Re-heat output: yes
Triac outputs 24Vac: no
Triac outputs 230Vac: 4x for heat/cool
Auxiliary output signal: no
Note: no


CLSE1L24

Centraline Zone controller, SERVAL

Room temperature controller for 2- and 4-pipe fan coil units, radiators, floorheating and chilled ceiling.
For heater, cooler, electric re-heat and 1,2,3-speed fans.
Heating output signal: triacs (500 mA) configurable for thermal, 3-pt or PWM control
Cooling output signal: triacs (500 mA) configurable for thermal or 3-pt control
Fan output signal: 3 relays (250V~, 3A)
Re-heat output signal: relay (250V~, 10A) (6A UL916)
Control functions: heat only, cool only, heat/cool change over, heat and cool in sequence; in addition electrical reheat; zero energy band
Modes of operations: occupied, standby, unoccupied, open window, frost protection, smoke control, fan fail, summer/winter change over
Obligatory inputs: 1 temperature input for CentraLine wall module
Optional inputs: configurable with COACH:
1 digital input configurable for: window or occupancy or or movement or change over or airflow
1 digital input for window contact
Stand-alone operation: yes
Network operation: yes
Bus system: LonWorks(R)
LonMark(R) profile: 8020
Use COACH software from CentraLine to select the right control software for the required installation.


Power supply: 24Vac
Re-heat output: yes
Triac outputs 24Vac: 4x for heat/cool
Triac outputs 230Vac: no
Auxiliary output signal: no
Note: no


CLSE2L230

Centraline Zone controller, SERVAL

Room temperature controller for 2- and 4-pipe fan coil units, radiators, floorheating and chilled ceiling.
For heater, cooler, electric re-heat and 1,2,3-speed fans.
Heating output signal: triacs (500 mA) configurable for thermal, 3-pt or PWM control
Cooling output signal: triacs (500 mA) configurable for thermal or 3-pt control
Fan output signal: 3 relays (250V~, 3A)
Re-heat output signal: relay (250V~, 10A) (6A UL916)
Control functions: heat only, cool only, heat/cool change over, heat and cool in sequence; in addition electrical reheat; zero energy band
Modes of operations: occupied, standby, unoccupied, open window, frost protection, smoke control, fan fail, summer/winter change over
Obligatory inputs: 1 temperature input for CentraLine wall module
Optional inputs: configurable with COACH:
1 digital input configurable for: window or occupancy or or movement or change over or airflow
1 digital input for window contact
Stand-alone operation: yes
Network operation: yes
Bus system: LonWorks(R)
LonMark(R) profile: 8020
Use COACH software from CentraLine to select the right control software for the required installation.


Power supply: 230Vac
Re-heat output: yes
Triac outputs 24Vac: no
Triac outputs 230Vac: 4x for heat/cool
Auxiliary output signal: AO variable speed fan
Note: no


CLSE2L24

Centraline Zone controller, SERVAL

Room temperature controller for 2- and 4-pipe fan coil units, radiators, floorheating and chilled ceiling.
For heater, cooler, electric re-heat and 1,2,3-speed fans.
Heating output signal: triacs (500 mA) configurable for thermal, 3-pt or PWM control
Cooling output signal: triacs (500 mA) configurable for thermal or 3-pt control
Fan output signal: 3 relays (250V~, 3A)
Re-heat output signal: relay (250V~, 10A) (6A UL916)
Control functions: heat only, cool only, heat/cool change over, heat and cool in sequence; in addition electrical reheat; zero energy band
Modes of operations: occupied, standby, unoccupied, open window, frost protection, smoke control, fan fail, summer/winter change over
Obligatory inputs: 1 temperature input for CentraLine wall module
Optional inputs: configurable with COACH:
1 digital input configurable for: window or occupancy or or movement or change over or airflow
1 digital input for window contact
Stand-alone operation: yes
Network operation: yes
Bus system: LonWorks(R)
LonMark(R) profile: 8020
Use COACH software from CentraLine to select the right control software for the required installation.


Power supply: 230Vac
Re-heat output: yes
Triac outputs 24Vac: 4x for heat/cool
Triac outputs 230Vac: no
Auxiliary output signal: AO variable speed fan
Note: Aux. supply field devices


CLSE3L230

Centraline Zone controller, SERVAL

Room temperature controller for 2- and 4-pipe fan coil units, radiators, floorheating and chilled ceiling.
For heater, cooler, electric re-heat and 1,2,3-speed fans.
Heating output signal: triacs (500 mA) configurable for thermal, 3-pt or PWM control
Cooling output signal: triacs (500 mA) configurable for thermal or 3-pt control
Fan output signal: 3 relays (250V~, 3A)
Re-heat output signal: relay (250V~, 10A) (6A UL916)
Control functions: heat only, cool only, heat/cool change over, heat and cool in sequence; in addition electrical reheat; zero energy band
Modes of operations: occupied, standby, unoccupied, open window, frost protection, smoke control, fan fail, summer/winter change over
Obligatory inputs: 1 temperature input for CentraLine wall module
Optional inputs: configurable with COACH:
1 digital input configurable for: window or occupancy or or movement or change over or airflow
1 digital input for window contact
Stand-alone operation: yes
Network operation: yes
Bus system: LonWorks(R)
LonMark(R) profile: 8020
Use COACH software from CentraLine to select the right control software for the required installation.


Power supply: 230Vac
Re-heat output: no
Triac outputs 24Vac: no
Triac outputs 230Vac: 2x for heat/cool, thermal control only
Auxiliary output signal: no
Note: no


CLTG00MMIN01

Centraline HVAC controller with configurable applications, and relay outputs, TIGER
Additional products for CLTG38L01

External operator panel with door mounting kit and flat cable (1.5 m)



CLTG38EXPN01

Centraline HVAC controller with configurable applications, and relay outputs, TIGER
Additional products for TIGER controllers

I/O expansion board, 8 AI, 14 DI, 4 AO, 12 DO (3 SPDT, 9 SPST) with DIN rail mounting clip and flat cable (350 mm). Max. 1 board/controller.



CLTG38L01

Centraline HVAC controller with configurable applications, and relay outputs, TIGER

CentraLine controller with relay outputs, for HVAC applications. The controller can be applied for stand-alone operation, dial-up and in network systems.
Control software: control software embedded, with hundreds of different selectable applications and parameter settings
Hardware inputs: Analog Inputs (AI) for NTC20k sensors, 0..10 V, 0/4..20 mA active sensors (apply signal separator!) or slow switching dry contact
Digital Inputs (DI) for potential free contacts, 24 Vdc or 24 Vac
Hardware outputs: Analogue Outputs (AO) 0..10V=
Digital Outputs (DO) relay contact SPDT or SPST
Management applications: ARENA / RANGER
Stand-alone operation: yes
Bus system description: LonWorks(R) bus for data exchange with other TIGER, or PANTHER controllers, and building automation management systems with ARENA, or alarm monitoring with RANGER
Transceiver type: LonWorks(R) FTT10A
Mounting: DIN rail
Protection class: IP30
Type of terminals: screw terminals with terminal block
Memory back-up: goldcap capacitor for 72 hours buffer
Power supply: 24Vac
LonWorks(R) connection: directly connectable
Use COACH software from CentraLine to select the right control software for the required installation.

TIGER controller; 8 AI, 14 DI, 4 AO, 12 DO (3 SPDT, 9 SPST)
Product description: TIGER controller with LON


CLTG38L11

Centraline HVAC controller with configurable applications, and relay outputs, TIGER

CentraLine controller with relay outputs, for HVAC applications. The controller can be applied for stand-alone operation, dial-up and in network systems.
Control software: control software embedded, with hundreds of different selectable applications and parameter settings
Hardware inputs: Analog Inputs (AI) for NTC20k sensors, 0..10 V, 0/4..20 mA active sensors (apply signal separator!) or slow switching dry contact
Digital Inputs (DI) for potential free contacts, 24 Vdc or 24 Vac
Hardware outputs: Analogue Outputs (AO) 0..10V=
Digital Outputs (DO) relay contact SPDT or SPST
Management applications: ARENA / RANGER
Stand-alone operation: yes
Bus system description: LonWorks(R) bus for data exchange with other TIGER, or PANTHER controllers, and building automation management systems with ARENA, or alarm monitoring with RANGER
Transceiver type: LonWorks(R) FTT10A
Mounting: DIN rail
Protection class: IP30
Type of terminals: screw terminals with terminal block
Memory back-up: goldcap capacitor for 72 hours buffer
Power supply: 24Vac
LonWorks(R) connection: directly connectable
Use COACH software from CentraLine to select the right control software for the required installation.

TIGER controller; 8 AI, 14 DI, 4 AO, 12 DO (3 SPDT, 9 SPST)
Product description: TIGER controller with LON + operator panel


CMS927B1015

Centraline RF underfloor heating zone control system HCE80
Additional Control units

Wireless programmable control unit with 7-day clock for usage with HCE80, CM927, BDR91



COMP-IP21-KIT1

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

HVAC232/402 IP20 to IP21 upgrade kits
Product description: IP21 enclosure upgrade kit for SmartDrive Compact size MI1
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


COMP-IP21-KIT2

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

HVAC232/402 IP20 to IP21 upgrade kits
Product description: IP21 enclosure upgrade kit for SmartDrive Compact size MI2
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


COMP-IP21-KIT3

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

HVAC232/402 IP20 to IP21 upgrade kits
Product description: IP21 enclosure upgrade kit for SmartDrive Compact size MI3
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


COMP-LOADER

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

SmartDrive PC connection tools and cables
Product description: SmartDrive Compact Parameter download/upload and PC interface tool with cable for USB connection to PC
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


COMP-LOADER-NC

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

SmartDrive PC connection tools and cables
Product description: SmartDrive Compact Parameter download/upload and PC interface tool without cable
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


COMP-NEMA1-KIT1

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

HVAC232/402 IP20 to IP21 upgrade kits
Product description: IP21 enclosure upgrade kit with additional wiring terminal cover for SmartDrive Compact size MI1
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


COMP-NEMA1-KIT2

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

HVAC232/402 IP20 to IP21 upgrade kits
Product description: IP21 enclosure upgrade kit with additional wiring terminal cover for SmartDrive Compact size MI2
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


COMP-NEMA1-KIT3

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

HVAC232/402 IP20 to IP21 upgrade kits
Product description: IP21 enclosure upgrade kit with additional wiring terminal cover for SmartDrive Compact size MI3
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


COMP230-1P1-20

Centraline Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

208..240V, 1 phase
Voltage: 230V
Low overload (for Fan/Pump): 1.1kW
Low overload Icont: 4.8A
High overload (for Machines): 1.1kW
High overload Icont: 4.8A
Brake chopper: no
1 phase input: yes
3 phases input: no


COMP230-1P5-20

Centraline Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

208..240V, 1 phase
Voltage: 230V
Low overload (for Fan/Pump): 1.5kW
Low overload Icont: 7A
High overload (for Machines): 1.5kW
High overload Icont: 7A
Brake chopper: no
1 phase input: yes
3 phases input: no


COMP230-2P2-20

Centraline Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

208..240V, 1 phase
Voltage: 230V
Low overload (for Fan/Pump): 2.2kW
Low overload Icont: 9.6A
High overload (for Machines): 2.2kW
High overload Icont: 9.6A
Brake chopper: no
1 phase input: yes
3 phases input: no


COMP230-P37-20

Centraline Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

208..240V, 1 phase
Voltage: 230V
Low overload (for Fan/Pump): 0.37kW
Low overload Icont: 2.4A
High overload (for Machines): 0.37kW
High overload Icont: 2.4A
Brake chopper: no
1 phase input: yes
3 phases input: no


COMP230-P75-20

Centraline Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

208..240V, 1 phase
Voltage: 230V
Low overload (for Fan/Pump): 0.75kW
Low overload Icont: 3.7A
High overload (for Machines): 0.75kW
High overload Icont: 3.7A
Brake chopper: no
1 phase input: yes
3 phases input: no


COMP400-1P1-20

Centraline Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

380..480V, 3 phases
Voltage: 400V
Low overload (for Fan/Pump): 1.1kW
Low overload Icont: 3.3A
High overload (for Machines): 1.1kW
High overload Icont: 3.3A
Brake chopper: no
1 phase input: no
3 phases input: yes


COMP400-1P5-20

Centraline Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

380..480V, 3 phases
Voltage: 400V
Low overload (for Fan/Pump): 1.5kW
Low overload Icont: 4.3A
High overload (for Machines): 1.5kW
High overload Icont: 4.3A
Brake chopper: integrated
1 phase input: no
3 phases input: yes


COMP400-2P2-20

Centraline Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

380..480V, 3 phases
Voltage: 400V
Low overload (for Fan/Pump): 2.2kW
Low overload Icont: 5.6A
High overload (for Machines): 2.2kW
High overload Icont: 5.6A
Brake chopper: integrated
1 phase input: no
3 phases input: yes


COMP400-3P0-20

Centraline Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

380..480V, 3 phases
Voltage: 400V
Low overload (for Fan/Pump): 3kW
Low overload Icont: 7.6A
High overload (for Machines): 3kW
High overload Icont: 7.6A
Brake chopper: integrated
1 phase input: no
3 phases input: yes


COMP400-4P0-20

Centraline Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

380..480V, 3 phases
Voltage: 400V
Low overload (for Fan/Pump): 4kW
Low overload Icont: 9A
High overload (for Machines): 4kW
High overload Icont: 9A
Brake chopper: integrated
1 phase input: no
3 phases input: yes


COMP400-5P5-20

Centraline Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

380..480V, 3 phases
Voltage: 400V
Low overload (for Fan/Pump): 5.5kW
Low overload Icont: 12A
High overload (for Machines): 5.5kW
High overload Icont: 12A
Brake chopper: integrated
1 phase input: no
3 phases input: yes


COMP400-P55-20

Centraline Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

380..480V, 3 phases
Voltage: 400V
Low overload (for Fan/Pump): 0.55kW
Low overload Icont: 1.9A
High overload (for Machines): 0.55kW
High overload Icont: 1.9A
Brake chopper: no
1 phase input: no
3 phases input: yes


COMP400-P75-20

Centraline Inverters 0,37..5,5kW, IP20, SmartDrive Compact

Variable frequency drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
SmartDrive Compact is a compact size micro inverter with easy operation and commissioning. The product offers good possibilities to be used with various applications with high functionality software and 1 rating which can be used in both variable torque (HVAC applications) and constant torque (machines in industrial or process installations).
Features: Start up wizard
Integrated RFI-filters
Flexible side by side mounting with screws or DIN-rail as standard
Compact size
Single rating suitable for both pump and fan or machine applications
Maximum ambient temperature 50 oC; (40 oC for COMP230-2P2-20 and COMP400-5P5-20)
Easy to use single software package with high functionality
Parameter upload/download even without powering the inverter with COMP-LOADER accessory
Configurable Inputs and Outputs
Inputs/Outputs: 2 analog inputs (1 voltage + 1 current), 6 digital inputs, 3 digital outputs (2 relays + 1 open collector), 1 analog output (mA) and Modbus RTU
Series: SmartDrive Compact
RFI-filter: integrated
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (category C2), C-Tick
Safety: EN61800-5, CE, UL, cUL
Protection class: IP20
http://inverter.ecc.emea.honeywell.com

380..480V, 3 phases
Voltage: 400V
Low overload (for Fan/Pump): 0.75kW
Low overload Icont: 2.4A
High overload (for Machines): 0.75kW
High overload Icont: 2.4A
Brake chopper: no
1 phase input: no
3 phases input: yes


CRT12

Centraline Transformer

Protection class: IP00
Input voltage: 220/230 V selectable, 50Hz
Output voltage: 24Vac
With mains fuse. VDE0551 mark.


Model: 288 VA


CRT2

Centraline Transformer

Protection class: IP00
Input voltage: 220/230 V selectable, 50Hz
Output voltage: 24Vac
With mains fuse. VDE0551 mark.


Model: 48 VA


CRT6

Centraline Transformer

Protection class: IP00
Input voltage: 220/230 V selectable, 50Hz
Output voltage: 24Vac
With mains fuse. VDE0551 mark.


Model: 144 VA


CRT6-12

Centraline Transformer, 2 secondary windings

Protection class: IP00
Input voltage: 230 V, 50Hz
Output voltage: 2 x 24Vac, separated
With mains fuse. VDE0551 mark.


Model: 150/250 VA


CRT6-6

Centraline Transformer, 2 secondary windings

Protection class: IP00
Input voltage: 230 V, 50Hz
Output voltage: 2 x 24Vac, separated
With mains fuse. VDE0551 mark.


Model: 144/144 VA


DCPSU-24-1.3

Centraline DC Power Supply

Single phase switched power supply 24 Vdc
Output short circuit protection
DIN rail mounting
2 x 24 V push in terminals
Voltage adjustment


Product description: DC Power Supply 1,3A


DCPSU-24-2.5

Centraline DC Power Supply

Single phase switched power supply 24 Vdc
Output short circuit protection
DIN rail mounting
2 x 24 V push in terminals
Voltage adjustment


Product description: DC Power Supply 2,5A


DCPSU-24-4

Centraline DC Power Supply

Single phase switched power supply 24 Vdc
Output short circuit protection
DIN rail mounting
2 x 24 V push in terminals
Voltage adjustment


Product description: DC Power Supply 4A


DPS1000

Centraline Differential pressure switch for air (DPS)

Filter monitor or flow switch for air, non-combustible, non aggressive gases in air conditioning and ventilating installations.
Kind of pressure: overpressure, relative
Pressure connection: plastic connection piece for 5 mm (internal) hose
Electrical connection: AMP connector 6,3x0,8 (DIN 46244) or screw terminals
Protection class: IP54
Sensing element material: ABS + Silicon
Media temp.: -20...85C
Ambient temperature: -20...85C
Switch function/capacity: SPDT switch 240 Vac; 1,5 A (0.4)A
Certificates: CE0085AR0013 according EC Gas Appliance Directive EU/2009/142/EG and DIN EN 1854
Accessories supplied with pressure switch: 2 m silicon hose, 2 connection pieces with mounting screws, 2 self tapping screws for mounting on housing, 3 screw terminals for electrical connection.
Max. pressure: 10kPa


Pressure adjustment range: 200...1000Pa
Switching differential: 1mbar


DPS200

Centraline Differential pressure switch for air (DPS)

Filter monitor or flow switch for air, non-combustible, non aggressive gases in air conditioning and ventilating installations.
Kind of pressure: overpressure, relative
Pressure connection: plastic connection piece for 5 mm (internal) hose
Electrical connection: AMP connector 6,3x0,8 (DIN 46244) or screw terminals
Protection class: IP54
Sensing element material: ABS + Silicon
Media temp.: -20...85C
Ambient temperature: -20...85C
Switch function/capacity: SPDT switch 240 Vac; 1,5 A (0.4)A
Certificates: CE0085AR0013 according EC Gas Appliance Directive EU/2009/142/EG and DIN EN 1854
Accessories supplied with pressure switch: 2 m silicon hose, 2 connection pieces with mounting screws, 2 self tapping screws for mounting on housing, 3 screw terminals for electrical connection.
Max. pressure: 10kPa


Pressure adjustment range: 20...200Pa
Switching differential: 0.1mbar


DPS2500

Centraline Differential pressure switch for air (DPS)

Filter monitor or flow switch for air, non-combustible, non aggressive gases in air conditioning and ventilating installations.
Kind of pressure: overpressure, relative
Pressure connection: plastic connection piece for 5 mm (internal) hose
Electrical connection: AMP connector 6,3x0,8 (DIN 46244) or screw terminals
Protection class: IP54
Sensing element material: ABS + Silicon
Media temp.: -20...85C
Ambient temperature: -20...85C
Switch function/capacity: SPDT switch 240 Vac; 1,5 A (0.4)A
Certificates: CE0085AR0013 according EC Gas Appliance Directive EU/2009/142/EG and DIN EN 1854
Accessories supplied with pressure switch: 2 m silicon hose, 2 connection pieces with mounting screws, 2 self tapping screws for mounting on housing, 3 screw terminals for electrical connection.
Max. pressure: 10kPa


Pressure adjustment range: 500...2500Pa
Switching differential: 1.5mbar


DPS400

Centraline Differential pressure switch for air (DPS)

Filter monitor or flow switch for air, non-combustible, non aggressive gases in air conditioning and ventilating installations.
Kind of pressure: overpressure, relative
Pressure connection: plastic connection piece for 5 mm (internal) hose
Electrical connection: AMP connector 6,3x0,8 (DIN 46244) or screw terminals
Protection class: IP54
Sensing element material: ABS + Silicon
Media temp.: -20...85C
Ambient temperature: -20...85C
Switch function/capacity: SPDT switch 240 Vac; 1,5 A (0.4)A
Certificates: CE0085AR0013 according EC Gas Appliance Directive EU/2009/142/EG and DIN EN 1854
Accessories supplied with pressure switch: 2 m silicon hose, 2 connection pieces with mounting screws, 2 self tapping screws for mounting on housing, 3 screw terminals for electrical connection.
Max. pressure: 10kPa


Pressure adjustment range: 40...400Pa
Switching differential: 0.2mbar


DPS500

Centraline Differential pressure switch for air (DPS)

Filter monitor or flow switch for air, non-combustible, non aggressive gases in air conditioning and ventilating installations.
Kind of pressure: overpressure, relative
Pressure connection: plastic connection piece for 5 mm (internal) hose
Electrical connection: AMP connector 6,3x0,8 (DIN 46244) or screw terminals
Protection class: IP54
Sensing element material: ABS + Silicon
Media temp.: -20...85C
Ambient temperature: -20...85C
Switch function/capacity: SPDT switch 240 Vac; 1,5 A (0.4)A
Certificates: CE0085AR0013 according EC Gas Appliance Directive EU/2009/142/EG and DIN EN 1854
Accessories supplied with pressure switch: 2 m silicon hose, 2 connection pieces with mounting screws, 2 self tapping screws for mounting on housing, 3 screw terminals for electrical connection.
Max. pressure: 10kPa


Pressure adjustment range: 50...500Pa
Switching differential: 0.2mbar


DPSK

Centraline Differential pressure transmitter for air (DPTE)
Accessories

Duct Kit, including 2m silicone-hose and 2 joining pipes DPSJ with screws



DPSL

Centraline Differential pressure transmitter for air (DPTE)
Accessories

Mounting brackets L-shaped



DPTE100

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V/4 - 20 mA, analog output, supply voltage 18...30 Vac/dc, 50/60 Hz
Pressure range: 0...100/250Pa
Max. pressure: 20kPa


DPTE1000

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V/4 - 20 mA, analog output, supply voltage 18...30 Vac/dc, 50/60 Hz
Pressure range: 0...1000/2500Pa
Max. pressure: 40kPa


DPTE1000D

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V / 4 - 20 mA analog output, supply voltage 18...30 Vac/dc, 50/60 Hz; WITH LED Display
Pressure range: 0...1000/2500Pa
Max. pressure: 40kPa


DPTE1000S

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V/4 - 20 mA, analog output, supply voltage 18...30 Vac/dc, 50/60 Hz
Pressure range: -1000...1000Pa
Max. pressure: 20kPa


DPTE1000SD

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V / 4 - 20 mA analog output, supply voltage 18...30 Vac/dc, 50/60 Hz; WITH LED Display
Pressure range: -1000...1000Pa
Max. pressure: 20kPa


DPTE1002

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

2-wire models, analog output 4 - 20 mA, supply voltage 16 ... 32 Vdc
Pressure range: 0...1000/2500Pa
Max. pressure: 40kPa


DPTE100D

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V / 4 - 20 mA analog output, supply voltage 18...30 Vac/dc, 50/60 Hz; WITH LED Display
Pressure range: 0...100/250Pa
Max. pressure: 20kPa


DPTE100S

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V/4 - 20 mA, analog output, supply voltage 18...30 Vac/dc, 50/60 Hz
Pressure range: -100...100Pa
Max. pressure: 20kPa


DPTE100SD

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V / 4 - 20 mA analog output, supply voltage 18...30 Vac/dc, 50/60 Hz; WITH LED Display
Pressure range: -100...100Pa
Max. pressure: 20kPa


DPTE102

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

2-wire models, analog output 4 - 20 mA, supply voltage 16 ... 32 Vdc
Pressure range: 0...100/250Pa
Max. pressure: 20kPa


DPTE102S

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

2-wire models, analog output 4 - 20 mA, supply voltage 16 ... 32 Vdc
Pressure range: -100...100Pa
Max. pressure: 20kPa


DPTE250

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V/4 - 20 mA, analog output, supply voltage 18...30 Vac/dc, 50/60 Hz
Pressure range: 0...250/500Pa
Max. pressure: 20kPa


DPTE250D

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V / 4 - 20 mA analog output, supply voltage 18...30 Vac/dc, 50/60 Hz; WITH LED Display
Pressure range: 0...250/500Pa
Max. pressure: 20kPa


DPTE252

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

2-wire models, analog output 4 - 20 mA, supply voltage 16 ... 32 Vdc
Pressure range: 0...250/500Pa
Max. pressure: 20kPa


DPTE500

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V/4 - 20 mA, analog output, supply voltage 18...30 Vac/dc, 50/60 Hz
Pressure range: 0...500/1000Pa
Max. pressure: 20kPa


DPTE5000

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V/4 - 20 mA, analog output, supply voltage 18...30 Vac/dc, 50/60 Hz
Pressure range: 0...5000/10000Pa
Max. pressure: 60kPa


DPTE5000D

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V / 4 - 20 mA analog output, supply voltage 18...30 Vac/dc, 50/60 Hz; WITH LED Display
Pressure range: 0...5000/10000Pa
Max. pressure: 60kPa


DPTE5002

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

2-wire models, analog output 4 - 20 mA, supply voltage 16 ... 32 Vdc
Pressure range: 0...5000/10000Pa
Max. pressure: 60kPa


DPTE500D

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V / 4 - 20 mA analog output, supply voltage 18...30 Vac/dc, 50/60 Hz; WITH LED Display
Pressure range: 0...500/1000Pa
Max. pressure: 20kPa


DPTE500S

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V/4 - 20 mA, analog output, supply voltage 18...30 Vac/dc, 50/60 Hz
Pressure range: -500...500Pa
Max. pressure: 20kPa


DPTE500SD

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V / 4 - 20 mA analog output, supply voltage 18...30 Vac/dc, 50/60 Hz; WITH LED Display
Pressure range: -500...500Pa
Max. pressure: 20kPa


DPTE502

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

2-wire models, analog output 4 - 20 mA, supply voltage 16 ... 32 Vdc
Pressure range: 0...500/1000Pa
Max. pressure: 20kPa


DPTE50S

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V/4 - 20 mA, analog output, supply voltage 18...30 Vac/dc, 50/60 Hz
Pressure range: -50...50Pa
Max. pressure: 20kPa


DPTE50SD

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

3-wire models, selectable 0 - 10 V / 4 - 20 mA analog output, supply voltage 18...30 Vac/dc, 50/60 Hz; WITH LED Display
Pressure range: -50...50Pa
Max. pressure: 20kPa


DPTE52S

Centraline Differential pressure transmitter for air (DPTE)

Differential pressure transmitter for air-conditioning/ventilation.
Air-conditioning and ventilation systems, Building automation, Environmental protection, Fan and ventilation control, Valve and shutter control, Filter and fan monitoring
Kind of pressure: differential pressure, relative
Pressure connection: 6mm hose pipe
Electrical connection: M20x1,5
Protection class: IP54
Housing material: ABS and POM
Sensing method: piezoresistive
Sensing element material: ABS + POM
Media temp.: 0...50C
Medium: gaseous
Ambient temperature: 0...50C
Duct Kit DPSK included in delivery of single package.
Adjustable by jumper to the next higher pressure range.
Factory settings: see column "pressure range". Full scale pressure range see data sheet

2-wire models, analog output 4 - 20 mA, supply voltage 16 ... 32 Vdc
Pressure range: -50...50Pa
Max. pressure: 20kPa


DR100GFLA

Centraline Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN6
Reduced delta P: 40kPa

Flanges
DN size: 100mm
Kvs value: 160
Max. delta P: 100kPa
Torque for max. delta P: 40Nm
Torque for reduced delta P: 30Nm
Port connection: flanges DIN2531


DR125GFLA

Centraline Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN6
Reduced delta P: 40kPa

Flanges
DN size: 125mm
Kvs value: 250
Max. delta P: 70kPa
Torque for max. delta P: 40Nm
Torque for reduced delta P: 30Nm
Port connection: flanges DIN2531


DR15-2GMLA

Centraline Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN6
Reduced delta P: 40kPa

Internal threads
DN size: 15mm
Kvs value: 2.5
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: internal threads


DR150GFLA

Centraline Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN6
Reduced delta P: 40kPa

Flanges
DN size: 150mm
Kvs value: 630
Max. delta P: 50kPa
Torque for max. delta P: 40Nm
Torque for reduced delta P: 40Nm
Port connection: flanges DIN2531


DR15GMLA

Centraline Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN6
Reduced delta P: 40kPa

Internal threads
DN size: 15mm
Kvs value: 4
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: internal threads


DR200GFLA

Centraline Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN6
Reduced delta P: 40kPa

Flanges
DN size: 200mm
Kvs value: 1600
Max. delta P: 50kPa
Torque for max. delta P: 40Nm
Torque for reduced delta P: 40Nm
Port connection: flanges DIN2531


DR200GFLA1

Centraline Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN6
Reduced delta P: 40kPa

Flanges
DN size: 200mm
Kvs value: 1000
Max. delta P: 50kPa
Torque for max. delta P: 40Nm
Torque for reduced delta P: 40Nm
Port connection: flanges DIN2531


DR20GFLA

Centraline Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN6
Reduced delta P: 40kPa

Flanges
DN size: 20mm
Kvs value: 6.3
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: flanges DIN2531


DR20GMLA

Centraline Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN6
Reduced delta P: 40kPa

Internal threads
DN size: 20mm
Kvs value: 6.3
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: internal threads


DR25GFLA

Centraline Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN6
Reduced delta P: 40kPa

Flanges
DN size: 25mm
Kvs value: 10
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: flanges DIN2531


DR25GMLA

Centraline Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN6
Reduced delta P: 40kPa

Internal threads
DN size: 25mm
Kvs value: 10
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: internal threads


DR32GFLA

Centraline Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN6
Reduced delta P: 40kPa

Flanges
DN size: 32mm
Kvs value: 16
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: flanges DIN2531


DR32GMLA

Centraline Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN6
Reduced delta P: 40kPa

Internal threads
DN size: 32mm
Kvs value: 16
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: internal threads


DR40GFLA

Centraline Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN6
Reduced delta P: 40kPa

Flanges
DN size: 40mm
Kvs value: 25
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: flanges DIN2531


DR40GMLA

Centraline Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN6
Reduced delta P: 40kPa

Internal threads
DN size: 40mm
Kvs value: 25
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: internal threads


DR50GFLA

Centraline Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN6
Reduced delta P: 40kPa

Flanges
DN size: 50mm
Kvs value: 40
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: flanges DIN2531


DR65GFLA

Centraline Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN6
Reduced delta P: 40kPa

Flanges
DN size: 65mm
Kvs value: 63
Max. delta P: 100kPa
Torque for max. delta P: 20Nm
Torque for reduced delta P: 20Nm
Port connection: flanges DIN2531


DR80GFLA

Centraline Three-way rotary valve PN6

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRG
Valve type: 3-way rotary mixing
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN6
Reduced delta P: 40kPa

Flanges
DN size: 80mm
Kvs value: 100
Max. delta P: 100kPa
Torque for max. delta P: 30Nm
Torque for reduced delta P: 20Nm
Port connection: flanges DIN2531


DRA-02L

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Display panel kits
Product description: NXL door installation set for display panel, 2m cable
HVAC400: no
NXL HVAC: yes
NXS: no
HVAC232/402: no


DRA-04B

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Display panel kits
Product description: NXS door installation set for display panel, 4m cable
HVAC400: no
NXL HVAC: no
NXS: yes
HVAC232/402: no


DRA-04L

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Display panel kits
Product description: NXL door installation set for display panel, 4m cable
HVAC400: no
NXL HVAC: yes
NXS: no
HVAC232/402: no


DRA02B

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Display panel kits
Product description: NXS door installation set for display panel, 2m cable
HVAC400: no
NXL HVAC: no
NXS: yes
HVAC232/402: no


DRU25-10

Centraline Three-way rotary valve PN10

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRU
Valve type: 3-way rotary mixing, bypass
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN10
Port connection: external threads
Max. delta P: 100kPa
Torque for max. delta P: 20Nm

Universal Rotary Valve
DN size: 25mm
Kvs value: 10


DRU25-16

Centraline Three-way rotary valve PN10

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRU
Valve type: 3-way rotary mixing, bypass
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN10
Port connection: external threads
Max. delta P: 100kPa
Torque for max. delta P: 20Nm

Universal Rotary Valve
DN size: 25mm
Kvs value: 16


DRU25-2.5

Centraline Three-way rotary valve PN10

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRU
Valve type: 3-way rotary mixing, bypass
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN10
Port connection: external threads
Max. delta P: 100kPa
Torque for max. delta P: 20Nm

Universal Rotary Valve
DN size: 25mm
Kvs value: 2.5


DRU25-4.0

Centraline Three-way rotary valve PN10

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRU
Valve type: 3-way rotary mixing, bypass
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN10
Port connection: external threads
Max. delta P: 100kPa
Torque for max. delta P: 20Nm

Universal Rotary Valve
DN size: 25mm
Kvs value: 4


DRU25-6.3

Centraline Three-way rotary valve PN10

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRU
Valve type: 3-way rotary mixing, bypass
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN10
Port connection: external threads
Max. delta P: 100kPa
Torque for max. delta P: 20Nm

Universal Rotary Valve
DN size: 25mm
Kvs value: 6.3


DRU32-10

Centraline Three-way rotary valve PN10

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRU
Valve type: 3-way rotary mixing, bypass
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN10
Port connection: external threads
Max. delta P: 100kPa
Torque for max. delta P: 20Nm

Universal Rotary Valve
DN size: 32mm
Kvs value: 10


DRU32-16

Centraline Three-way rotary valve PN10

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRU
Valve type: 3-way rotary mixing, bypass
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN10
Port connection: external threads
Max. delta P: 100kPa
Torque for max. delta P: 20Nm

Universal Rotary Valve
DN size: 32mm
Kvs value: 16


DRU32-25

Centraline Three-way rotary valve PN10

For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series: DRU
Valve type: 3-way rotary mixing, bypass
Medium type: water
Materials: body cast iron, inner parts chrome plated
Packing: double O-ring sealing
Angle of rotation: 90o
Media temp.: 2...130C
Pressure rating: PN10
Port connection: external threads
Max. delta P: 100kPa
Torque for max. delta P: 20Nm

Universal Rotary Valve
DN size: 32mm
Kvs value: 25


DTS92A1011

Centraline evohome, colour screen multi-zone controller with remote access
evohome components

Digital Room sensor/setpoint adjustment unit



DTS92E1020

Centraline evohome, colour screen multi-zone controller with remote access
evohome components

Digital Room sensor/setpoint adjustment unit with ECO



E53205C-HW

Centraline E53205 - Heat cost allocator with AMR and 2-sensor Walk-By technology

The E53205 is an electronic device for the allocation of heating costs based on the heat dispersion of radiators. With regard to metering technology, the E53205 model is fully compatible with the previous E43205 version. Its physical features and dimensions are also identical to the E43205 version. The difference lies in its improved and extended wireless properties, both in S mode (Walk-by and AMR) and C mode (Walk-by and OMS). Communication with current software versions of the HMA Suite (V 2.2 or later) and of ACT46 (V 1.6 or later) is available without limitation. The E53205 electronic heat cost allocator is intended for decentralised use. Values are measured by two temperature sensors (radiator and ambient). During operation, the device determines the actual difference between the temperature of the room and of the radiator. These measured values are then used as the basis for the consumption calculation. The main area of application is in centralised heating systems where energy for heating is used individually by various consumers.
Typical applications include:
Residential complexes
Office buildings and buildings used by public bodies
Thanks to a wide range of mounting kits, the electronic meter can be fixed to almost any kind of radiator, including ribbed or tubular radiators, convector heaters, and so on, regardless of whether it is a new installation or a replacement.
Compliant with Directive ETS 300 220-1
Certified in accordance with EN 834
Battery powered (battery included), 10-year life span


Product description: Heat cost allocator with AMR and 2-sensor Walk-By technology - C Mode


E53205S-HW

Centraline E53205 - Heat cost allocator with AMR and 2-sensor Walk-By technology

The E53205 is an electronic device for the allocation of heating costs based on the heat dispersion of radiators. With regard to metering technology, the E53205 model is fully compatible with the previous E43205 version. Its physical features and dimensions are also identical to the E43205 version. The difference lies in its improved and extended wireless properties, both in S mode (Walk-by and AMR) and C mode (Walk-by and OMS). Communication with current software versions of the HMA Suite (V 2.2 or later) and of ACT46 (V 1.6 or later) is available without limitation. The E53205 electronic heat cost allocator is intended for decentralised use. Values are measured by two temperature sensors (radiator and ambient). During operation, the device determines the actual difference between the temperature of the room and of the radiator. These measured values are then used as the basis for the consumption calculation. The main area of application is in centralised heating systems where energy for heating is used individually by various consumers.
Typical applications include:
Residential complexes
Office buildings and buildings used by public bodies
Thanks to a wide range of mounting kits, the electronic meter can be fixed to almost any kind of radiator, including ribbed or tubular radiators, convector heaters, and so on, regardless of whether it is a new installation or a replacement.
Compliant with Directive ETS 300 220-1
Certified in accordance with EN 834
Battery powered (battery included), 10-year life span


Product description: Heat cost allocator with AMR and 2-sensor Walk-By technology - S Mode


EEM230-D-M

Centraline Electrical Energy Meters, 1 phase, 32A, LCD, EEM230-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage, active and reactive power.
Single phase energy meter, 230VAC 50 Hz
Direct measurement up to 32 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy
Resettable value of partial energy
Display of instantaneous power
Reactive power available through interface
Display of voltage
Display of current
Clear fault indication


Interface: M-Bus
Certificates: no


EEM230-D-M-MID

Centraline Electrical Energy Meters, 1 phase, 32A, LCD, EEM230-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage, active and reactive power.
Single phase energy meter, 230VAC 50 Hz
Direct measurement up to 32 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy
Resettable value of partial energy
Display of instantaneous power
Reactive power available through interface
Display of voltage
Display of current
Clear fault indication


Interface: M-Bus
Certificates: MID


EEM230-D-MO

Centraline Electrical Energy Meters, 1 phase, 32A, LCD, EEM230-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage, active and reactive power.
Single phase energy meter, 230VAC 50 Hz
Direct measurement up to 32 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy
Resettable value of partial energy
Display of instantaneous power
Reactive power available through interface
Display of voltage
Display of current
Clear fault indication


Interface: ModBus RTU
Certificates: no


EEM230-D-MO-MID

Centraline Electrical Energy Meters, 1 phase, 32A, LCD, EEM230-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage, active and reactive power.
Single phase energy meter, 230VAC 50 Hz
Direct measurement up to 32 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy
Resettable value of partial energy
Display of instantaneous power
Reactive power available through interface
Display of voltage
Display of current
Clear fault indication


Interface: ModBus RTU
Certificates: MID


EEM230-D-P

Centraline Electrical Energy Meters, 1 phase, 32A, LCD, EEM230-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage, active and reactive power.
Single phase energy meter, 230VAC 50 Hz
Direct measurement up to 32 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy
Resettable value of partial energy
Display of instantaneous power
Reactive power available through interface
Display of voltage
Display of current
Clear fault indication


Interface: pulse
Certificates: no


EEM230-D-P-MID

Centraline Electrical Energy Meters, 1 phase, 32A, LCD, EEM230-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage, active and reactive power.
Single phase energy meter, 230VAC 50 Hz
Direct measurement up to 32 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy
Resettable value of partial energy
Display of instantaneous power
Reactive power available through interface
Display of voltage
Display of current
Clear fault indication


Interface: pulse
Certificates: MID


EEM230-E-P

Centraline Electrical Energy Meters, 1 phase, 32A, LCD, Economic, EEM230-E

Energy meter with LCD display and integrated S0 interface. The S0 interface is a hardware interface for the transmission of measured values in building automation.
Single phase energy meter, 230VAC 50 Hz
Direct measurement up to 32 A
7-digit LC-Display
Lead seal possible with cap as accessory
Precision class 1 according to IEC62053-21
S0 output according to IEC62053-31
Clear fault indication
Interface: pulse


EEM230-SEALCAP

Centraline Electrical Energy Meters, 1 phase, 32A, LCD, EEM230-D


20 sealcaps (for 10 energy meters)



EEM400-D-M

Centraline Electrical Energy Meters, 3 phases, 65A, 2 Tariff, LCD, EEM400-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Direct measurement up to 65 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
2 tariff measuring
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: M-Bus
Certificates: no


EEM400-D-M-MID

Centraline Electrical Energy Meters, 3 phases, 65A, 2 Tariff, LCD, EEM400-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Direct measurement up to 65 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
2 tariff measuring
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: M-Bus
Certificates: MID


EEM400-D-MO

Centraline Electrical Energy Meters, 3 phases, 65A, 2 Tariff, LCD, EEM400-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Direct measurement up to 65 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
2 tariff measuring
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: ModBus RTU
Certificates: no


EEM400-D-MO-MID

Centraline Electrical Energy Meters, 3 phases, 65A, 2 Tariff, LCD, EEM400-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Direct measurement up to 65 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
2 tariff measuring
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: ModBus RTU
Certificates: MID


EEM400-D-P

Centraline Electrical Energy Meters, 3 phases, 65A, 2 Tariff, LCD, EEM400-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Direct measurement up to 65 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
2 tariff measuring
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: pulse
Certificates: no


EEM400-D-P-MID

Centraline Electrical Energy Meters, 3 phases, 65A, 2 Tariff, LCD, EEM400-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Direct measurement up to 65 A
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
2 tariff measuring
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: pulse
Certificates: MID


EEM400-SEALCAP

Centraline Electrical Energy Meters, 3 phases, 65A, 2 Tariff, LCD, EEM400-D


20 sealcaps (for 5 energy meters)



EEM400C-D-M

Centraline Electrical Energy Meters, 3 phases for current transformer 5A, LCD, EEM400C-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Measurement up to 1.500 A over external current transformer
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
CT ratio is blocked through a wire bridge
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: M-Bus
Certificates: no


EEM400C-D-M-MID

Centraline Electrical Energy Meters, 3 phases for current transformer 5A, LCD, EEM400C-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Measurement up to 1.500 A over external current transformer
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
CT ratio is blocked through a wire bridge
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: M-Bus
Certificates: MID


EEM400C-D-MO

Centraline Electrical Energy Meters, 3 phases for current transformer 5A, LCD, EEM400C-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Measurement up to 1.500 A over external current transformer
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
CT ratio is blocked through a wire bridge
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: ModBus RTU
Certificates: no


EEM400C-D-MO-MID

Centraline Electrical Energy Meters, 3 phases for current transformer 5A, LCD, EEM400C-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Measurement up to 1.500 A over external current transformer
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
CT ratio is blocked through a wire bridge
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: ModBus RTU
Certificates: MID


EEM400C-D-P

Centraline Electrical Energy Meters, 3 phases for current transformer 5A, LCD, EEM400C-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Measurement up to 1.500 A over external current transformer
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
CT ratio is blocked through a wire bridge
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: pulse
Certificates: no


EEM400C-D-P-MID

Centraline Electrical Energy Meters, 3 phases for current transformer 5A, LCD, EEM400C-D

Electrical energy meter with direct reading of all relevant data, such as energy (total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases.
3-phase energy meter, 3 x 230/400 VAC 50 Hz
Measurement up to 1.500 A over external current transformer
Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
7-digits display, clear read-out with 6 mm tall figures
Backlighted LCD
Metering of total and partial consumed energy, partial resettable
CT ratio is blocked through a wire bridge
Display of instantaneous power for each phase and all phases
Display of voltage of each phase
Display of current
Reactive power for every and/or all phases available through interface
Energy value readable without power supply
Clear fault indication


Interface: pulse
Certificates: MID


ENC-Slot-MI1-3

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Input/output expander cards
Product description: Required external cover to fix option boards on HVAC232/402 frame size 1..3 for devices up to 5,5 kW
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


ENC-Slot-MI4-5

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Input/output expander cards
Product description: Required internal moulding to fix option boards on HVAC232/402 frame size 4..5 for devices bigger than 5,5 kW
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


EVA1-DANFOSS

Centraline RF Electronic radiator controller HR92
Valve adapters

Danfoss RAV/RAVL/RA



EW1000AZ1101

Centraline EW100 Series Singlejet Water Meters DN15...20

Honeywell EW100 Series singlejet water meters are used for flow measurement of cold or warm water in residential potable water systems. They are available in sizes DN15 and DN20 and have a roller counter with the option to upgrade to RF output. EW1000 watermeters are suitable for cold water up to 30C. EW1001 watermeters are suitable for warm water up to 90C.
Metering of cold or warm potable water.
Approvals: MID
Features: Compact design
Rotatable counter
Retrofittable RF modules
Product description: EW100 Series water meters with RF module are only suitable for integration into Honeywell heat cost allocator systems.
Measuring method: single jet
Display functions: Roller counter, 8-digit
Max. operating pressure: 16bar
Interface: none (retrofittable)

EW100 Series for cold water
Medium: cold potable water
Permanent flow: 1.5m3/h
Media temp.: 1...30C
DN size: 15mm
Length: 80mm
Connection: G 3/4


EW1000AZ1201

Centraline EW100 Series Singlejet Water Meters DN15...20

Honeywell EW100 Series singlejet water meters are used for flow measurement of cold or warm water in residential potable water systems. They are available in sizes DN15 and DN20 and have a roller counter with the option to upgrade to RF output. EW1000 watermeters are suitable for cold water up to 30C. EW1001 watermeters are suitable for warm water up to 90C.
Metering of cold or warm potable water.
Approvals: MID
Features: Compact design
Rotatable counter
Retrofittable RF modules
Product description: EW100 Series water meters with RF module are only suitable for integration into Honeywell heat cost allocator systems.
Measuring method: single jet
Display functions: Roller counter, 8-digit
Max. operating pressure: 16bar
Interface: none (retrofittable)

EW100 Series for cold water
Medium: cold potable water
Permanent flow: 1.5m3/h
Media temp.: 1...30C
DN size: 15mm
Length: 110mm
Connection: G 3/4


EW1000AZ2001

Centraline EW100 Series Singlejet Water Meters DN15...20

Honeywell EW100 Series singlejet water meters are used for flow measurement of cold or warm water in residential potable water systems. They are available in sizes DN15 and DN20 and have a roller counter with the option to upgrade to RF output. EW1000 watermeters are suitable for cold water up to 30C. EW1001 watermeters are suitable for warm water up to 90C.
Metering of cold or warm potable water.
Approvals: MID
Features: Compact design
Rotatable counter
Retrofittable RF modules
Product description: EW100 Series water meters with RF module are only suitable for integration into Honeywell heat cost allocator systems.
Measuring method: single jet
Display functions: Roller counter, 8-digit
Max. operating pressure: 16bar
Interface: none (retrofittable)

EW100 Series for cold water
Medium: cold potable water
Permanent flow: 2.5m3/h
Media temp.: 1...30C
DN size: 20mm
Length: 130mm
Connection: G 1


EW1001AZ1101

Centraline EW100 Series Singlejet Water Meters DN15...20

Honeywell EW100 Series singlejet water meters are used for flow measurement of cold or warm water in residential potable water systems. They are available in sizes DN15 and DN20 and have a roller counter with the option to upgrade to RF output. EW1000 watermeters are suitable for cold water up to 30C. EW1001 watermeters are suitable for warm water up to 90C.
Metering of cold or warm potable water.
Approvals: MID
Features: Compact design
Rotatable counter
Retrofittable RF modules
Product description: EW100 Series water meters with RF module are only suitable for integration into Honeywell heat cost allocator systems.
Measuring method: single jet
Display functions: Roller counter, 8-digit
Max. operating pressure: 16bar
Interface: none (retrofittable)

EW100 Series for warm water
Medium: warm potable water
Permanent flow: 1.5m3/h
Media temp.: 1...90C
DN size: 15mm
Length: 80mm
Connection: G 3/4


EW1001AZ1201

Centraline EW100 Series Singlejet Water Meters DN15...20

Honeywell EW100 Series singlejet water meters are used for flow measurement of cold or warm water in residential potable water systems. They are available in sizes DN15 and DN20 and have a roller counter with the option to upgrade to RF output. EW1000 watermeters are suitable for cold water up to 30C. EW1001 watermeters are suitable for warm water up to 90C.
Metering of cold or warm potable water.
Approvals: MID
Features: Compact design
Rotatable counter
Retrofittable RF modules
Product description: EW100 Series water meters with RF module are only suitable for integration into Honeywell heat cost allocator systems.
Measuring method: single jet
Display functions: Roller counter, 8-digit
Max. operating pressure: 16bar
Interface: none (retrofittable)

EW100 Series for warm water
Medium: warm potable water
Permanent flow: 1.5m3/h
Media temp.: 1...90C
DN size: 15mm
Length: 110mm
Connection: G 3/4


EW1001AZ2001

Centraline EW100 Series Singlejet Water Meters DN15...20

Honeywell EW100 Series singlejet water meters are used for flow measurement of cold or warm water in residential potable water systems. They are available in sizes DN15 and DN20 and have a roller counter with the option to upgrade to RF output. EW1000 watermeters are suitable for cold water up to 30C. EW1001 watermeters are suitable for warm water up to 90C.
Metering of cold or warm potable water.
Approvals: MID
Features: Compact design
Rotatable counter
Retrofittable RF modules
Product description: EW100 Series water meters with RF module are only suitable for integration into Honeywell heat cost allocator systems.
Measuring method: single jet
Display functions: Roller counter, 8-digit
Max. operating pressure: 16bar
Interface: none (retrofittable)

EW100 Series for warm water
Medium: warm potable water
Permanent flow: 2.5m3/h
Media temp.: 1...90C
DN size: 20mm
Length: 130mm
Connection: G 1


EW1050AP1200

Centraline EW105 Singlejet Pulse out Water Meters DN15...20

Honeywell EW105 Singlejet pulse out water meters are used for flow measurement of cold or warm water in residential potable water systems. They are available in sizes DN15 and DN20 and have a roller counter as well as a pulse cable permanently attached to the housing.
EW1050 water meters are suitable for cold water up to 30C. EW1051 water meters are suitable for warm water up to 90C.
Features: Fully resistant to external magnetic fields
Robust singlejet flow sensor
Pulse output as standard
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: Five digit roller counter
Approvals: MID
Interface: Pulse out
Interface type: Fixed

EW1050 for cold water
DN size: 15mm
Permanent flow: 2.5m3/h
Length: 110mm
Connection: G 3/4
Temperature class: T30


EW1050AP2000

Centraline EW105 Singlejet Pulse out Water Meters DN15...20

Honeywell EW105 Singlejet pulse out water meters are used for flow measurement of cold or warm water in residential potable water systems. They are available in sizes DN15 and DN20 and have a roller counter as well as a pulse cable permanently attached to the housing.
EW1050 water meters are suitable for cold water up to 30C. EW1051 water meters are suitable for warm water up to 90C.
Features: Fully resistant to external magnetic fields
Robust singlejet flow sensor
Pulse output as standard
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: Five digit roller counter
Approvals: MID
Interface: Pulse out
Interface type: Fixed

EW1050 for cold water
DN size: 20mm
Permanent flow: 4m3/h
Length: 130mm
Connection: G 1
Temperature class: T30


EW1051AP1200

Centraline EW105 Singlejet Pulse out Water Meters DN15...20

Honeywell EW105 Singlejet pulse out water meters are used for flow measurement of cold or warm water in residential potable water systems. They are available in sizes DN15 and DN20 and have a roller counter as well as a pulse cable permanently attached to the housing.
EW1050 water meters are suitable for cold water up to 30C. EW1051 water meters are suitable for warm water up to 90C.
Features: Fully resistant to external magnetic fields
Robust singlejet flow sensor
Pulse output as standard
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: Five digit roller counter
Approvals: MID
Interface: Pulse out
Interface type: Fixed

EW1051 for warm water
DN size: 15mm
Permanent flow: 2.5m3/h
Length: 110mm
Connection: G 3/4
Temperature class: T90


EW1051AP2000

Centraline EW105 Singlejet Pulse out Water Meters DN15...20

Honeywell EW105 Singlejet pulse out water meters are used for flow measurement of cold or warm water in residential potable water systems. They are available in sizes DN15 and DN20 and have a roller counter as well as a pulse cable permanently attached to the housing.
EW1050 water meters are suitable for cold water up to 30C. EW1051 water meters are suitable for warm water up to 90C.
Features: Fully resistant to external magnetic fields
Robust singlejet flow sensor
Pulse output as standard
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: Five digit roller counter
Approvals: MID
Interface: Pulse out
Interface type: Fixed

EW1051 for warm water
DN size: 20mm
Permanent flow: 4m3/h
Length: 130mm
Connection: G 1
Temperature class: T90


EW1100AC0600

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1100 for cold water
DN size: 15mm
Permanent flow: 1.6m3/h
Length: 110mm
Connection: G 3/4
Temperature class: T30
Interface: no
Interface type: Retrofittable


EW1100AC1100

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1100 for cold water
DN size: 15mm
Permanent flow: 2.5m3/h
Length: 80mm
Connection: G 3/4
Temperature class: T30
Interface: no
Interface type: Retrofittable


EW1100AC1200

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1100 for cold water
DN size: 15mm
Permanent flow: 2.5m3/h
Length: 110mm
Connection: G 3/4
Temperature class: T30
Interface: no
Interface type: Retrofittable


EW1100AC1400

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1100 for cold water
DN size: 20mm
Permanent flow: 2.5m3/h
Length: 130mm
Connection: G 1
Temperature class: T30
Interface: no
Interface type: Retrofittable


EW1100AC2000

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1100 for cold water
DN size: 20mm
Permanent flow: 4m3/h
Length: 130mm
Connection: G 1
Temperature class: T30
Interface: no
Interface type: Retrofittable


EW1100CC2800

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1100 for cold water
DN size: 25mm
Permanent flow: 6.3m3/h
Length: 260mm
Connection: G 1 1/4
Temperature class: T30
Interface: no
Interface type: Retrofittable


EW1100CC3900

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1100 for cold water
DN size: 32mm
Permanent flow: 10m3/h
Length: 260mm
Connection: G 1 1/2
Temperature class: T30
Interface: no
Interface type: Retrofittable


EW1100CC4600

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1100 for cold water
DN size: 40mm
Permanent flow: 16m3/h
Length: 300mm
Connection: G 2
Temperature class: T30
Interface: no
Interface type: Retrofittable


EW1100CM1200

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1100 for cold water, with M-Bus module fitted
DN size: 15mm
Permanent flow: 2.5m3/h
Length: 110mm
Connection: G 3/4
Temperature class: T30
Interface: M-Bus
Interface type: Retrofittable (factory installed)


EW1100CM2000

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1100 for cold water, with M-Bus module fitted
DN size: 20mm
Permanent flow: 4m3/h
Length: 130mm
Connection: G 1
Temperature class: T30
Interface: M-Bus
Interface type: Retrofittable (factory installed)


EW1100CM2800

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1100 for cold water, with M-Bus module fitted
DN size: 25mm
Permanent flow: 6.3m3/h
Length: 260mm
Connection: G 1 1/4
Temperature class: T30
Interface: M-Bus
Interface type: Retrofittable (factory installed)


EW1100CM3900

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1100 for cold water, with M-Bus module fitted
DN size: 32mm
Permanent flow: 10m3/h
Length: 260mm
Connection: G 1 1/2
Temperature class: T30
Interface: M-Bus
Interface type: Retrofittable (factory installed)


EW1100CM4600

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1100 for cold water, with M-Bus module fitted
DN size: 40mm
Permanent flow: 16m3/h
Length: 300mm
Connection: G 2
Temperature class: T30
Interface: M-Bus
Interface type: Retrofittable (factory installed)


EW1101AC0600

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1101 for warm water
DN size: 15mm
Permanent flow: 1.6m3/h
Length: 110mm
Connection: G 3/4
Temperature class: T90
Interface: no
Interface type: Retrofittable


EW1101AC1100

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1101 for warm water
DN size: 15mm
Permanent flow: 2.5m3/h
Length: 80mm
Connection: G 3/4
Temperature class: T90
Interface: no
Interface type: Retrofittable


EW1101AC1200

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1101 for warm water
DN size: 15mm
Permanent flow: 2.5m3/h
Length: 110mm
Connection: G 3/4
Temperature class: T90
Interface: no
Interface type: Retrofittable


EW1101AC1400

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1101 for warm water
DN size: 20mm
Permanent flow: 2.5m3/h
Length: 130mm
Connection: G 1
Temperature class: T90
Interface: no
Interface type: Retrofittable


EW1101AC2000

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1101 for warm water
DN size: 20mm
Permanent flow: 4m3/h
Length: 130mm
Connection: G 1
Temperature class: T90
Interface: no
Interface type: Retrofittable


EW1101CC2800

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1101 for warm water
DN size: 25mm
Permanent flow: 6.3m3/h
Length: 260mm
Connection: G 1 1/4
Temperature class: T130
Interface: no
Interface type: Retrofittable


EW1101CC3900

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1101 for warm water
DN size: 32mm
Permanent flow: 10m3/h
Length: 260mm
Connection: G 1 1/2
Temperature class: T130
Interface: no
Interface type: Retrofittable


EW1101CC4600

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1101 for warm water
DN size: 40mm
Permanent flow: 16m3/h
Length: 300mm
Connection: G 2
Temperature class: T130
Interface: no
Interface type: Retrofittable


EW1101CM1200

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1101 for warm water, with M-Bus module fitted
DN size: 15mm
Permanent flow: 2.5m3/h
Length: 110mm
Connection: G 3/4
Temperature class: T90
Interface: M-Bus
Interface type: Retrofittable (factory installed)


EW1101CM2000

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1101 for warm water, with M-Bus module fitted
DN size: 20mm
Permanent flow: 4m3/h
Length: 130mm
Connection: G 1
Temperature class: T90
Interface: M-Bus
Interface type: Retrofittable (factory installed)


EW1101CM2800

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1101 for warm water, with M-Bus module fitted
DN size: 25mm
Permanent flow: 6.3m3/h
Length: 260mm
Connection: G 1 1/4
Temperature class: T130
Interface: M-Bus
Interface type: Retrofittable (factory installed)


EW1101CM3900

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1101 for warm water, with M-Bus module fitted
DN size: 32mm
Permanent flow: 10m3/h
Length: 260mm
Connection: G 1 1/2
Temperature class: T130
Interface: M-Bus
Interface type: Retrofittable (factory installed)


EW1101CM4600

Centraline EW110 Series Singlejet Water Meters DN15...40

Honeywell EW110 Series singlejet water meters are used for consumption metering of cold or warm water in residential potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with clip on modules to enable M-Bus or pulse out communication.
EW1100 water meters are suitable for cold water up to 30C. EW1101 water meters are suitable for warm water up to 90C or 130C.
Features: Compact design
Rotatable counter
Retrofittable clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: single jet
Display functions: DN15...20: Eight digit roller counter
DN25...40: Five digit roller counter with dials for decimal places
Approvals: MID
DN15...20: ACS, KTW
DN25...40: WRAS

EW1101 for warm water, with M-Bus module fitted
DN size: 40mm
Permanent flow: 16m3/h
Length: 300mm
Connection: G 2
Temperature class: T130
Interface: M-Bus
Interface type: Retrofittable (factory installed)


EW1200AB1500

Centraline EW120 Series Multijet Wet Dial Water Meters DN15...40

Honeywell EW120 Series multijet water meters are used for consumption metering of cold water in residential or small commercial potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with a reed switch for pulse out.
Features: Robust design with multijet flow sensor
Wet dial counter
Retrofittable reed switch for pulse out
Medium: cold potable water
Max. operating pressure: 16bar
Measuring method: multi jet
Display functions: Five digit roller counter
Approvals: MID
Temperature class: T30
Interface type: Retrofittable

EW1200 for cold water
DN size: 15mm
Permanent flow: 2.5m3/h
Length: 165mm
Connection: G 3/4


EW1200AB2200

Centraline EW120 Series Multijet Wet Dial Water Meters DN15...40

Honeywell EW120 Series multijet water meters are used for consumption metering of cold water in residential or small commercial potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with a reed switch for pulse out.
Features: Robust design with multijet flow sensor
Wet dial counter
Retrofittable reed switch for pulse out
Medium: cold potable water
Max. operating pressure: 16bar
Measuring method: multi jet
Display functions: Five digit roller counter
Approvals: MID
Temperature class: T30
Interface type: Retrofittable

EW1200 for cold water
DN size: 20mm
Permanent flow: 4m3/h
Length: 190mm
Connection: G 1


EW1200AB3600

Centraline EW120 Series Multijet Wet Dial Water Meters DN15...40

Honeywell EW120 Series multijet water meters are used for consumption metering of cold water in residential or small commercial potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with a reed switch for pulse out.
Features: Robust design with multijet flow sensor
Wet dial counter
Retrofittable reed switch for pulse out
Medium: cold potable water
Max. operating pressure: 16bar
Measuring method: multi jet
Display functions: Five digit roller counter
Approvals: MID
Temperature class: T30
Interface type: Retrofittable

EW1200 for cold water
DN size: 25mm
Permanent flow: 6.3m3/h
Length: 260mm
Connection: G 1 1/4


EW1200AB3900

Centraline EW120 Series Multijet Wet Dial Water Meters DN15...40

Honeywell EW120 Series multijet water meters are used for consumption metering of cold water in residential or small commercial potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with a reed switch for pulse out.
Features: Robust design with multijet flow sensor
Wet dial counter
Retrofittable reed switch for pulse out
Medium: cold potable water
Max. operating pressure: 16bar
Measuring method: multi jet
Display functions: Five digit roller counter
Approvals: MID
Temperature class: T30
Interface type: Retrofittable

EW1200 for cold water
DN size: 32mm
Permanent flow: 10m3/h
Length: 260mm
Connection: G 1 1/2


EW1200AB4600

Centraline EW120 Series Multijet Wet Dial Water Meters DN15...40

Honeywell EW120 Series multijet water meters are used for consumption metering of cold water in residential or small commercial potable water systems. They are available in sizes DN15 to DN40 and have a roller counter. They can be fitted with a reed switch for pulse out.
Features: Robust design with multijet flow sensor
Wet dial counter
Retrofittable reed switch for pulse out
Medium: cold potable water
Max. operating pressure: 16bar
Measuring method: multi jet
Display functions: Five digit roller counter
Approvals: MID
Temperature class: T30
Interface type: Retrofittable

EW1200 for cold water
DN size: 40mm
Permanent flow: 16m3/h
Length: 300mm
Connection: G 2


EW1300BF1200

Centraline EW130 Series Multijet Water Meters DN15...20

Honeywell EW130 Series multijet watermeters are used for flow measurement of cold or warm water in potable water systems. They are available in sizes DN15 and DN20 and have an electronic counter with optical interface as well as M-Bus or RF output. EW1300 watermeters are suitable for cold water up to 30C. EW1301 watermeters are suitable for warm water up to 90C.
Metering of cold or warm potable water.
Features: Available with either M-Bus or RF
Electronic sensor control for flow rate recording
Optical interface included as standard
Adjustable reading date for billing
Rotatable calculator
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery (10 year lifetime)
Approvals: MID
Interface type: Fixed

EW130 Series with RF for cold water
Medium: cold potable water
DN size: 15mm
Permanent flow: 2.5m3/h
Length: 110mm
Connection: G 3/4
Temperature class: T30
Max. operating pressure: 10bar
Interface: RF


EW1300BF2000

Centraline EW130 Series Multijet Water Meters DN15...20

Honeywell EW130 Series multijet watermeters are used for flow measurement of cold or warm water in potable water systems. They are available in sizes DN15 and DN20 and have an electronic counter with optical interface as well as M-Bus or RF output. EW1300 watermeters are suitable for cold water up to 30C. EW1301 watermeters are suitable for warm water up to 90C.
Metering of cold or warm potable water.
Features: Available with either M-Bus or RF
Electronic sensor control for flow rate recording
Optical interface included as standard
Adjustable reading date for billing
Rotatable calculator
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery (10 year lifetime)
Approvals: MID
Interface type: Fixed

EW130 Series with RF for cold water
Medium: cold potable water
DN size: 20mm
Permanent flow: 4m3/h
Length: 130mm
Connection: G 1
Temperature class: T30
Max. operating pressure: 16bar
Interface: RF


EW1300BM1200

Centraline EW130 Series Multijet Water Meters DN15...20

Honeywell EW130 Series multijet watermeters are used for flow measurement of cold or warm water in potable water systems. They are available in sizes DN15 and DN20 and have an electronic counter with optical interface as well as M-Bus or RF output. EW1300 watermeters are suitable for cold water up to 30C. EW1301 watermeters are suitable for warm water up to 90C.
Metering of cold or warm potable water.
Features: Available with either M-Bus or RF
Electronic sensor control for flow rate recording
Optical interface included as standard
Adjustable reading date for billing
Rotatable calculator
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery (10 year lifetime)
Approvals: MID
Interface type: Fixed

EW130 Series with M-Bus for cold water
Medium: cold potable water
DN size: 15mm
Permanent flow: 2.5m3/h
Length: 110mm
Connection: G 3/4
Temperature class: T30
Max. operating pressure: 10bar
Interface: M-Bus


EW1300BM2000

Centraline EW130 Series Multijet Water Meters DN15...20

Honeywell EW130 Series multijet watermeters are used for flow measurement of cold or warm water in potable water systems. They are available in sizes DN15 and DN20 and have an electronic counter with optical interface as well as M-Bus or RF output. EW1300 watermeters are suitable for cold water up to 30C. EW1301 watermeters are suitable for warm water up to 90C.
Metering of cold or warm potable water.
Features: Available with either M-Bus or RF
Electronic sensor control for flow rate recording
Optical interface included as standard
Adjustable reading date for billing
Rotatable calculator
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery (10 year lifetime)
Approvals: MID
Interface type: Fixed

EW130 Series with M-Bus for cold water
Medium: cold potable water
DN size: 20mm
Permanent flow: 4m3/h
Length: 130mm
Connection: G 1
Temperature class: T30
Max. operating pressure: 16bar
Interface: M-Bus


EW1301BF1200

Centraline EW130 Series Multijet Water Meters DN15...20

Honeywell EW130 Series multijet watermeters are used for flow measurement of cold or warm water in potable water systems. They are available in sizes DN15 and DN20 and have an electronic counter with optical interface as well as M-Bus or RF output. EW1300 watermeters are suitable for cold water up to 30C. EW1301 watermeters are suitable for warm water up to 90C.
Metering of cold or warm potable water.
Features: Available with either M-Bus or RF
Electronic sensor control for flow rate recording
Optical interface included as standard
Adjustable reading date for billing
Rotatable calculator
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery (10 year lifetime)
Approvals: MID
Interface type: Fixed

EW130 Series with RF for warm water
Medium: warm potable water
DN size: 15mm
Permanent flow: 2.5m3/h
Length: 110mm
Connection: G 3/4
Temperature class: T90
Max. operating pressure: 10bar
Interface: RF


EW1301BF2000

Centraline EW130 Series Multijet Water Meters DN15...20

Honeywell EW130 Series multijet watermeters are used for flow measurement of cold or warm water in potable water systems. They are available in sizes DN15 and DN20 and have an electronic counter with optical interface as well as M-Bus or RF output. EW1300 watermeters are suitable for cold water up to 30C. EW1301 watermeters are suitable for warm water up to 90C.
Metering of cold or warm potable water.
Features: Available with either M-Bus or RF
Electronic sensor control for flow rate recording
Optical interface included as standard
Adjustable reading date for billing
Rotatable calculator
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery (10 year lifetime)
Approvals: MID
Interface type: Fixed

EW130 Series with RF for warm water
Medium: warm potable water
DN size: 20mm
Permanent flow: 4m3/h
Length: 130mm
Connection: G 1
Temperature class: T90
Max. operating pressure: 16bar
Interface: RF


EW1301BM1200

Centraline EW130 Series Multijet Water Meters DN15...20

Honeywell EW130 Series multijet watermeters are used for flow measurement of cold or warm water in potable water systems. They are available in sizes DN15 and DN20 and have an electronic counter with optical interface as well as M-Bus or RF output. EW1300 watermeters are suitable for cold water up to 30C. EW1301 watermeters are suitable for warm water up to 90C.
Metering of cold or warm potable water.
Features: Available with either M-Bus or RF
Electronic sensor control for flow rate recording
Optical interface included as standard
Adjustable reading date for billing
Rotatable calculator
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery (10 year lifetime)
Approvals: MID
Interface type: Fixed

EW130 Series with M-Bus for warm water
Medium: warm potable water
DN size: 15mm
Permanent flow: 2.5m3/h
Length: 110mm
Connection: G 3/4
Temperature class: T90
Max. operating pressure: 10bar
Interface: M-Bus


EW1301BM2000

Centraline EW130 Series Multijet Water Meters DN15...20

Honeywell EW130 Series multijet watermeters are used for flow measurement of cold or warm water in potable water systems. They are available in sizes DN15 and DN20 and have an electronic counter with optical interface as well as M-Bus or RF output. EW1300 watermeters are suitable for cold water up to 30C. EW1301 watermeters are suitable for warm water up to 90C.
Metering of cold or warm potable water.
Features: Available with either M-Bus or RF
Electronic sensor control for flow rate recording
Optical interface included as standard
Adjustable reading date for billing
Rotatable calculator
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery (10 year lifetime)
Approvals: MID
Interface type: Fixed

EW130 Series with M-Bus for warm water
Medium: warm potable water
DN size: 20mm
Permanent flow: 4m3/h
Length: 130mm
Connection: G 1
Temperature class: T90
Max. operating pressure: 16bar
Interface: M-Bus


EW1710AC5000

Centraline EW171 Series Woltman Bulk Water Meters DN50...300

Honeywell EW171 Series bulk water meters are used for consumption metering of cold or warm water in potable water system networks. They are available in sizes DN50 to DN300 and have a roller counter. They can be fitted with M-Bus or pulse out clip on modules for remote readout applications.
EW1710 are suitable for cold water up to 30C. EW1711 are suitable for warm water up to 130C.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Retrofittable with clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Six-digit roller counter with dials for decimal places
Approvals: MID, KTW, WRAS
Connection: Flanges PN16
Interface type: Retrofittable

EW1710 for cold water
DN size: 50mm
Permanent flow: 40m3/h
Length: 200mm
Temperature class: T30


EW1710AC5600

Centraline EW171 Series Woltman Bulk Water Meters DN50...300

Honeywell EW171 Series bulk water meters are used for consumption metering of cold or warm water in potable water system networks. They are available in sizes DN50 to DN300 and have a roller counter. They can be fitted with M-Bus or pulse out clip on modules for remote readout applications.
EW1710 are suitable for cold water up to 30C. EW1711 are suitable for warm water up to 130C.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Retrofittable with clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Six-digit roller counter with dials for decimal places
Approvals: MID, KTW, WRAS
Connection: Flanges PN16
Interface type: Retrofittable

EW1710 for cold water
DN size: 65mm
Permanent flow: 63m3/h
Length: 200mm
Temperature class: T30


EW1710AC6500

Centraline EW171 Series Woltman Bulk Water Meters DN50...300

Honeywell EW171 Series bulk water meters are used for consumption metering of cold or warm water in potable water system networks. They are available in sizes DN50 to DN300 and have a roller counter. They can be fitted with M-Bus or pulse out clip on modules for remote readout applications.
EW1710 are suitable for cold water up to 30C. EW1711 are suitable for warm water up to 130C.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Retrofittable with clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Six-digit roller counter with dials for decimal places
Approvals: MID, KTW, WRAS
Connection: Flanges PN16
Interface type: Retrofittable

EW1710 for cold water
DN size: 80mm
Permanent flow: 100m3/h
Length: 225mm
Temperature class: T30


EW1710AC7300

Centraline EW171 Series Woltman Bulk Water Meters DN50...300

Honeywell EW171 Series bulk water meters are used for consumption metering of cold or warm water in potable water system networks. They are available in sizes DN50 to DN300 and have a roller counter. They can be fitted with M-Bus or pulse out clip on modules for remote readout applications.
EW1710 are suitable for cold water up to 30C. EW1711 are suitable for warm water up to 130C.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Retrofittable with clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Six-digit roller counter with dials for decimal places
Approvals: MID, KTW, WRAS
Connection: Flanges PN16
Interface type: Retrofittable

EW1710 for cold water
DN size: 100mm
Permanent flow: 160m3/h
Length: 250mm
Temperature class: T30


EW1710AC8100

Centraline EW171 Series Woltman Bulk Water Meters DN50...300

Honeywell EW171 Series bulk water meters are used for consumption metering of cold or warm water in potable water system networks. They are available in sizes DN50 to DN300 and have a roller counter. They can be fitted with M-Bus or pulse out clip on modules for remote readout applications.
EW1710 are suitable for cold water up to 30C. EW1711 are suitable for warm water up to 130C.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Retrofittable with clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Six-digit roller counter with dials for decimal places
Approvals: MID, KTW, WRAS
Connection: Flanges PN16
Interface type: Retrofittable

EW1710 for cold water
DN size: 125mm
Permanent flow: 250m3/h
Length: 250mm
Temperature class: T30


EW1710AC8500

Centraline EW171 Series Woltman Bulk Water Meters DN50...300

Honeywell EW171 Series bulk water meters are used for consumption metering of cold or warm water in potable water system networks. They are available in sizes DN50 to DN300 and have a roller counter. They can be fitted with M-Bus or pulse out clip on modules for remote readout applications.
EW1710 are suitable for cold water up to 30C. EW1711 are suitable for warm water up to 130C.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Retrofittable with clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Six-digit roller counter with dials for decimal places
Approvals: MID, KTW, WRAS
Connection: Flanges PN16
Interface type: Retrofittable

EW1710 for cold water
DN size: 150mm
Permanent flow: 400m3/h
Length: 300mm
Temperature class: T30


EW1710AC8900

Centraline EW171 Series Woltman Bulk Water Meters DN50...300

Honeywell EW171 Series bulk water meters are used for consumption metering of cold or warm water in potable water system networks. They are available in sizes DN50 to DN300 and have a roller counter. They can be fitted with M-Bus or pulse out clip on modules for remote readout applications.
EW1710 are suitable for cold water up to 30C. EW1711 are suitable for warm water up to 130C.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Retrofittable with clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Six-digit roller counter with dials for decimal places
Approvals: MID, KTW, WRAS
Connection: Flanges PN16
Interface type: Retrofittable

EW1710 for cold water
DN size: 200mm
Permanent flow: 630m3/h
Length: 350mm
Temperature class: T30


EW1710AC9100

Centraline EW171 Series Woltman Bulk Water Meters DN50...300

Honeywell EW171 Series bulk water meters are used for consumption metering of cold or warm water in potable water system networks. They are available in sizes DN50 to DN300 and have a roller counter. They can be fitted with M-Bus or pulse out clip on modules for remote readout applications.
EW1710 are suitable for cold water up to 30C. EW1711 are suitable for warm water up to 130C.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Retrofittable with clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Six-digit roller counter with dials for decimal places
Approvals: MID, KTW, WRAS
Connection: Flanges PN16
Interface type: Retrofittable

EW1710 for cold water
DN size: 250mm
Permanent flow: 1000m3/h
Length: 450mm
Temperature class: T30


EW1710AC9200

Centraline EW171 Series Woltman Bulk Water Meters DN50...300

Honeywell EW171 Series bulk water meters are used for consumption metering of cold or warm water in potable water system networks. They are available in sizes DN50 to DN300 and have a roller counter. They can be fitted with M-Bus or pulse out clip on modules for remote readout applications.
EW1710 are suitable for cold water up to 30C. EW1711 are suitable for warm water up to 130C.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Retrofittable with clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Six-digit roller counter with dials for decimal places
Approvals: MID, KTW, WRAS
Connection: Flanges PN16
Interface type: Retrofittable

EW1710 for cold water
DN size: 300mm
Permanent flow: 1600m3/h
Length: 500mm
Temperature class: T30


EW1711AC5000

Centraline EW171 Series Woltman Bulk Water Meters DN50...300

Honeywell EW171 Series bulk water meters are used for consumption metering of cold or warm water in potable water system networks. They are available in sizes DN50 to DN300 and have a roller counter. They can be fitted with M-Bus or pulse out clip on modules for remote readout applications.
EW1710 are suitable for cold water up to 30C. EW1711 are suitable for warm water up to 130C.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Retrofittable with clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Six-digit roller counter with dials for decimal places
Approvals: MID, KTW, WRAS
Connection: Flanges PN16
Interface type: Retrofittable

EW1711 for warm water
DN size: 50mm
Permanent flow: 25m3/h
Length: 200mm
Temperature class: T130


EW1711AC5600

Centraline EW171 Series Woltman Bulk Water Meters DN50...300

Honeywell EW171 Series bulk water meters are used for consumption metering of cold or warm water in potable water system networks. They are available in sizes DN50 to DN300 and have a roller counter. They can be fitted with M-Bus or pulse out clip on modules for remote readout applications.
EW1710 are suitable for cold water up to 30C. EW1711 are suitable for warm water up to 130C.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Retrofittable with clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Six-digit roller counter with dials for decimal places
Approvals: MID, KTW, WRAS
Connection: Flanges PN16
Interface type: Retrofittable

EW1711 for warm water
DN size: 65mm
Permanent flow: 40m3/h
Length: 200mm
Temperature class: T130


EW1711AC6500

Centraline EW171 Series Woltman Bulk Water Meters DN50...300

Honeywell EW171 Series bulk water meters are used for consumption metering of cold or warm water in potable water system networks. They are available in sizes DN50 to DN300 and have a roller counter. They can be fitted with M-Bus or pulse out clip on modules for remote readout applications.
EW1710 are suitable for cold water up to 30C. EW1711 are suitable for warm water up to 130C.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Retrofittable with clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Six-digit roller counter with dials for decimal places
Approvals: MID, KTW, WRAS
Connection: Flanges PN16
Interface type: Retrofittable

EW1711 for warm water
DN size: 80mm
Permanent flow: 63m3/h
Length: 225mm
Temperature class: T130


EW1711AC7300

Centraline EW171 Series Woltman Bulk Water Meters DN50...300

Honeywell EW171 Series bulk water meters are used for consumption metering of cold or warm water in potable water system networks. They are available in sizes DN50 to DN300 and have a roller counter. They can be fitted with M-Bus or pulse out clip on modules for remote readout applications.
EW1710 are suitable for cold water up to 30C. EW1711 are suitable for warm water up to 130C.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Retrofittable with clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Six-digit roller counter with dials for decimal places
Approvals: MID, KTW, WRAS
Connection: Flanges PN16
Interface type: Retrofittable

EW1711 for warm water
DN size: 100mm
Permanent flow: 100m3/h
Length: 250mm
Temperature class: T130


EW1711AC8100

Centraline EW171 Series Woltman Bulk Water Meters DN50...300

Honeywell EW171 Series bulk water meters are used for consumption metering of cold or warm water in potable water system networks. They are available in sizes DN50 to DN300 and have a roller counter. They can be fitted with M-Bus or pulse out clip on modules for remote readout applications.
EW1710 are suitable for cold water up to 30C. EW1711 are suitable for warm water up to 130C.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Retrofittable with clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Six-digit roller counter with dials for decimal places
Approvals: MID, KTW, WRAS
Connection: Flanges PN16
Interface type: Retrofittable

EW1711 for warm water
DN size: 125mm
Permanent flow: 160m3/h
Length: 250mm
Temperature class: T130


EW1711AC8500

Centraline EW171 Series Woltman Bulk Water Meters DN50...300

Honeywell EW171 Series bulk water meters are used for consumption metering of cold or warm water in potable water system networks. They are available in sizes DN50 to DN300 and have a roller counter. They can be fitted with M-Bus or pulse out clip on modules for remote readout applications.
EW1710 are suitable for cold water up to 30C. EW1711 are suitable for warm water up to 130C.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Retrofittable with clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Six-digit roller counter with dials for decimal places
Approvals: MID, KTW, WRAS
Connection: Flanges PN16
Interface type: Retrofittable

EW1711 for warm water
DN size: 150mm
Permanent flow: 250m3/h
Length: 300mm
Temperature class: T130


EW1711AC8900

Centraline EW171 Series Woltman Bulk Water Meters DN50...300

Honeywell EW171 Series bulk water meters are used for consumption metering of cold or warm water in potable water system networks. They are available in sizes DN50 to DN300 and have a roller counter. They can be fitted with M-Bus or pulse out clip on modules for remote readout applications.
EW1710 are suitable for cold water up to 30C. EW1711 are suitable for warm water up to 130C.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Retrofittable with clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Six-digit roller counter with dials for decimal places
Approvals: MID, KTW, WRAS
Connection: Flanges PN16
Interface type: Retrofittable

EW1711 for warm water
DN size: 200mm
Permanent flow: 400m3/h
Length: 350mm
Temperature class: T130


EW1711AC9100

Centraline EW171 Series Woltman Bulk Water Meters DN50...300

Honeywell EW171 Series bulk water meters are used for consumption metering of cold or warm water in potable water system networks. They are available in sizes DN50 to DN300 and have a roller counter. They can be fitted with M-Bus or pulse out clip on modules for remote readout applications.
EW1710 are suitable for cold water up to 30C. EW1711 are suitable for warm water up to 130C.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Retrofittable with clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Six-digit roller counter with dials for decimal places
Approvals: MID, KTW, WRAS
Connection: Flanges PN16
Interface type: Retrofittable

EW1711 for warm water
DN size: 250mm
Permanent flow: 630m3/h
Length: 450mm
Temperature class: T130


EW1711AC9200

Centraline EW171 Series Woltman Bulk Water Meters DN50...300

Honeywell EW171 Series bulk water meters are used for consumption metering of cold or warm water in potable water system networks. They are available in sizes DN50 to DN300 and have a roller counter. They can be fitted with M-Bus or pulse out clip on modules for remote readout applications.
EW1710 are suitable for cold water up to 30C. EW1711 are suitable for warm water up to 130C.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Retrofittable with clip on modules for M-Bus or pulse out
Medium: warm or cold potable water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Six-digit roller counter with dials for decimal places
Approvals: MID, KTW, WRAS
Connection: Flanges PN16
Interface type: Retrofittable

EW1711 for warm water
DN size: 300mm
Permanent flow: 1000m3/h
Length: 500mm
Temperature class: T130


EW3701AP4900

Centraline EW370 Series Woltman Flow Meters DN40...300

Honeywell EW370 Series Woltman flow meters are used for volume measuring of heating or chilled water in heating and air conditioning system networks. They are available in sizes DN40 to DN300 and have a roller counter. They are fitted with a pulse cable for connection to an energy calculator, e.g. Honeywell EW500 Series.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Pulse out as standard for connection to energy calculator
Medium: heating or chilled water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Eight digit roller counter
Approvals: MID
Connection: Flanges PN16
Media temp.: 1...130C
Interface: Pulse out
Interface type: Fixed


DN size: 40mm
Nominal flow (qp): 15m3/h
Length: 200mm


EW3701AP5000

Centraline EW370 Series Woltman Flow Meters DN40...300

Honeywell EW370 Series Woltman flow meters are used for volume measuring of heating or chilled water in heating and air conditioning system networks. They are available in sizes DN40 to DN300 and have a roller counter. They are fitted with a pulse cable for connection to an energy calculator, e.g. Honeywell EW500 Series.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Pulse out as standard for connection to energy calculator
Medium: heating or chilled water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Eight digit roller counter
Approvals: MID
Connection: Flanges PN16
Media temp.: 1...130C
Interface: Pulse out
Interface type: Fixed


DN size: 50mm
Nominal flow (qp): 15m3/h
Length: 200mm


EW3701AP5600

Centraline EW370 Series Woltman Flow Meters DN40...300

Honeywell EW370 Series Woltman flow meters are used for volume measuring of heating or chilled water in heating and air conditioning system networks. They are available in sizes DN40 to DN300 and have a roller counter. They are fitted with a pulse cable for connection to an energy calculator, e.g. Honeywell EW500 Series.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Pulse out as standard for connection to energy calculator
Medium: heating or chilled water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Eight digit roller counter
Approvals: MID
Connection: Flanges PN16
Media temp.: 1...130C
Interface: Pulse out
Interface type: Fixed


DN size: 65mm
Nominal flow (qp): 25m3/h
Length: 200mm


EW3701AP6500

Centraline EW370 Series Woltman Flow Meters DN40...300

Honeywell EW370 Series Woltman flow meters are used for volume measuring of heating or chilled water in heating and air conditioning system networks. They are available in sizes DN40 to DN300 and have a roller counter. They are fitted with a pulse cable for connection to an energy calculator, e.g. Honeywell EW500 Series.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Pulse out as standard for connection to energy calculator
Medium: heating or chilled water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Eight digit roller counter
Approvals: MID
Connection: Flanges PN16
Media temp.: 1...130C
Interface: Pulse out
Interface type: Fixed


DN size: 80mm
Nominal flow (qp): 40m3/h
Length: 200mm


EW3701AP7300

Centraline EW370 Series Woltman Flow Meters DN40...300

Honeywell EW370 Series Woltman flow meters are used for volume measuring of heating or chilled water in heating and air conditioning system networks. They are available in sizes DN40 to DN300 and have a roller counter. They are fitted with a pulse cable for connection to an energy calculator, e.g. Honeywell EW500 Series.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Pulse out as standard for connection to energy calculator
Medium: heating or chilled water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Eight digit roller counter
Approvals: MID
Connection: Flanges PN16
Media temp.: 1...130C
Interface: Pulse out
Interface type: Fixed


DN size: 100mm
Nominal flow (qp): 60m3/h
Length: 250mm


EW3701AP8100

Centraline EW370 Series Woltman Flow Meters DN40...300

Honeywell EW370 Series Woltman flow meters are used for volume measuring of heating or chilled water in heating and air conditioning system networks. They are available in sizes DN40 to DN300 and have a roller counter. They are fitted with a pulse cable for connection to an energy calculator, e.g. Honeywell EW500 Series.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Pulse out as standard for connection to energy calculator
Medium: heating or chilled water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Eight digit roller counter
Approvals: MID
Connection: Flanges PN16
Media temp.: 1...130C
Interface: Pulse out
Interface type: Fixed


DN size: 125mm
Nominal flow (qp): 100m3/h
Length: 250mm


EW3701AP8500

Centraline EW370 Series Woltman Flow Meters DN40...300

Honeywell EW370 Series Woltman flow meters are used for volume measuring of heating or chilled water in heating and air conditioning system networks. They are available in sizes DN40 to DN300 and have a roller counter. They are fitted with a pulse cable for connection to an energy calculator, e.g. Honeywell EW500 Series.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Pulse out as standard for connection to energy calculator
Medium: heating or chilled water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Eight digit roller counter
Approvals: MID
Connection: Flanges PN16
Media temp.: 1...130C
Interface: Pulse out
Interface type: Fixed


DN size: 150mm
Nominal flow (qp): 200m3/h
Length: 300mm


EW3701AP8900

Centraline EW370 Series Woltman Flow Meters DN40...300

Honeywell EW370 Series Woltman flow meters are used for volume measuring of heating or chilled water in heating and air conditioning system networks. They are available in sizes DN40 to DN300 and have a roller counter. They are fitted with a pulse cable for connection to an energy calculator, e.g. Honeywell EW500 Series.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Pulse out as standard for connection to energy calculator
Medium: heating or chilled water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Eight digit roller counter
Approvals: MID
Connection: Flanges PN16
Media temp.: 1...130C
Interface: Pulse out
Interface type: Fixed


DN size: 200mm
Nominal flow (qp): 250m3/h
Length: 350mm


EW3701AP9100

Centraline EW370 Series Woltman Flow Meters DN40...300

Honeywell EW370 Series Woltman flow meters are used for volume measuring of heating or chilled water in heating and air conditioning system networks. They are available in sizes DN40 to DN300 and have a roller counter. They are fitted with a pulse cable for connection to an energy calculator, e.g. Honeywell EW500 Series.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Pulse out as standard for connection to energy calculator
Medium: heating or chilled water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Eight digit roller counter
Approvals: MID
Connection: Flanges PN16
Media temp.: 1...130C
Interface: Pulse out
Interface type: Fixed


DN size: 250mm
Nominal flow (qp): 400m3/h
Length: 450mm


EW3701AP9203

Centraline EW370 Series Woltman Flow Meters DN40...300

Honeywell EW370 Series Woltman flow meters are used for volume measuring of heating or chilled water in heating and air conditioning system networks. They are available in sizes DN40 to DN300 and have a roller counter. They are fitted with a pulse cable for connection to an energy calculator, e.g. Honeywell EW500 Series.
Features: Robust design with Woltman WP flow sensor
Available up to DN300
Pulse out as standard for connection to energy calculator
Medium: heating or chilled water
Max. operating pressure: 16bar
Measuring method: woltmann wheel
Display functions: Eight digit roller counter
Approvals: MID
Connection: Flanges PN16
Media temp.: 1...130C
Interface: Pulse out
Interface type: Fixed


DN size: 300mm
Nominal flow (qp): 600m3/h
Length: 500mm


EW447A0100

Centraline EW447, EW450 Multijet Heat Meters

Static compact hydronic meter with electronic measurement, consisting of electronic energy calculator and mechanical flowmeter.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Suitable for heating water (EW447) or heating and chilled water (EW450)
No calming leg required on inlet or outlet
Optional remote readout via M-bus or pulse out
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery with 12 year nominal lifetime
Approvals: MID
Dynamic range: 1:100
Media temp.: 5...90C
Max. operating pressure: 16bar

EW447 Multijet Heat Meters for heating water
Medium: heating water
DN size: 15mm
Nominal flow (qp): 0.6m3/h
Length: 110mm
Connection: G 3/4
Interface: no
Interface type: no


EW447A1200

Centraline EW447, EW450 Multijet Heat Meters

Static compact hydronic meter with electronic measurement, consisting of electronic energy calculator and mechanical flowmeter.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Suitable for heating water (EW447) or heating and chilled water (EW450)
No calming leg required on inlet or outlet
Optional remote readout via M-bus or pulse out
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery with 12 year nominal lifetime
Approvals: MID
Dynamic range: 1:100
Media temp.: 5...90C
Max. operating pressure: 16bar

EW447 Multijet Heat Meters for heating water
Medium: heating water
DN size: 15mm
Nominal flow (qp): 1.5m3/h
Length: 110mm
Connection: G 3/4
Interface: no
Interface type: no


EW447A2000

Centraline EW447, EW450 Multijet Heat Meters

Static compact hydronic meter with electronic measurement, consisting of electronic energy calculator and mechanical flowmeter.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Suitable for heating water (EW447) or heating and chilled water (EW450)
No calming leg required on inlet or outlet
Optional remote readout via M-bus or pulse out
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery with 12 year nominal lifetime
Approvals: MID
Dynamic range: 1:100
Media temp.: 5...90C
Max. operating pressure: 16bar

EW447 Multijet Heat Meters for heating water
Medium: heating water
DN size: 20mm
Nominal flow (qp): 2.5m3/h
Length: 130mm
Connection: G 1
Interface: no
Interface type: no


EW447M0100

Centraline EW447, EW450 Multijet Heat Meters

Static compact hydronic meter with electronic measurement, consisting of electronic energy calculator and mechanical flowmeter.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Suitable for heating water (EW447) or heating and chilled water (EW450)
No calming leg required on inlet or outlet
Optional remote readout via M-bus or pulse out
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery with 12 year nominal lifetime
Approvals: MID
Dynamic range: 1:100
Media temp.: 5...90C
Max. operating pressure: 16bar

EW447 Multijet Heat Meters for heating water
Medium: heating water
DN size: 15mm
Nominal flow (qp): 0.6m3/h
Length: 110mm
Connection: G 3/4
Interface: M-Bus
Interface type: Fixed


EW447M1200

Centraline EW447, EW450 Multijet Heat Meters

Static compact hydronic meter with electronic measurement, consisting of electronic energy calculator and mechanical flowmeter.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Suitable for heating water (EW447) or heating and chilled water (EW450)
No calming leg required on inlet or outlet
Optional remote readout via M-bus or pulse out
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery with 12 year nominal lifetime
Approvals: MID
Dynamic range: 1:100
Media temp.: 5...90C
Max. operating pressure: 16bar

EW447 Multijet Heat Meters for heating water
Medium: heating water
DN size: 15mm
Nominal flow (qp): 1.5m3/h
Length: 110mm
Connection: G 3/4
Interface: M-Bus
Interface type: Fixed


EW447M2000

Centraline EW447, EW450 Multijet Heat Meters

Static compact hydronic meter with electronic measurement, consisting of electronic energy calculator and mechanical flowmeter.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Suitable for heating water (EW447) or heating and chilled water (EW450)
No calming leg required on inlet or outlet
Optional remote readout via M-bus or pulse out
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery with 12 year nominal lifetime
Approvals: MID
Dynamic range: 1:100
Media temp.: 5...90C
Max. operating pressure: 16bar

EW447 Multijet Heat Meters for heating water
Medium: heating water
DN size: 20mm
Nominal flow (qp): 2.5m3/h
Length: 130mm
Connection: G 1
Interface: M-Bus
Interface type: Fixed


EW447P0100

Centraline EW447, EW450 Multijet Heat Meters

Static compact hydronic meter with electronic measurement, consisting of electronic energy calculator and mechanical flowmeter.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Suitable for heating water (EW447) or heating and chilled water (EW450)
No calming leg required on inlet or outlet
Optional remote readout via M-bus or pulse out
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery with 12 year nominal lifetime
Approvals: MID
Dynamic range: 1:100
Media temp.: 5...90C
Max. operating pressure: 16bar

EW447 Multijet Heat Meters for heating water
Medium: heating water
DN size: 15mm
Nominal flow (qp): 0.6m3/h
Length: 110mm
Connection: G 3/4
Interface: Pulse out
Interface type: Fixed


EW447P1200

Centraline EW447, EW450 Multijet Heat Meters

Static compact hydronic meter with electronic measurement, consisting of electronic energy calculator and mechanical flowmeter.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Suitable for heating water (EW447) or heating and chilled water (EW450)
No calming leg required on inlet or outlet
Optional remote readout via M-bus or pulse out
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery with 12 year nominal lifetime
Approvals: MID
Dynamic range: 1:100
Media temp.: 5...90C
Max. operating pressure: 16bar

EW447 Multijet Heat Meters for heating water
Medium: heating water
DN size: 15mm
Nominal flow (qp): 1.5m3/h
Length: 110mm
Connection: G 3/4
Interface: Pulse out
Interface type: Fixed


EW447P2000

Centraline EW447, EW450 Multijet Heat Meters

Static compact hydronic meter with electronic measurement, consisting of electronic energy calculator and mechanical flowmeter.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Suitable for heating water (EW447) or heating and chilled water (EW450)
No calming leg required on inlet or outlet
Optional remote readout via M-bus or pulse out
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery with 12 year nominal lifetime
Approvals: MID
Dynamic range: 1:100
Media temp.: 5...90C
Max. operating pressure: 16bar

EW447 Multijet Heat Meters for heating water
Medium: heating water
DN size: 20mm
Nominal flow (qp): 2.5m3/h
Length: 130mm
Connection: G 1
Interface: Pulse out
Interface type: Fixed


EW450A0100

Centraline EW447, EW450 Multijet Heat Meters

Static compact hydronic meter with electronic measurement, consisting of electronic energy calculator and mechanical flowmeter.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Suitable for heating water (EW447) or heating and chilled water (EW450)
No calming leg required on inlet or outlet
Optional remote readout via M-bus or pulse out
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery with 12 year nominal lifetime
Approvals: MID
Dynamic range: 1:100
Media temp.: 5...90C
Max. operating pressure: 16bar

EW450 Multijet Heat Meters for heating and chilled water
Medium: heating or chilled water
DN size: 15mm
Nominal flow (qp): 0.6m3/h
Length: 110mm
Connection: G 3/4
Interface: no
Interface type: no


EW450A1200

Centraline EW447, EW450 Multijet Heat Meters

Static compact hydronic meter with electronic measurement, consisting of electronic energy calculator and mechanical flowmeter.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Suitable for heating water (EW447) or heating and chilled water (EW450)
No calming leg required on inlet or outlet
Optional remote readout via M-bus or pulse out
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery with 12 year nominal lifetime
Approvals: MID
Dynamic range: 1:100
Media temp.: 5...90C
Max. operating pressure: 16bar

EW450 Multijet Heat Meters for heating and chilled water
Medium: heating or chilled water
DN size: 15mm
Nominal flow (qp): 1.5m3/h
Length: 110mm
Connection: G 3/4
Interface: no
Interface type: no


EW450A2000

Centraline EW447, EW450 Multijet Heat Meters

Static compact hydronic meter with electronic measurement, consisting of electronic energy calculator and mechanical flowmeter.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Suitable for heating water (EW447) or heating and chilled water (EW450)
No calming leg required on inlet or outlet
Optional remote readout via M-bus or pulse out
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery with 12 year nominal lifetime
Approvals: MID
Dynamic range: 1:100
Media temp.: 5...90C
Max. operating pressure: 16bar

EW450 Multijet Heat Meters for heating and chilled water
Medium: heating or chilled water
DN size: 20mm
Nominal flow (qp): 2.5m3/h
Length: 130mm
Connection: G 1
Interface: no
Interface type: no


EW450M0100

Centraline EW447, EW450 Multijet Heat Meters

Static compact hydronic meter with electronic measurement, consisting of electronic energy calculator and mechanical flowmeter.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Suitable for heating water (EW447) or heating and chilled water (EW450)
No calming leg required on inlet or outlet
Optional remote readout via M-bus or pulse out
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery with 12 year nominal lifetime
Approvals: MID
Dynamic range: 1:100
Media temp.: 5...90C
Max. operating pressure: 16bar

EW450 Multijet Heat Meters for heating and chilled water
Medium: heating or chilled water
DN size: 15mm
Nominal flow (qp): 0.6m3/h
Length: 110mm
Connection: G 3/4
Interface: M-Bus
Interface type: Fixed


EW450M1200

Centraline EW447, EW450 Multijet Heat Meters

Static compact hydronic meter with electronic measurement, consisting of electronic energy calculator and mechanical flowmeter.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Suitable for heating water (EW447) or heating and chilled water (EW450)
No calming leg required on inlet or outlet
Optional remote readout via M-bus or pulse out
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery with 12 year nominal lifetime
Approvals: MID
Dynamic range: 1:100
Media temp.: 5...90C
Max. operating pressure: 16bar

EW450 Multijet Heat Meters for heating and chilled water
Medium: heating or chilled water
DN size: 15mm
Nominal flow (qp): 1.5m3/h
Length: 110mm
Connection: G 3/4
Interface: M-Bus
Interface type: Fixed


EW450M2000

Centraline EW447, EW450 Multijet Heat Meters

Static compact hydronic meter with electronic measurement, consisting of electronic energy calculator and mechanical flowmeter.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Suitable for heating water (EW447) or heating and chilled water (EW450)
No calming leg required on inlet or outlet
Optional remote readout via M-bus or pulse out
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery with 12 year nominal lifetime
Approvals: MID
Dynamic range: 1:100
Media temp.: 5...90C
Max. operating pressure: 16bar

EW450 Multijet Heat Meters for heating and chilled water
Medium: heating or chilled water
DN size: 20mm
Nominal flow (qp): 2.5m3/h
Length: 130mm
Connection: G 1
Interface: M-Bus
Interface type: Fixed


EW450P0100

Centraline EW447, EW450 Multijet Heat Meters

Static compact hydronic meter with electronic measurement, consisting of electronic energy calculator and mechanical flowmeter.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Suitable for heating water (EW447) or heating and chilled water (EW450)
No calming leg required on inlet or outlet
Optional remote readout via M-bus or pulse out
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery with 12 year nominal lifetime
Approvals: MID
Dynamic range: 1:100
Media temp.: 5...90C
Max. operating pressure: 16bar

EW450 Multijet Heat Meters for heating and chilled water
Medium: heating or chilled water
DN size: 15mm
Nominal flow (qp): 0.6m3/h
Length: 110mm
Connection: G 3/4
Interface: Pulse out
Interface type: Fixed


EW450P1200

Centraline EW447, EW450 Multijet Heat Meters

Static compact hydronic meter with electronic measurement, consisting of electronic energy calculator and mechanical flowmeter.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Suitable for heating water (EW447) or heating and chilled water (EW450)
No calming leg required on inlet or outlet
Optional remote readout via M-bus or pulse out
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery with 12 year nominal lifetime
Approvals: MID
Dynamic range: 1:100
Media temp.: 5...90C
Max. operating pressure: 16bar

EW450 Multijet Heat Meters for heating and chilled water
Medium: heating or chilled water
DN size: 15mm
Nominal flow (qp): 1.5m3/h
Length: 110mm
Connection: G 3/4
Interface: Pulse out
Interface type: Fixed


EW450P2000

Centraline EW447, EW450 Multijet Heat Meters

Static compact hydronic meter with electronic measurement, consisting of electronic energy calculator and mechanical flowmeter.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Suitable for heating water (EW447) or heating and chilled water (EW450)
No calming leg required on inlet or outlet
Optional remote readout via M-bus or pulse out
Measuring method: multi jet
Display functions: LCD, 7-digit
Power source: Lithium battery with 12 year nominal lifetime
Approvals: MID
Dynamic range: 1:100
Media temp.: 5...90C
Max. operating pressure: 16bar

EW450 Multijet Heat Meters for heating and chilled water
Medium: heating or chilled water
DN size: 20mm
Nominal flow (qp): 2.5m3/h
Length: 130mm
Connection: G 1
Interface: Pulse out
Interface type: Fixed


EW473P8303

Centraline EW473 Ultrasonic Flowmeters

Honeywell EW473 Series ultrasonic flow meters are used for flow measurement of heating or cooling water in hydronic heating, cooling or air conditioning systems. They are typically used with an EW500 Series energy calculator. The combination of flow meter and energy calculator has the same functionality as a heat meter. EW473 Series flow meters are equipped with two galvanically isolated digital outputs for easy connection to a calculator (potential-free).
Features: No pressure loss
Rugged design
Indifferent to dirt in the system
Measuring method: ultrasonic
Display functions: LCD, 8+2-digit
Media temp.: 2...120C
Power source: 230Vac, 50...60Hz
Approvals: MID
Medium: heating or chilled water
Connection: Flanges PN16
Max. operating pressure: 16bar
Interface: Pulse out
Interface type: Fixed


DN size: 100mm
Nominal flow (qp): 120m3/h
Length: 350mm


EW473P8725

Centraline EW473 Ultrasonic Flowmeters

Honeywell EW473 Series ultrasonic flow meters are used for flow measurement of heating or cooling water in hydronic heating, cooling or air conditioning systems. They are typically used with an EW500 Series energy calculator. The combination of flow meter and energy calculator has the same functionality as a heat meter. EW473 Series flow meters are equipped with two galvanically isolated digital outputs for easy connection to a calculator (potential-free).
Features: No pressure loss
Rugged design
Indifferent to dirt in the system
Measuring method: ultrasonic
Display functions: LCD, 8+2-digit
Media temp.: 2...120C
Power source: 230Vac, 50...60Hz
Approvals: MID
Medium: heating or chilled water
Connection: Flanges PN16
Max. operating pressure: 16bar
Interface: Pulse out
Interface type: Fixed


DN size: 125mm
Nominal flow (qp): 200m3/h
Length: 350mm


EW473P9025

Centraline EW473 Ultrasonic Flowmeters

Honeywell EW473 Series ultrasonic flow meters are used for flow measurement of heating or cooling water in hydronic heating, cooling or air conditioning systems. They are typically used with an EW500 Series energy calculator. The combination of flow meter and energy calculator has the same functionality as a heat meter. EW473 Series flow meters are equipped with two galvanically isolated digital outputs for easy connection to a calculator (potential-free).
Features: No pressure loss
Rugged design
Indifferent to dirt in the system
Measuring method: ultrasonic
Display functions: LCD, 8+2-digit
Media temp.: 2...120C
Power source: 230Vac, 50...60Hz
Approvals: MID
Medium: heating or chilled water
Connection: Flanges PN16
Max. operating pressure: 16bar
Interface: Pulse out
Interface type: Fixed


DN size: 150mm
Nominal flow (qp): 300m3/h
Length: 500mm


EW473P9125

Centraline EW473 Ultrasonic Flowmeters

Honeywell EW473 Series ultrasonic flow meters are used for flow measurement of heating or cooling water in hydronic heating, cooling or air conditioning systems. They are typically used with an EW500 Series energy calculator. The combination of flow meter and energy calculator has the same functionality as a heat meter. EW473 Series flow meters are equipped with two galvanically isolated digital outputs for easy connection to a calculator (potential-free).
Features: No pressure loss
Rugged design
Indifferent to dirt in the system
Measuring method: ultrasonic
Display functions: LCD, 8+2-digit
Media temp.: 2...120C
Power source: 230Vac, 50...60Hz
Approvals: MID
Medium: heating or chilled water
Connection: Flanges PN16
Max. operating pressure: 16bar
Interface: Pulse out
Interface type: Fixed


DN size: 200mm
Nominal flow (qp): 500m3/h
Length: 500mm


EW473P9225

Centraline EW473 Ultrasonic Flowmeters

Honeywell EW473 Series ultrasonic flow meters are used for flow measurement of heating or cooling water in hydronic heating, cooling or air conditioning systems. They are typically used with an EW500 Series energy calculator. The combination of flow meter and energy calculator has the same functionality as a heat meter. EW473 Series flow meters are equipped with two galvanically isolated digital outputs for easy connection to a calculator (potential-free).
Features: No pressure loss
Rugged design
Indifferent to dirt in the system
Measuring method: ultrasonic
Display functions: LCD, 8+2-digit
Media temp.: 2...120C
Power source: 230Vac, 50...60Hz
Approvals: MID
Medium: heating or chilled water
Connection: Flanges PN16
Max. operating pressure: 16bar
Interface: Pulse out
Interface type: Fixed


DN size: 250mm
Nominal flow (qp): 800m3/h
Length: 600mm


EW473P9303

Centraline EW473 Ultrasonic Flowmeters

Honeywell EW473 Series ultrasonic flow meters are used for flow measurement of heating or cooling water in hydronic heating, cooling or air conditioning systems. They are typically used with an EW500 Series energy calculator. The combination of flow meter and energy calculator has the same functionality as a heat meter. EW473 Series flow meters are equipped with two galvanically isolated digital outputs for easy connection to a calculator (potential-free).
Features: No pressure loss
Rugged design
Indifferent to dirt in the system
Measuring method: ultrasonic
Display functions: LCD, 8+2-digit
Media temp.: 2...120C
Power source: 230Vac, 50...60Hz
Approvals: MID
Medium: heating or chilled water
Connection: Flanges PN16
Max. operating pressure: 16bar
Interface: Pulse out
Interface type: Fixed


DN size: 300mm
Nominal flow (qp): 1120m3/h
Length: 500mm


EW473P9425

Centraline EW473 Ultrasonic Flowmeters

Honeywell EW473 Series ultrasonic flow meters are used for flow measurement of heating or cooling water in hydronic heating, cooling or air conditioning systems. They are typically used with an EW500 Series energy calculator. The combination of flow meter and energy calculator has the same functionality as a heat meter. EW473 Series flow meters are equipped with two galvanically isolated digital outputs for easy connection to a calculator (potential-free).
Features: No pressure loss
Rugged design
Indifferent to dirt in the system
Measuring method: ultrasonic
Display functions: LCD, 8+2-digit
Media temp.: 2...120C
Power source: 230Vac, 50...60Hz
Approvals: MID
Medium: heating or chilled water
Connection: Flanges PN16
Max. operating pressure: 16bar
Interface: Pulse out
Interface type: Fixed


DN size: 350mm
Nominal flow (qp): 1500.0m3/h
Length: 550mm


EW473P9525

Centraline EW473 Ultrasonic Flowmeters

Honeywell EW473 Series ultrasonic flow meters are used for flow measurement of heating or cooling water in hydronic heating, cooling or air conditioning systems. They are typically used with an EW500 Series energy calculator. The combination of flow meter and energy calculator has the same functionality as a heat meter. EW473 Series flow meters are equipped with two galvanically isolated digital outputs for easy connection to a calculator (potential-free).
Features: No pressure loss
Rugged design
Indifferent to dirt in the system
Measuring method: ultrasonic
Display functions: LCD, 8+2-digit
Media temp.: 2...120C
Power source: 230Vac, 50...60Hz
Approvals: MID
Medium: heating or chilled water
Connection: Flanges PN16
Max. operating pressure: 16bar
Interface: Pulse out
Interface type: Fixed


DN size: 400mm
Nominal flow (qp): 1900m3/h
Length: 600mm


EW473P9625

Centraline EW473 Ultrasonic Flowmeters

Honeywell EW473 Series ultrasonic flow meters are used for flow measurement of heating or cooling water in hydronic heating, cooling or air conditioning systems. They are typically used with an EW500 Series energy calculator. The combination of flow meter and energy calculator has the same functionality as a heat meter. EW473 Series flow meters are equipped with two galvanically isolated digital outputs for easy connection to a calculator (potential-free).
Features: No pressure loss
Rugged design
Indifferent to dirt in the system
Measuring method: ultrasonic
Display functions: LCD, 8+2-digit
Media temp.: 2...120C
Power source: 230Vac, 50...60Hz
Approvals: MID
Medium: heating or chilled water
Connection: Flanges PN16
Max. operating pressure: 16bar
Interface: Pulse out
Interface type: Fixed


DN size: 500mm
Nominal flow (qp): 2950m3/h
Length: 625mm


EW473P9925

Centraline EW473 Ultrasonic Flowmeters

Honeywell EW473 Series ultrasonic flow meters are used for flow measurement of heating or cooling water in hydronic heating, cooling or air conditioning systems. They are typically used with an EW500 Series energy calculator. The combination of flow meter and energy calculator has the same functionality as a heat meter. EW473 Series flow meters are equipped with two galvanically isolated digital outputs for easy connection to a calculator (potential-free).
Features: No pressure loss
Rugged design
Indifferent to dirt in the system
Measuring method: ultrasonic
Display functions: LCD, 8+2-digit
Media temp.: 2...120C
Power source: 230Vac, 50...60Hz
Approvals: MID
Medium: heating or chilled water
Connection: Flanges PN16
Max. operating pressure: 16bar
Interface: Pulse out
Interface type: Fixed


DN size: 600mm
Nominal flow (qp): 4300m3/h
Length: 750mm


EW7730A1200

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7730A Ultrasonic hydronic meter for heating applications
Medium: heating water
DN size: 15mm
Nominal flow (qp): 1.5m3/h
Length: 110mm
Connection: G 3/4
Media temp.: 5...130C
Max. operating pressure: 16bar
Interface: no
Interface type: Retrofittable (two slots)


EW7730A1400

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7730A Ultrasonic hydronic meter for heating applications
Medium: heating water
DN size: 20mm
Nominal flow (qp): 1.5m3/h
Length: 130mm
Connection: G 1
Media temp.: 5...130C
Max. operating pressure: 16bar
Interface: no
Interface type: Retrofittable (two slots)


EW7730A2000

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7730A Ultrasonic hydronic meter for heating applications
Medium: heating water
DN size: 20mm
Nominal flow (qp): 2.5m3/h
Length: 130mm
Connection: G 1
Media temp.: 5...130C
Max. operating pressure: 16bar
Interface: no
Interface type: Retrofittable (two slots)


EW7730A3600

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7730A Ultrasonic hydronic meter for heating applications
Medium: heating water
DN size: 25mm
Nominal flow (qp): 6m3/h
Length: 260mm
Connection: G 1 1/4
Media temp.: 5...150C
Max. operating pressure: 16bar
Interface: no
Interface type: Retrofittable (two slots)


EW7730A4000

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7730A Ultrasonic hydronic meter for heating applications
Medium: heating water
DN size: 32mm
Nominal flow (qp): 6m3/h
Length: 260mm
Connection: Flanges PN25
Media temp.: 5...150C
Max. operating pressure: 25bar
Interface: no
Interface type: Retrofittable (two slots)


EW7730A4600

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7730A Ultrasonic hydronic meter for heating applications
Medium: heating water
DN size: 40mm
Nominal flow (qp): 10m3/h
Length: 300mm
Connection: G 2
Media temp.: 5...150C
Max. operating pressure: 16bar
Interface: no
Interface type: Retrofittable (two slots)


EW7730A4800

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7730A Ultrasonic hydronic meter for heating applications
Medium: heating water
DN size: 40mm
Nominal flow (qp): 10m3/h
Length: 300mm
Connection: Flanges PN25
Media temp.: 5...150C
Max. operating pressure: 25bar
Interface: no
Interface type: Retrofittable (two slots)


EW7730A5200

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7730A Ultrasonic hydronic meter for heating applications
Medium: heating water
DN size: 50mm
Nominal flow (qp): 15m3/h
Length: 270mm
Connection: Flanges PN25
Media temp.: 5...150C
Max. operating pressure: 25bar
Interface: no
Interface type: Retrofittable (two slots)


EW7730A6000

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7730A Ultrasonic hydronic meter for heating applications
Medium: heating water
DN size: 65mm
Nominal flow (qp): 25m3/h
Length: 300mm
Connection: Flanges PN25
Media temp.: 5...150C
Max. operating pressure: 25bar
Interface: no
Interface type: Retrofittable (two slots)


EW7730A7000

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7730A Ultrasonic hydronic meter for heating applications
Medium: heating water
DN size: 80mm
Nominal flow (qp): 40m3/h
Length: 300mm
Connection: Flanges PN25
Media temp.: 5...150C
Max. operating pressure: 25bar
Interface: no
Interface type: Retrofittable (two slots)


EW7730A7800

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7730A Ultrasonic hydronic meter for heating applications
Medium: heating water
DN size: 100mm
Nominal flow (qp): 60m3/h
Length: 360mm
Connection: Flanges PN25
Media temp.: 5...150C
Max. operating pressure: 25bar
Interface: no
Interface type: Retrofittable (two slots)


EW7730F1200

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7730F Ultrasonic hydronic meter for heating applications, with RF on board
Medium: heating water
DN size: 15mm
Nominal flow (qp): 1.5m3/h
Length: 110mm
Connection: G 3/4
Media temp.: 5...130C
Max. operating pressure: 16bar
Interface: RF
Interface type: Fixed


EW7730F2000

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7730F Ultrasonic hydronic meter for heating applications, with RF on board
Medium: heating water
DN size: 20mm
Nominal flow (qp): 2.5m3/h
Length: 130mm
Connection: G 1
Media temp.: 5...130C
Max. operating pressure: 16bar
Interface: RF
Interface type: Fixed


EW7730K1200

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7730K Ultrasonic hydronic meter for heating applications; with M-Bus and pulse input modules
Medium: heating water
DN size: 15mm
Nominal flow (qp): 1.5m3/h
Length: 110mm
Connection: G 3/4
Media temp.: 5...130C
Max. operating pressure: 16bar
Interface: M-Bus + pulse in
Interface type: Retrofittable (factory installed)


EW7730K2000

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7730K Ultrasonic hydronic meter for heating applications; with M-Bus and pulse input modules
Medium: heating water
DN size: 20mm
Nominal flow (qp): 2.5m3/h
Length: 130mm
Connection: G 1
Media temp.: 5...130C
Max. operating pressure: 16bar
Interface: M-Bus + pulse in
Interface type: Retrofittable (factory installed)


EW7730M1200

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7730M Ultrasonic hydronic meter for heating applications, with M-Bus module
Medium: heating water
DN size: 15mm
Nominal flow (qp): 1.5m3/h
Length: 110mm
Connection: G 3/4
Media temp.: 5...130C
Max. operating pressure: 16bar
Interface: M-Bus
Interface type: Retrofittable (factory installed)


EW7730M2000

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7730M Ultrasonic hydronic meter for heating applications, with M-Bus module
Medium: heating water
DN size: 20mm
Nominal flow (qp): 2.5m3/h
Length: 130mm
Connection: G 1
Media temp.: 5...130C
Max. operating pressure: 16bar
Interface: M-Bus
Interface type: Retrofittable (factory installed)


EW7730M3600

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7730M Ultrasonic hydronic meter for heating applications, with M-Bus module
Medium: heating water
DN size: 25mm
Nominal flow (qp): 6m3/h
Length: 260mm
Connection: G 1 1/4
Media temp.: 5...150C
Max. operating pressure: 16bar
Interface: M-Bus
Interface type: Retrofittable (factory installed)


EW7731A1200

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7731A Ultrasonic hydronic meter for heating and cooling applications
Medium: heating or chilled water
DN size: 15mm
Nominal flow (qp): 1.5m3/h
Length: 110mm
Connection: G 3/4
Media temp.: 5...105C
Max. operating pressure: 16bar
Interface: no
Interface type: Retrofittable (two slots)


EW7731A2000

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7731A Ultrasonic hydronic meter for heating and cooling applications
Medium: heating or chilled water
DN size: 20mm
Nominal flow (qp): 2.5m3/h
Length: 130mm
Connection: G 1
Media temp.: 5...105C
Max. operating pressure: 16bar
Interface: no
Interface type: Retrofittable (two slots)


EW7731A3600

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7731A Ultrasonic hydronic meter for heating and cooling applications
Medium: heating or chilled water
DN size: 25mm
Nominal flow (qp): 6m3/h
Length: 260mm
Connection: G 1 1/4
Media temp.: 5...105C
Max. operating pressure: 16bar
Interface: no
Interface type: Retrofittable (two slots)


EW7731A4000

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7731A Ultrasonic hydronic meter for heating and cooling applications
Medium: heating or chilled water
DN size: 32mm
Nominal flow (qp): 6m3/h
Length: 260mm
Connection: Flanges PN25
Media temp.: 5...105C
Max. operating pressure: 25bar
Interface: no
Interface type: Retrofittable (two slots)


EW7731A4600

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7731A Ultrasonic hydronic meter for heating and cooling applications
Medium: heating or chilled water
DN size: 40mm
Nominal flow (qp): 10m3/h
Length: 300mm
Connection: G 2
Media temp.: 5...105C
Max. operating pressure: 16bar
Interface: no
Interface type: Retrofittable (two slots)


EW7731A4800

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7731A Ultrasonic hydronic meter for heating and cooling applications
Medium: heating or chilled water
DN size: 40mm
Nominal flow (qp): 10m3/h
Length: 300mm
Connection: Flanges PN25
Media temp.: 5...105C
Max. operating pressure: 25bar
Interface: no
Interface type: Retrofittable (two slots)


EW7731A5200

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7731A Ultrasonic hydronic meter for heating and cooling applications
Medium: heating or chilled water
DN size: 50mm
Nominal flow (qp): 15m3/h
Length: 270mm
Connection: Flanges PN25
Media temp.: 5...105C
Max. operating pressure: 25bar
Interface: no
Interface type: Retrofittable (two slots)


EW7731A6000

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7731A Ultrasonic hydronic meter for heating and cooling applications
Medium: heating or chilled water
DN size: 65mm
Nominal flow (qp): 25m3/h
Length: 300mm
Connection: Flanges PN25
Media temp.: 5...105C
Max. operating pressure: 25bar
Interface: no
Interface type: Retrofittable (two slots)


EW7731A7000

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7731A Ultrasonic hydronic meter for heating and cooling applications
Medium: heating or chilled water
DN size: 80mm
Nominal flow (qp): 40m3/h
Length: 300mm
Connection: Flanges PN25
Media temp.: 5...105C
Max. operating pressure: 25bar
Interface: no
Interface type: Retrofittable (two slots)


EW7731A7800

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7731A Ultrasonic hydronic meter for heating and cooling applications
Medium: heating or chilled water
DN size: 100mm
Nominal flow (qp): 60m3/h
Length: 360mm
Connection: Flanges PN25
Media temp.: 5...105C
Max. operating pressure: 25bar
Interface: no
Interface type: Retrofittable (two slots)


EW7731F1200

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7731F Ultrasonic hydronic meter for heating and cooling applications; with RF and two pulse inputs
Medium: heating or chilled water
DN size: 15mm
Nominal flow (qp): 1.5m3/h
Length: 110mm
Connection: G 3/4
Media temp.: 5...105C
Max. operating pressure: 16bar
Interface: RF
Interface type: Fixed


EW7731F2000

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7731F Ultrasonic hydronic meter for heating and cooling applications; with RF and two pulse inputs
Medium: heating or chilled water
DN size: 20mm
Nominal flow (qp): 2.5m3/h
Length: 130mm
Connection: G 1
Media temp.: 5...105C
Max. operating pressure: 16bar
Interface: RF
Interface type: Fixed


EW7731M1200

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7731M Ultrasonic hydronic meter for heating and cooling applications; with M-Bus module
Medium: heating or chilled water
DN size: 15mm
Nominal flow (qp): 1.5m3/h
Length: 110mm
Connection: G 3/4
Media temp.: 5...105C
Max. operating pressure: 16bar
Interface: M-Bus
Interface type: Retrofittable (factory installed)


EW7731M2000

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7731M Ultrasonic hydronic meter for heating and cooling applications; with M-Bus module
Medium: heating or chilled water
DN size: 20mm
Nominal flow (qp): 2.5m3/h
Length: 130mm
Connection: G 1
Media temp.: 5...105C
Max. operating pressure: 16bar
Interface: M-Bus
Interface type: Retrofittable (factory installed)


EW7731M3600

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7731M Ultrasonic hydronic meter for heating and cooling applications; with M-Bus module
Medium: heating or chilled water
DN size: 25mm
Nominal flow (qp): 6m3/h
Length: 260mm
Connection: G 1 1/4
Media temp.: 5...105C
Max. operating pressure: 16bar
Interface: M-Bus
Interface type: Retrofittable (factory installed)


EW7731M4000

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7731M Ultrasonic hydronic meter for heating and cooling applications; with M-Bus module
Medium: heating or chilled water
DN size: 32mm
Nominal flow (qp): 6m3/h
Length: 260mm
Connection: Flanges PN25
Media temp.: 5...105C
Max. operating pressure: 25bar
Interface: M-Bus
Interface type: Retrofittable (factory installed)


EW7731M4800

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7731M Ultrasonic hydronic meter for heating and cooling applications; with M-Bus module
Medium: heating or chilled water
DN size: 40mm
Nominal flow (qp): 10m3/h
Length: 300mm
Connection: Flanges PN25
Media temp.: 5...105C
Max. operating pressure: 25bar
Interface: M-Bus
Interface type: Retrofittable (factory installed)


EW7731M5200

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7731M Ultrasonic hydronic meter for heating and cooling applications; with M-Bus module
Medium: heating or chilled water
DN size: 50mm
Nominal flow (qp): 15m3/h
Length: 270mm
Connection: Flanges PN25
Media temp.: 5...105C
Max. operating pressure: 25bar
Interface: M-Bus
Interface type: Retrofittable (factory installed)


EW7731M6000

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7731M Ultrasonic hydronic meter for heating and cooling applications; with M-Bus module
Medium: heating or chilled water
DN size: 65mm
Nominal flow (qp): 25m3/h
Length: 300mm
Connection: Flanges PN25
Media temp.: 5...105C
Max. operating pressure: 25bar
Interface: M-Bus
Interface type: Retrofittable (factory installed)


EW7731M7000

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7731M Ultrasonic hydronic meter for heating and cooling applications; with M-Bus module
Medium: heating or chilled water
DN size: 80mm
Nominal flow (qp): 40m3/h
Length: 300mm
Connection: Flanges PN25
Media temp.: 5...105C
Max. operating pressure: 25bar
Interface: M-Bus
Interface type: Retrofittable (factory installed)


EW7731M7800

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100

Static compact hydronic meter with electronic measurement based on the ultrasonic principle, consisting of electronic energy calculator, ultrasonic flowmeter and temperature sensors.
Metering of hydronic heating and/or cooling energy in hydronic systems based on volume, supply and return temperature.
Features: Improved power efficiency
High long term stability, tested and verified by independent AGFW test
Insensitive to dirt
Versatile power supply
Optionally with integrated RF, Open Metering Standard, 868MHz
Individual remote reading (AMR) with add on plug & play modules
Measuring method: ultrasonic
Display functions: LCD, 8-digit
Power source: Standard: 3.6V A-cell lithium battery (11 year lifetime)
Optional: 3.6V D-cell lithium battery (16 year lifetime), 230Vac or 24Vac mains unit
Approvals: Approval for ultrasonic meter with dynamic range of 1:250 (qi:qp) in class 2
Approved according MID in class 2 and 3 and PTB K 7.2 (cooling)
Dynamic range: 1:250

EW7731M Ultrasonic hydronic meter for heating and cooling applications; with M-Bus module
Medium: heating or chilled water
DN size: 100mm
Nominal flow (qp): 60m3/h
Length: 360mm
Connection: Flanges PN25
Media temp.: 5...105C
Max. operating pressure: 25bar
Interface: M-Bus
Interface type: Retrofittable (factory installed)


EW9100AEZ001

Centraline EW130 Series Multijet Water Meters DN15...20
External M-Bus to RF module

For EW1300BM and EW1301BM



EW9106AFZ001

Centraline EW100 Series Singlejet Water Meters DN15...20
Clip on RF modules

Fixed network (AMR) module



EW9106AFZ002

Centraline EW100 Series Singlejet Water Meters DN15...20
Clip on RF modules

Mobile network (walk by) module



EWA087HY003

Centraline EW447, EW450 Multijet Heat Meters
Tailpiece for connection of supply temperature sensor

R1/2" external thread, M10x1 sensor thread



EWA087HY004

Centraline EW447, EW450 Multijet Heat Meters
Ballvalve with connection for supply temperature probe

G1/2" internal threads



EWA087HY005

Centraline EW447, EW450 Multijet Heat Meters
Ballvalve with connection for supply temperature probe

G3/4" internal threads



EWA087HY006

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Ball valve with connection for supply temperature probe

DN25, G1" internal threads



EWA110C1520-MBUS

Centraline EW110 Series Singlejet Water Meters DN15...40
Retrofittable clip on communication modules

Wired M-Bus clip on module for EW110, DN15-20



EWA110C1520-PO

Centraline EW110 Series Singlejet Water Meters DN15...40
Retrofittable clip on communication modules

Pulse out clip on module for EW110, DN15-20



EWA110C2540-MBUS

Centraline EW110 Series Singlejet Water Meters DN15...40
Retrofittable clip on communication modules

Wired M-Bus clip on module for EW110, DN25-40



EWA110C2540-PO

Centraline EW110 Series Singlejet Water Meters DN15...40
Retrofittable clip on communication modules

Pulse out clip on module for EW110, DN25-40



EWA120C-PO

Centraline EW120 Series Multijet Wet Dial Water Meters DN15...40
Pulse out clip on reed switch, retrofittable

For all EW120



EWA1500035

Centraline EW447, EW450 Multijet Heat Meters
Set of two union nuts, sealings and externally threaded brass tailpieces (one pack per meter required)

For DN15, thread 1/2"



EWA1500042

Centraline EW447, EW450 Multijet Heat Meters
Set of two union nuts, sealings and externally threaded brass tailpieces (one pack per meter required)

For DN20, thread 3/4"



EWA1500062

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Set of two union nuts, sealings and externally threaded brass tailpieces (one pack per meter required)

For DN25, thread 1"



EWA1500067

Centraline EW110 Series Singlejet Water Meters DN15...40
Set of two union nuts, sealings and externally threaded brass tailpieces (one pack per meter required)

For DN32, thread 1 1/4"



EWA1500072

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Set of two union nuts, sealings and externally threaded brass tailpieces (one pack per meter required)

For DN25, thread 1 1/2"



EWA171C-MBUS

Centraline EW171 Series Woltman Bulk Water Meters DN50...300
Retrofittable clip on communication modules

Wired M-Bus clip on module



EWA171C-PO

Centraline EW171 Series Woltman Bulk Water Meters DN50...300
Retrofittable clip on communication modules

Pulse out clip on module



EWA3001303

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Temperature sensor installation kit (bulk pack of 20pcs)

Brass, max. 130C



EWA3001305

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Temperature sensor installation kit (bulk pack of 20pcs)

Plastic, max. 90C



EWA3001797

Centraline EW110 Series Singlejet Water Meters DN15...40
Meter configuration

Programming interface for all pulse out modules



EWA3001799

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Bluetooth optohead

For all EW773



EWA3002684

Centraline EW447, EW450 Multijet Heat Meters
Brass immersion pockets (MID approved)

35mm, for DN15...32



EWA3002685

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Brass immersion pockets (MID approved)

52mm, for DN40...65



EWA3003095A

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Calibration certificates

For up to five meters



EWA3003095B

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Calibration certificates

For six to 20 meters



EWA3003095C

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Calibration certificates

For more than 20 meters



EWA3004406

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Brass immersion pockets (MID approved)

85mm, for DN80...125



EWA3007090

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Calculator mounts

Wall mount (single pack)



EWA3007091

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Calculator mounts

Wall mount (bulk pack of 20pcs)



EWA3022071

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Modules

M-Bus communication module (single pack)



EWA3022073

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Modules

Pulse output module with two outputs



EWA3022074

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Modules

Pulse input module with two inputs (single pack)



EWA3022075

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Modules

Combined pulse input/output module



EWA3022076

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Power supply

Mains supply unit 230V AC



EWA3022079

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Power supply

Mains supply unit 24V AC



EWA3022097

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Power supply

Replacement backup battery for mains supply units



EWA3022101

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Modules

RS485 interface module



EWA3022102

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Power supply

A-cell battery 3.6V DC (11 year lifetime) as replacement for standard battery



EWA3022103

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Power supply

D-cell battery 3.6V DC (16 year lifetime)



EWA3022106

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Modules

Analogue 4...20mA module (occupies both slots)



EWA3023125

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Modules

M-Bus communication module (bulk pack of 72pcs)



EWA3023130

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Modules

Pulse input module with two inputs (bulk pack of 72pcs)



EWA3026160

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Calculator mounts

Angle mount 105



EWA3028129

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Modules

RS232 interface module with cable



EWA354830

Centraline EW447, EW450 Multijet Heat Meters
Tailpiece for connection of supply temperature sensor

G1/4" external thread, M10x1 sensor thread



EWA54200001

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Modules and Accessories for EW773 (type 773) - former generation, built till end of 2010

M-Bus communication module (for EW773xA types)



EWA54200002

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Modules and Accessories for EW773 (type 773) - former generation, built till end of 2010

Pulse output module (2 outputs)



EWA54200003

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Modules and Accessories for EW773 (type 773) - former generation, built till end of 2010

Pulse input module (2 inputs)



EWA54200004

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Modules and Accessories for EW773 (type 773) - former generation, built till end of 2010

Mains power supply unit 230V AC



EWA54200005

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Modules and Accessories for EW773 (type 773) - former generation, built till end of 2010

Mains power supply unit 24V AC



EWA54300011

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Calculator mounts

Distance mount



EWA54300012

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
Calculator mounts

DIN rail mount



EWASET-MBUS

Centraline EW110 Series Singlejet Water Meters DN15...40
Meter configuration

EWA110C...-MBUS M-Bus module configuration software, download free of charge from http://metering.ecc.emea.honeywell.com/



EWASET-PO

Centraline EW110 Series Singlejet Water Meters DN15...40
Meter configuration

EWA110C...-PO pulse out module configuration software, download free of charge from http://metering.ecc.emea.honeywell.com/



EWP3021322

Centraline EW773 Series Ultrasonic Hydronic Meters DN15-100
IzarSet Expert dongle

For all EW773



FKA0001

Centraline E53205 - Heat cost allocator with AMR and 2-sensor Walk-By technology


Mounting prism for radiators



FKA0005

Centraline E53205 - Heat cost allocator with AMR and 2-sensor Walk-By technology


Aluminium profiles for heat cost allocators



FKK0037

Centraline E53205 - Heat cost allocator with AMR and 2-sensor Walk-By technology


Tamper for allocators - blue (package of 200 pieces)



FKT0016

Centraline E53205 - Heat cost allocator with AMR and 2-sensor Walk-By technology


50 mm adapter for mounting on vertical cast iron radiators



FKT0019

Centraline E53205 - Heat cost allocator with AMR and 2-sensor Walk-By technology


Remote sensor installation kit for panel/vertical radiators



FKT0020

Centraline E53205 - Heat cost allocator with AMR and 2-sensor Walk-By technology


70 mm adapter for mounting on vertical cast iron radiators



FT6960-18

Centraline Single-stage frost protection thermostat (FT69)

Suitable for use as frost-protection thermostats for the protection of downstream air heaters in ventilation and climate control systems as well as heat exchangers in cooling systems. Can also be used to control electrical heating systems and to switch acoustic or optical alarm signals.
Housing material: Polycarbonate and ABS
Ambient temperature: -20...55C
Switch function/capacity: SPDT 24..250 Vac, 15(8)A
Thermostat application: frost protection thermostat
Protection class: IP65


Temperature element: capillary with bulb
Capillary tube length: 1.8m
Mechanical lock/reset: manual


FT6960-30

Centraline Single-stage frost protection thermostat (FT69)

Suitable for use as frost-protection thermostats for the protection of downstream air heaters in ventilation and climate control systems as well as heat exchangers in cooling systems. Can also be used to control electrical heating systems and to switch acoustic or optical alarm signals.
Housing material: Polycarbonate and ABS
Ambient temperature: -20...55C
Switch function/capacity: SPDT 24..250 Vac, 15(8)A
Thermostat application: frost protection thermostat
Protection class: IP65


Temperature element: capillary
Capillary tube length: 3m
Mechanical lock/reset: manual


FT6960-60

Centraline Single-stage frost protection thermostat (FT69)

Suitable for use as frost-protection thermostats for the protection of downstream air heaters in ventilation and climate control systems as well as heat exchangers in cooling systems. Can also be used to control electrical heating systems and to switch acoustic or optical alarm signals.
Housing material: Polycarbonate and ABS
Ambient temperature: -20...55C
Switch function/capacity: SPDT 24..250 Vac, 15(8)A
Thermostat application: frost protection thermostat
Protection class: IP65


Temperature element: capillary
Capillary tube length: 6m
Mechanical lock/reset: manual


FT6961-18

Centraline Single-stage frost protection thermostat (FT69)

Suitable for use as frost-protection thermostats for the protection of downstream air heaters in ventilation and climate control systems as well as heat exchangers in cooling systems. Can also be used to control electrical heating systems and to switch acoustic or optical alarm signals.
Housing material: Polycarbonate and ABS
Ambient temperature: -20...55C
Switch function/capacity: SPDT 24..250 Vac, 15(8)A
Thermostat application: frost protection thermostat
Protection class: IP65


Temperature element: capillary with bulb
Capillary tube length: 1.8m
Mechanical lock/reset: automatic


FT6961-30

Centraline Single-stage frost protection thermostat (FT69)

Suitable for use as frost-protection thermostats for the protection of downstream air heaters in ventilation and climate control systems as well as heat exchangers in cooling systems. Can also be used to control electrical heating systems and to switch acoustic or optical alarm signals.
Housing material: Polycarbonate and ABS
Ambient temperature: -20...55C
Switch function/capacity: SPDT 24..250 Vac, 15(8)A
Thermostat application: frost protection thermostat
Protection class: IP65


Temperature element: capillary
Capillary tube length: 3m
Mechanical lock/reset: automatic


FT6961-60

Centraline Single-stage frost protection thermostat (FT69)

Suitable for use as frost-protection thermostats for the protection of downstream air heaters in ventilation and climate control systems as well as heat exchangers in cooling systems. Can also be used to control electrical heating systems and to switch acoustic or optical alarm signals.
Housing material: Polycarbonate and ABS
Ambient temperature: -20...55C
Switch function/capacity: SPDT 24..250 Vac, 15(8)A
Thermostat application: frost protection thermostat
Protection class: IP65


Temperature element: capillary
Capillary tube length: 6m
Mechanical lock/reset: automatic


H7012A1010

Centraline Room R.H.- and temperature sensor

Combined Room Humidity and Temperature Sensor with various sensor elements
Approvals: IEC751 class B for Pt1000 sensor
Protection class: IP30
R.H. range: 5...95%rh
R.H. sensing element: capacitive
R.H. output signal: 0..10V=
Power supply: 24Vac
Mounting place: internal wall
Housing (HxWxD): 130mm|80mm|34mm


Temperature element: no
Output signal: no
Temperature range: no


H7012B1008

Centraline Room R.H.- and temperature sensor

Combined Room Humidity and Temperature Sensor with various sensor elements
Approvals: IEC751 class B for Pt1000 sensor
Protection class: IP30
R.H. range: 5...95%rh
R.H. sensing element: capacitive
R.H. output signal: 0..10V=
Power supply: 24Vac
Mounting place: internal wall
Housing (HxWxD): 130mm|80mm|34mm


Temperature element: Pt1000
Output signal: no
Temperature range: 0...50C


H7012B1024

Centraline Room R.H.- and temperature sensor

Combined Room Humidity and Temperature Sensor with various sensor elements
Approvals: IEC751 class B for Pt1000 sensor
Protection class: IP30
R.H. range: 5...95%rh
R.H. sensing element: capacitive
R.H. output signal: 0..10V=
Power supply: 24Vac
Mounting place: internal wall
Housing (HxWxD): 130mm|80mm|34mm


Temperature element: NTC20k
Output signal: no
Temperature range: 0...50C


H7012B1030

Centraline Room R.H.- and temperature sensor

Combined Room Humidity and Temperature Sensor with various sensor elements
Approvals: IEC751 class B for Pt1000 sensor
Protection class: IP30
R.H. range: 5...95%rh
R.H. sensing element: capacitive
R.H. output signal: 0..10V=
Power supply: 24Vac
Mounting place: internal wall
Housing (HxWxD): 130mm|80mm|34mm


Temperature element: no
Output signal: temp: 0..10V=
Temperature range: 0...50C


H7015B1060

Centraline Air duct R.H.- and temperature transmitter

Protection class: IP65
Relative humidity sensor accuracy 2,5%.
Output signal: temperature: 0..10 V
relative humidity: 0..10 V
R.H. range: 0...100%rh
R.H. sensing element: capacitive
Power supply: 24Vacdc
Mounting place: air duct
Immersion depth: 235mm


Temperature range: 0...50C
Wiring terminals: 5
Note: no


H7015B1080

Centraline Air duct R.H.- and temperature transmitter

Protection class: IP65
Relative humidity sensor accuracy 2,5%.
Output signal: temperature: 0..10 V
relative humidity: 0..10 V
R.H. range: 0...100%rh
R.H. sensing element: capacitive
Power supply: 24Vacdc
Mounting place: air duct
Immersion depth: 235mm


Temperature range: -30...70C
Wiring terminals: 7
Note: extra output: NTC20k sensor


H7508B1060

Centraline Outdoor R.H.- and temperature sensor/transmitter

Protection class: IP34
Relative humidity sensor accuracy class: 3%.
Temperature range: -30...50C
R.H. range: 5...95%rh
R.H. sensing element: capacitive
R.H. output signal: 0..10V=
Power supply: 24Vacdc
Mounting place: wall outside
Housing (HxWxD): 172mm|132mm|60mm


Temperature element: no
Output signal: temp: 0..10V=
Wiring terminals: 5


H7508B1080

Centraline Outdoor R.H.- and temperature sensor/transmitter

Protection class: IP34
Relative humidity sensor accuracy class: 3%.
Temperature range: -30...50C
R.H. range: 5...95%rh
R.H. sensing element: capacitive
R.H. output signal: 0..10V=
Power supply: 24Vacdc
Mounting place: wall outside
Housing (HxWxD): 172mm|132mm|60mm


Temperature element: NTC20k
Output signal: no
Wiring terminals: 6


HCA1VEL

Centraline RF Electronic radiator controller HR92
Valve adapters

Vaillant



HCAI-K001 001

Centraline E53205 - Heat cost allocator with AMR and 2-sensor Walk-By technology


Assembly kit for steel/cast iron radiators



HCAI-K001 002

Centraline E53205 - Heat cost allocator with AMR and 2-sensor Walk-By technology


Allocator mounting set for radiators with elements with a pitch of less than 40 mm



HCAI-K001 004

Centraline E53205 - Heat cost allocator with AMR and 2-sensor Walk-By technology


Mounting kit for aluminium and cast iron radiators



HCAI-K002 001

Centraline E53205 - Heat cost allocator with AMR and 2-sensor Walk-By technology


Mounting kit for compact radiators M3x15



HCAI-K007 001

Centraline E53205 - Heat cost allocator with AMR and 2-sensor Walk-By technology


Mounting set for allocators on lamellar radiators



HCAI-K010 001

Centraline E53205 - Heat cost allocator with AMR and 2-sensor Walk-By technology


Remote sensor installation kit for convector heaters



HCAI-K010 005

Centraline E53205 - Heat cost allocator with AMR and 2-sensor Walk-By technology


Remote probe mounting kit for panel radiators



HCAI-K010-012

Centraline E53205 - Heat cost allocator with AMR and 2-sensor Walk-By technology


Remote probe mounting kit for convector heaters



HCAI-K010-0P2

Centraline E53205 - Heat cost allocator with AMR and 2-sensor Walk-By technology


Wall bracket for heat cost allocators



HCAI-K010-0S2

Centraline E53205 - Heat cost allocator with AMR and 2-sensor Walk-By technology


Remote temperature probe with 2.5 m cable suitable for Walk-By and AMR allocators (min 10 pieces)



HCC80

Centraline RF underfloor heating zone control system HCE80

Zone controller for underfloor heating with Radio Frequency bi-directional communication (868,3 MHz). The basic configuration is for 5 zones. With the submodule HCS80 expandable to 8 zones. For room temperature setpoint setting without time program apply the HCW82 wall module. For individual zoning control with time program up to 12 zones use evohome multi zoning controller ATC928G which can also control the heating system via smartphone APP.
2 push button operation
configuration switch for thermoactuators normally open/closed
error display via blinking zone LED
status display for valve open = green zone LED on
RF communication check
up to 3 controllers can be connected to 1 antenna, external HRA80 or internal antenna
Control software: self learning fuzzy logic room temperature control
Hardware inputs: connection for external antenna HRA80
heating/cooling contact
Hardware outputs: 5 outputs for max. 15 actuators (max. 3 actuators per zone) MT4-230
output for pump control
for HCE80, HCC80: analog output for boiler feedback (MCR40, MCR200, Panther, Tiger, Smile, ZG252)
for HCE80R, HCC80R: relay output (potential free contact 42 V for boiler control)
Mounting: DIN-rail or wall
Type of terminals: removable connectors with clip contact
Power supply: 230 Vac, 50Hz, 1750 VA with connected pump (max. 6 A)
http://ufh.ecc.emea.honeywell.com
ErP Class: VIII

With analog output for boiler feedback
Product description: Underfloor heating controller, with internal antenna


HCC80R

Centraline RF underfloor heating zone control system HCE80

Zone controller for underfloor heating with Radio Frequency bi-directional communication (868,3 MHz). The basic configuration is for 5 zones. With the submodule HCS80 expandable to 8 zones. For room temperature setpoint setting without time program apply the HCW82 wall module. For individual zoning control with time program up to 12 zones use evohome multi zoning controller ATC928G which can also control the heating system via smartphone APP.
2 push button operation
configuration switch for thermoactuators normally open/closed
error display via blinking zone LED
status display for valve open = green zone LED on
RF communication check
up to 3 controllers can be connected to 1 antenna, external HRA80 or internal antenna
Control software: self learning fuzzy logic room temperature control
Hardware inputs: connection for external antenna HRA80
heating/cooling contact
Hardware outputs: 5 outputs for max. 15 actuators (max. 3 actuators per zone) MT4-230
output for pump control
for HCE80, HCC80: analog output for boiler feedback (MCR40, MCR200, Panther, Tiger, Smile, ZG252)
for HCE80R, HCC80R: relay output (potential free contact 42 V for boiler control)
Mounting: DIN-rail or wall
Type of terminals: removable connectors with clip contact
Power supply: 230 Vac, 50Hz, 1750 VA with connected pump (max. 6 A)
http://ufh.ecc.emea.honeywell.com
ErP Class: VIII

With relay output
Product description: Underfloor heating controller, with internal antenna


HCE80

Centraline RF underfloor heating zone control system HCE80

Zone controller for underfloor heating with Radio Frequency bi-directional communication (868,3 MHz). The basic configuration is for 5 zones. With the submodule HCS80 expandable to 8 zones. For room temperature setpoint setting without time program apply the HCW82 wall module. For individual zoning control with time program up to 12 zones use evohome multi zoning controller ATC928G which can also control the heating system via smartphone APP.
2 push button operation
configuration switch for thermoactuators normally open/closed
error display via blinking zone LED
status display for valve open = green zone LED on
RF communication check
up to 3 controllers can be connected to 1 antenna, external HRA80 or internal antenna
Control software: self learning fuzzy logic room temperature control
Hardware inputs: connection for external antenna HRA80
heating/cooling contact
Hardware outputs: 5 outputs for max. 15 actuators (max. 3 actuators per zone) MT4-230
output for pump control
for HCE80, HCC80: analog output for boiler feedback (MCR40, MCR200, Panther, Tiger, Smile, ZG252)
for HCE80R, HCC80R: relay output (potential free contact 42 V for boiler control)
Mounting: DIN-rail or wall
Type of terminals: removable connectors with clip contact
Power supply: 230 Vac, 50Hz, 1750 VA with connected pump (max. 6 A)
http://ufh.ecc.emea.honeywell.com
ErP Class: VIII

With analog output for boiler feedback
Product description: Underfloor heating controller (apply external antenna HRA80)


HCE80R

Centraline RF underfloor heating zone control system HCE80

Zone controller for underfloor heating with Radio Frequency bi-directional communication (868,3 MHz). The basic configuration is for 5 zones. With the submodule HCS80 expandable to 8 zones. For room temperature setpoint setting without time program apply the HCW82 wall module. For individual zoning control with time program up to 12 zones use evohome multi zoning controller ATC928G which can also control the heating system via smartphone APP.
2 push button operation
configuration switch for thermoactuators normally open/closed
error display via blinking zone LED
status display for valve open = green zone LED on
RF communication check
up to 3 controllers can be connected to 1 antenna, external HRA80 or internal antenna
Control software: self learning fuzzy logic room temperature control
Hardware inputs: connection for external antenna HRA80
heating/cooling contact
Hardware outputs: 5 outputs for max. 15 actuators (max. 3 actuators per zone) MT4-230
output for pump control
for HCE80, HCC80: analog output for boiler feedback (MCR40, MCR200, Panther, Tiger, Smile, ZG252)
for HCE80R, HCC80R: relay output (potential free contact 42 V for boiler control)
Mounting: DIN-rail or wall
Type of terminals: removable connectors with clip contact
Power supply: 230 Vac, 50Hz, 1750 VA with connected pump (max. 6 A)
http://ufh.ecc.emea.honeywell.com
ErP Class: VIII

With relay output
Product description: Underfloor heating controller (apply external antenna HRA80)


HCF82

Centraline RF underfloor heating zone control system HCE80

Zone controller for underfloor heating with Radio Frequency bi-directional communication (868,3 MHz). The basic configuration is for 5 zones. With the submodule HCS80 expandable to 8 zones. For room temperature setpoint setting without time program apply the HCW82 wall module. For individual zoning control with time program up to 12 zones use evohome multi zoning controller ATC928G which can also control the heating system via smartphone APP.
2 push button operation
configuration switch for thermoactuators normally open/closed
error display via blinking zone LED
status display for valve open = green zone LED on
RF communication check
up to 3 controllers can be connected to 1 antenna, external HRA80 or internal antenna
Control software: self learning fuzzy logic room temperature control
Hardware inputs: connection for external antenna HRA80
heating/cooling contact
Hardware outputs: 5 outputs for max. 15 actuators (max. 3 actuators per zone) MT4-230
output for pump control
for HCE80, HCC80: analog output for boiler feedback (MCR40, MCR200, Panther, Tiger, Smile, ZG252)
for HCE80R, HCC80R: relay output (potential free contact 42 V for boiler control)
Mounting: DIN-rail or wall
Type of terminals: removable connectors with clip contact
Power supply: 230 Vac, 50Hz, 1750 VA with connected pump (max. 6 A)
http://ufh.ecc.emea.honeywell.com
ErP Class: VIII

Accessories
Product description: Room sensor


HCS80

Centraline RF underfloor heating zone control system HCE80

Zone controller for underfloor heating with Radio Frequency bi-directional communication (868,3 MHz). The basic configuration is for 5 zones. With the submodule HCS80 expandable to 8 zones. For room temperature setpoint setting without time program apply the HCW82 wall module. For individual zoning control with time program up to 12 zones use evohome multi zoning controller ATC928G which can also control the heating system via smartphone APP.
2 push button operation
configuration switch for thermoactuators normally open/closed
error display via blinking zone LED
status display for valve open = green zone LED on
RF communication check
up to 3 controllers can be connected to 1 antenna, external HRA80 or internal antenna
Control software: self learning fuzzy logic room temperature control
Hardware inputs: connection for external antenna HRA80
heating/cooling contact
Hardware outputs: 5 outputs for max. 15 actuators (max. 3 actuators per zone) MT4-230
output for pump control
for HCE80, HCC80: analog output for boiler feedback (MCR40, MCR200, Panther, Tiger, Smile, ZG252)
for HCE80R, HCC80R: relay output (potential free contact 42 V for boiler control)
Mounting: DIN-rail or wall
Type of terminals: removable connectors with clip contact
Power supply: 230 Vac, 50Hz, 1750 VA with connected pump (max. 6 A)
http://ufh.ecc.emea.honeywell.com
ErP Class: VIII

Accessories
Product description: Submodule for 3 additional zones


HCW82

Centraline RF underfloor heating zone control system HCE80

Zone controller for underfloor heating with Radio Frequency bi-directional communication (868,3 MHz). The basic configuration is for 5 zones. With the submodule HCS80 expandable to 8 zones. For room temperature setpoint setting without time program apply the HCW82 wall module. For individual zoning control with time program up to 12 zones use evohome multi zoning controller ATC928G which can also control the heating system via smartphone APP.
2 push button operation
configuration switch for thermoactuators normally open/closed
error display via blinking zone LED
status display for valve open = green zone LED on
RF communication check
up to 3 controllers can be connected to 1 antenna, external HRA80 or internal antenna
Control software: self learning fuzzy logic room temperature control
Hardware inputs: connection for external antenna HRA80
heating/cooling contact
Hardware outputs: 5 outputs for max. 15 actuators (max. 3 actuators per zone) MT4-230
output for pump control
for HCE80, HCC80: analog output for boiler feedback (MCR40, MCR200, Panther, Tiger, Smile, ZG252)
for HCE80R, HCC80R: relay output (potential free contact 42 V for boiler control)
Mounting: DIN-rail or wall
Type of terminals: removable connectors with clip contact
Power supply: 230 Vac, 50Hz, 1750 VA with connected pump (max. 6 A)
http://ufh.ecc.emea.honeywell.com
ErP Class: VIII

Accessories
Product description: Room sensor and setpoint adjustment


HE25

Centraline Three-way rotary valve PN10
H-extensions

H-extension DN25



HE32

Centraline Three-way rotary valve PN10
H-extensions

H-extension DN32



HGI80

Centraline evohome, colour screen multi-zone controller with remote access
Communication

Gateway Serial Interface (Tahoma Somfy)



HGK3

Centraline Air duct humidistat

Line voltage immersion humidistat for air ducts or industrial areas.
Switch function/capacity: SPDT 230 Vac, 15 A
R.H. setpoint range: 35...100%rh
R.H. hysteresis switching point: 4%rh
Ambient temperature: -30...60C
R.H. sensing element: plastic tissue
(De) Humidification application: D + H
Mounting place: air duct


HGS80

Centraline evohome, colour screen multi-zone controller with remote access
Communication

Gateway Serial Interface



HM80

Centraline evohome, colour screen multi-zone controller with remote access
Mixing valve components

Mixing valve controller



HON-NX8-KIT

Centraline Connected Building Management, HAWK 8000
HAWK 8000 Spare parts

HAWK 8000 WIFI-antenna, RS485 terminals, and power terminals



HON-NXEM-232

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000 Expansion modules
Product description: RS232 EXPANSION MODULE SINGLE PORT


HON-NXEM-2X485

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000 Expansion modules
Product description: RS385 EXPANSION MODULE DUAL PORT


HON-NXEM-LON

Centraline Connected Building Management, HAWK 8000

HAWK 8000 is a powerful hardware and software platform designed to manage HVAC and non-HVAC systems (e.g. lighting, security, life safety) in a building and across multiple buildings. It therefore supports all common communication protocols, such as BACnet, LON, Modbus, M-BUS, KNX IP, DALI, Fidelio, SNMP, C-Bus and many more. HAWK 8000 allows to make use of the CentraLine Application Library, which ensures unparalleled energy efficiency as well as maximum application reliability. This ensures that International Standards like the EN 15232 are met.
Hardware inputs/outputs
CentraLine Panel-Bus I/O modules (CLIOP)
CentraLine LON I/O modules (CLIOL)
Onboard communication inputs/outputs- Dual Ethernet 10/100Mbps: 2 RS485 ports
Optional communication inputs/outputs via expansion modules: Up to 4 RS485 ports, up to 4 RS232 ports, up to 4 LON FTT10A ports
Drivers
Included communication Drivers: BACnet/IP, BACnet MSTP, DALI, FOX, KNX, IP, LON FTT10A and IP, M-Bus, Modbus all types, oBIX, Open ADR, SNMP, Z-Wave
Included CentraLine drivers and enhancements:, Panel-Bus , C-Bus , LON IO , BACnet Integration , Project documentation and print,out , IO Creation
Optional drivers and applications
Web Server and Programming
Web Server: Supports most common mobile and PC browsers- Provides JAVA-free web-pages (HTML5)- Provides full-functional read and write access to the application, including programming
Programming: Full and web-browser based programming Option,Programming via COACH NX or COACH AX
Cyber Security
HAWK 8000 incorporates industry best practices for cyber security. This includes features such as secure boot, enforcement of strong hashed passwords, role-based access control, TLSv1 for secure communications, certificate management tools for authentication, audit log and Java-free access via web-browsers

HAWK 8000 Expansion modules
Product description: LON EXPANSION MODULE SINGLE PORT


HR92

Centraline RF Electronic radiator controller HR92

HR92 is an electronic radiator controller with a modern design. Because of the wireless communication with a frequency of 868 MHz the controller can be easily integrated in heating systems such as evohome to control the room temperature.
User-friendly
Large adjustable display with backlight.
Display of information in the display using symbols and text.
Parameters can be set individually.
Manual temperature modification (effective until the next switching point) possible at any time.
Mounting
The radiator controller fits on the most common radiator valves of the type M30x1,5.
Further adapters are available as accessories.
An external window contact can be connected optionally.
Energy saving features
With the window function, the radiator valve is closed when ventilating the room.
If an external window contact is used, the radiator valve is closed when a window is open.
Approvals: CE, RoHS
RF frequency range: 868...870MHz
RF communication distance: 30m
Temp. setpoint range: 5...35C
Frost protection temperature: 5C
Power supply: 2 batteries 1,5V: LR6, AA, AM3, Lithium or 2 rechargeable batteries 1,2 V NiMH
Housing (HxWxD): 60mm|54mm|96mm
Materials: Polycarbonat
Protection class: IP30
Ambient temperature: 0...50C
R.H. range: 10...90%rh
Built in room temperature sensor NTC
Valve connection M30x1,5

Pack containing: Controller, Base plate, Display holder, Batteries, Screws, Adapter(s)
Includes: Adapter: Danfoss RA
User panel language: German, Danish, Swedish, Finnish, Norwegian, English


HR924UK

Centraline RF Electronic radiator controller HR92

HR92 is an electronic radiator controller with a modern design. Because of the wireless communication with a frequency of 868 MHz the controller can be easily integrated in heating systems such as evohome to control the room temperature.
User-friendly
Large adjustable display with backlight.
Display of information in the display using symbols and text.
Parameters can be set individually.
Manual temperature modification (effective until the next switching point) possible at any time.
Mounting
The radiator controller fits on the most common radiator valves of the type M30x1,5.
Further adapters are available as accessories.
An external window contact can be connected optionally.
Energy saving features
With the window function, the radiator valve is closed when ventilating the room.
If an external window contact is used, the radiator valve is closed when a window is open.
Approvals: CE, RoHS
RF frequency range: 868...870MHz
RF communication distance: 30m
Temp. setpoint range: 5...35C
Frost protection temperature: 5C
Power supply: 2 batteries 1,5V: LR6, AA, AM3, Lithium or 2 rechargeable batteries 1,2 V NiMH
Housing (HxWxD): 60mm|54mm|96mm
Materials: Polycarbonat
Protection class: IP30
Ambient temperature: 0...50C
R.H. range: 10...90%rh
Built in room temperature sensor NTC
Valve connection M30x1,5

Pack containing: Controller, Base plate, Display holder, Batteries, Screws, Adapter(s)
Includes: Pack of 4 HR92UK
User panel language: English


HR924WE

Centraline RF Electronic radiator controller HR92

HR92 is an electronic radiator controller with a modern design. Because of the wireless communication with a frequency of 868 MHz the controller can be easily integrated in heating systems such as evohome to control the room temperature.
User-friendly
Large adjustable display with backlight.
Display of information in the display using symbols and text.
Parameters can be set individually.
Manual temperature modification (effective until the next switching point) possible at any time.
Mounting
The radiator controller fits on the most common radiator valves of the type M30x1,5.
Further adapters are available as accessories.
An external window contact can be connected optionally.
Energy saving features
With the window function, the radiator valve is closed when ventilating the room.
If an external window contact is used, the radiator valve is closed when a window is open.
Approvals: CE, RoHS
RF frequency range: 868...870MHz
RF communication distance: 30m
Temp. setpoint range: 5...35C
Frost protection temperature: 5C
Power supply: 2 batteries 1,5V: LR6, AA, AM3, Lithium or 2 rechargeable batteries 1,2 V NiMH
Housing (HxWxD): 60mm|54mm|96mm
Materials: Polycarbonat
Protection class: IP30
Ambient temperature: 0...50C
R.H. range: 10...90%rh
Built in room temperature sensor NTC
Valve connection M30x1,5

Pack containing: Controller, Base plate, Display holder, Batteries, Screws, Adapter(s)
Includes: Pack of 4 HR92WE
User panel language: Dutch, French, Italian, Spanish


HR92EE

Centraline RF Electronic radiator controller HR92

HR92 is an electronic radiator controller with a modern design. Because of the wireless communication with a frequency of 868 MHz the controller can be easily integrated in heating systems such as evohome to control the room temperature.
User-friendly
Large adjustable display with backlight.
Display of information in the display using symbols and text.
Parameters can be set individually.
Manual temperature modification (effective until the next switching point) possible at any time.
Mounting
The radiator controller fits on the most common radiator valves of the type M30x1,5.
Further adapters are available as accessories.
An external window contact can be connected optionally.
Energy saving features
With the window function, the radiator valve is closed when ventilating the room.
If an external window contact is used, the radiator valve is closed when a window is open.
Approvals: CE, RoHS
RF frequency range: 868...870MHz
RF communication distance: 30m
Temp. setpoint range: 5...35C
Frost protection temperature: 5C
Power supply: 2 batteries 1,5V: LR6, AA, AM3, Lithium or 2 rechargeable batteries 1,2 V NiMH
Housing (HxWxD): 60mm|54mm|96mm
Materials: Polycarbonat
Protection class: IP30
Ambient temperature: 0...50C
R.H. range: 10...90%rh
Built in room temperature sensor NTC
Valve connection M30x1,5

Pack containing: Controller, Base plate, Display holder, Batteries, Screws, Adapter(s)
Includes: Adapters: Danfoss RA, Comap/Herz M28x1,5mm
User panel language: Czech Hungarian Polish Romanian Slovak


HR92UK

Centraline RF Electronic radiator controller HR92

HR92 is an electronic radiator controller with a modern design. Because of the wireless communication with a frequency of 868 MHz the controller can be easily integrated in heating systems such as evohome to control the room temperature.
User-friendly
Large adjustable display with backlight.
Display of information in the display using symbols and text.
Parameters can be set individually.
Manual temperature modification (effective until the next switching point) possible at any time.
Mounting
The radiator controller fits on the most common radiator valves of the type M30x1,5.
Further adapters are available as accessories.
An external window contact can be connected optionally.
Energy saving features
With the window function, the radiator valve is closed when ventilating the room.
If an external window contact is used, the radiator valve is closed when a window is open.
Approvals: CE, RoHS
RF frequency range: 868...870MHz
RF communication distance: 30m
Temp. setpoint range: 5...35C
Frost protection temperature: 5C
Power supply: 2 batteries 1,5V: LR6, AA, AM3, Lithium or 2 rechargeable batteries 1,2 V NiMH
Housing (HxWxD): 60mm|54mm|96mm
Materials: Polycarbonat
Protection class: IP30
Ambient temperature: 0...50C
R.H. range: 10...90%rh
Built in room temperature sensor NTC
Valve connection M30x1,5

Pack containing: Controller, Base plate, Display holder, Batteries, Screws, Adapter(s)
Includes: Adapter: Danfoss RA
User panel language: English


HR92WE

Centraline RF Electronic radiator controller HR92

HR92 is an electronic radiator controller with a modern design. Because of the wireless communication with a frequency of 868 MHz the controller can be easily integrated in heating systems such as evohome to control the room temperature.
User-friendly
Large adjustable display with backlight.
Display of information in the display using symbols and text.
Parameters can be set individually.
Manual temperature modification (effective until the next switching point) possible at any time.
Mounting
The radiator controller fits on the most common radiator valves of the type M30x1,5.
Further adapters are available as accessories.
An external window contact can be connected optionally.
Energy saving features
With the window function, the radiator valve is closed when ventilating the room.
If an external window contact is used, the radiator valve is closed when a window is open.
Approvals: CE, RoHS
RF frequency range: 868...870MHz
RF communication distance: 30m
Temp. setpoint range: 5...35C
Frost protection temperature: 5C
Power supply: 2 batteries 1,5V: LR6, AA, AM3, Lithium or 2 rechargeable batteries 1,2 V NiMH
Housing (HxWxD): 60mm|54mm|96mm
Materials: Polycarbonat
Protection class: IP30
Ambient temperature: 0...50C
R.H. range: 10...90%rh
Built in room temperature sensor NTC
Valve connection M30x1,5

Pack containing: Controller, Base plate, Display holder, Batteries, Screws, Adapter(s)
Includes: Adapters: Danfoss RA, Comap/Herz M28x1,5mm, Caleffi
User panel language: Dutch, French, Italian, Spanish


HRA80

Centraline RF underfloor heating zone control system HCE80

Zone controller for underfloor heating with Radio Frequency bi-directional communication (868,3 MHz). The basic configuration is for 5 zones. With the submodule HCS80 expandable to 8 zones. For room temperature setpoint setting without time program apply the HCW82 wall module. For individual zoning control with time program up to 12 zones use evohome multi zoning controller ATC928G which can also control the heating system via smartphone APP.
2 push button operation
configuration switch for thermoactuators normally open/closed
error display via blinking zone LED
status display for valve open = green zone LED on
RF communication check
up to 3 controllers can be connected to 1 antenna, external HRA80 or internal antenna
Control software: self learning fuzzy logic room temperature control
Hardware inputs: connection for external antenna HRA80
heating/cooling contact
Hardware outputs: 5 outputs for max. 15 actuators (max. 3 actuators per zone) MT4-230
output for pump control
for HCE80, HCC80: analog output for boiler feedback (MCR40, MCR200, Panther, Tiger, Smile, ZG252)
for HCE80R, HCC80R: relay output (potential free contact 42 V for boiler control)
Mounting: DIN-rail or wall
Type of terminals: removable connectors with clip contact
Power supply: 230 Vac, 50Hz, 1750 VA with connected pump (max. 6 A)
http://ufh.ecc.emea.honeywell.com
ErP Class: VIII

Accessories
Product description: Active antenna for HCE80/HCE80R


HSS-DPS

Centraline Dew-point switch

This early-warning dew-point switch is designed for use in monitoring cooling water pipes or chilled surfaces in order to determine if temperatures are approaching the dewpoint. It is suitable for mounting on flat and round surfaces. The switch measures the relative humidity prevailing directly at the chilled surface and can thus be used to:
regulating cooling performance
switching cooling systems ON and OFF
signalling if the temperature is approaching the dew-point
Status indication with LED, showing condensation danger
Switching point at 90 %rh, hysteresis 5 %rh
Ambient temperature: 0...50C
Protection class: IP40
Mounting: wall, duct or pipe (max. 50 mm)
Power supply: 24Vacdc
Switch function/capacity: potential free changeover contact; max. 24 Vac/dc, 1 A
Wiring connection: 5-pole push-in terminals, max. 1,5mm2


HVAC-DOOR-KIT

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Display panel kits
Product description: SmartDrive HVAC door installation set for display panel, 3m cable
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC-FAN-4

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Main cooling fan spare parts for inverters
Product description: SmartDrive HVAC spare part fan size 4 (HVAC400-1P1..HVAC400-5P5)
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC-FAN-5

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Main cooling fan spare parts for inverters
Product description: SmartDrive HVAC spare part fan size 5 (HVAC400-7P5..HVAC400-15P)
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC-FAN-6

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Main cooling fan spare parts for inverters
Product description: SmartDrive HVAC spare part fan size 6 (HVAC400-18P..HVAC400-30P)
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC-FAN-7

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Main cooling fan spare parts for inverters
Product description: SmartDrive HVAC spare part fan size 7 (HVAC400-37P..HVAC400-55P)
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC-FAN-8

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Main cooling fan spare parts for inverters
Product description: SmartDrive HVAC spare part fan size 8 (HVAC400-75P..HVAC400-110P)
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC-FAN-9

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Main cooling fan spare parts for inverters
Product description: SmartDrive HVAC spare part fan size 9 (HVAC400-132P..HVAC400-160P)
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC-HAND-KIT

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Display panel kits
Product description: SmartDrive HVAC hand held kit for display panel, 3m cable
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC-HMI-A

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

SmartDrive HVAC display panels
Product description: SmartDrive HVAC advanced commissioning display/keypad with parameter copy function
HVAC400: yes
NXL HVAC: no
NXS: no
HVAC232/402: no


HVAC03C2

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 1.1kW
Low overload Icont: 3.3A
High overload (for Machines): 0.75kW
High overload Icont: 2.2A


HVAC03C5

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 1.1kW
Low overload Icont: 3.3A
High overload (for Machines): 0.75kW
High overload Icont: 2.2A


HVAC04C2

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 1.5kW
Low overload Icont: 4.3A
High overload (for Machines): 1.1kW
High overload Icont: 3.3A


HVAC04C5

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 1.5kW
Low overload Icont: 4.3A
High overload (for Machines): 1.1kW
High overload Icont: 3.3A


HVAC05C2

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 2.2kW
Low overload Icont: 5.6A
High overload (for Machines): 1.5kW
High overload Icont: 4.3A


HVAC05C5

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 2.2kW
Low overload Icont: 5.6A
High overload (for Machines): 1.5kW
High overload Icont: 4.3A


HVAC07C2

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 3kW
Low overload Icont: 7.6A
High overload (for Machines): 2.2kW
High overload Icont: 5.6A


HVAC07C5

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 3kW
Low overload Icont: 7.6A
High overload (for Machines): 2.2kW
High overload Icont: 5.6A


HVAC09C2

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 4kW
Low overload Icont: 9A
High overload (for Machines): 3kW
High overload Icont: 7.6A


HVAC09C5

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 4kW
Low overload Icont: 9A
High overload (for Machines): 3kW
High overload Icont: 7.6A


HVAC12C2

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 5.5kW
Low overload Icont: 12A
High overload (for Machines): 4kW
High overload Icont: 9A


HVAC12C5

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 5.5kW
Low overload Icont: 12A
High overload (for Machines): 4kW
High overload Icont: 9A


HVAC16C2

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 7.5kW
Low overload Icont: 16A
High overload (for Machines): 5.5kW
High overload Icont: 12A


HVAC16C5

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 7.5kW
Low overload Icont: 16A
High overload (for Machines): 5.5kW
High overload Icont: 12A


HVAC23C2

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 11kW
Low overload Icont: 23A
High overload (for Machines): 7.5kW
High overload Icont: 16A


HVAC23C5

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 11kW
Low overload Icont: 23A
High overload (for Machines): 7.5kW
High overload Icont: 16A


HVAC31C2

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 15kW
Low overload Icont: 31A
High overload (for Machines): 11kW
High overload Icont: 23A


HVAC31C5

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 15kW
Low overload Icont: 31A
High overload (for Machines): 11kW
High overload Icont: 23A


HVAC38C2

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 18.5kW
Low overload Icont: 38A
High overload (for Machines): 15kW
High overload Icont: 31A


HVAC38C5

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 18.5kW
Low overload Icont: 38A
High overload (for Machines): 15kW
High overload Icont: 31A


HVAC400-110-21A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 110kW
Low overload Icont: 205A
Size: 8


HVAC400-110-54A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 110kW
Low overload Icont: 205A
Size: 8


HVAC400-11P-21A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 11kW
Low overload Icont: 23A
Size: 5


HVAC400-11P-54A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 11kW
Low overload Icont: 23A
Size: 5


HVAC400-132-21A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 132kW
Low overload Icont: 261A
Size: 9


HVAC400-132-54A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 132kW
Low overload Icont: 261A
Size: 9


HVAC400-15P-21A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 15kW
Low overload Icont: 31A
Size: 5


HVAC400-15P-54A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 15kW
Low overload Icont: 31A
Size: 5


HVAC400-160-21A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 160kW
Low overload Icont: 310A
Size: 9


HVAC400-160-54A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 160kW
Low overload Icont: 310A
Size: 9


HVAC400-18P-21A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 18.5kW
Low overload Icont: 38A
Size: 6


HVAC400-18P-54A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 18.5kW
Low overload Icont: 38A
Size: 6


HVAC400-1P1-21A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 1.1kW
Low overload Icont: 3.4A
Size: 4


HVAC400-1P1-54A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 1.1kW
Low overload Icont: 3.4A
Size: 4


HVAC400-1P5-21A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 1.5kW
Low overload Icont: 4.8A
Size: 4


HVAC400-1P5-54A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 1.5kW
Low overload Icont: 4.8A
Size: 4


HVAC400-22P-21A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 22kW
Low overload Icont: 46A
Size: 6


HVAC400-22P-54A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 22kW
Low overload Icont: 46A
Size: 6


HVAC400-2P2-21A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 2.2kW
Low overload Icont: 5.6A
Size: 4


HVAC400-2P2-54A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 2.2kW
Low overload Icont: 5.6A
Size: 4


HVAC400-30P-21A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 30kW
Low overload Icont: 61A
Size: 6


HVAC400-30P-54A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 30kW
Low overload Icont: 61A
Size: 6


HVAC400-37P-21A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 37kW
Low overload Icont: 72A
Size: 7


HVAC400-37P-54A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 37kW
Low overload Icont: 72A
Size: 7


HVAC400-3P0-21A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 3kW
Low overload Icont: 8A
Size: 4


HVAC400-3P0-54A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 3kW
Low overload Icont: 8A
Size: 4


HVAC400-45P-21A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 45kW
Low overload Icont: 87A
Size: 7


HVAC400-45P-54A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 45kW
Low overload Icont: 87A
Size: 7


HVAC400-4P0-21A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 4kW
Low overload Icont: 9.6A
Size: 4


HVAC400-4P0-54A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 4kW
Low overload Icont: 9.6A
Size: 4


HVAC400-55P-21A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 55kW
Low overload Icont: 105A
Size: 7


HVAC400-55P-54A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 55kW
Low overload Icont: 105A
Size: 7


HVAC400-5P5-21A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 5.5kW
Low overload Icont: 12A
Size: 4


HVAC400-5P5-54A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 5.5kW
Low overload Icont: 12A
Size: 4


HVAC400-75P-21A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 75kW
Low overload Icont: 140A
Size: 8


HVAC400-75P-54A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 75kW
Low overload Icont: 140A
Size: 8


HVAC400-7P5-21A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 7.5kW
Low overload Icont: 16A
Size: 5


HVAC400-7P5-54A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 7.5kW
Low overload Icont: 16A
Size: 5


HVAC400-90P-21A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 90kW
Low overload Icont: 170A
Size: 8


HVAC400-90P-54A

Centraline Inverters 1,1..160kW, IP21/IP54, SmartDrive HVAC

Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant.
The SmartDrive HVAC inverters are especially designed with many advanced features for Heating, ventilation and air-conditioning applications.
Features: Detachable multilanguage HMI with advanced commissioning display/keypad (parameter copy function)
Compact size
Integrated stress removal and 360o grounding for power cable shield inside the device no need for cable glands
Varnished circuit boards as standard
Real Time Clock for timed functions and fault time stamps
Inputs/Outputs: 2 analog inputs (mA/V), 6 digital inputs, 2 relays (NO/NC), 1 thermistor input (PTC), 1 analog output (mA/V), Ethernet (IP), RS485 (MS/TP)
Flexible I/O configuration: 2 free slots for expansion boards
Start Up wizard for extremely fast start of basic pump and fan applications
Mini wizards for more advanced applications: PID, Cascade Control and Resonance sweep wizards
Intelligent automatic functionality: Ramp Time Optimizer, Overtemperature ride-through, Power ride-through etc.
PID controller with advanced features: Sleep mode, Pump Soft fill, pressure loss compensation, Cascade controller etc.
U/f control
Series: SmartDrive HVAC
RFI-filter: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Standard: BACnet IP, Modbus TCP/IP, BACnet MS/TP, Modbus RTU, N2. Optional: LonWorks
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3, category C2
EN61800-3, category C1 with optional filters Type: RFI.. (see Accessories)
EN61000-3-12
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 90kW
Low overload Icont: 170A
Size: 8


HVAC46C2

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 22kW
Low overload Icont: 46A
High overload (for Machines): 18.5kW
High overload Icont: 38A


HVAC46C5

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 22kW
Low overload Icont: 46A
High overload (for Machines): 18.5kW
High overload Icont: 38A


HVAC61C2

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21
Protection class: IP21
Low overload (for Fan/Pump): 30kW
Low overload Icont: 61A
High overload (for Machines): 22kW
High overload Icont: 46A


HVAC61C5

Centraline Inverters 1,1..30kW, IP21/IP54, NXL HVAC

Variable speed drives for induction motors, with built-in RFI filters. EMC and LVD compliant.
The inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload ratings are used. Industrial or process installations normally require High Overload ratings.
Features: the software is tailored to meet the typical HVAC application
start-up wizard
optimized I/O configuration including thermistor input
flexible I/O configuration: 2 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 thermistor input, 1 analog output
Series: NXL HVAC
RFI-filter: integrated
Brake chopper: integrated
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: Modbus RTU as standard; optional: LonWorks, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Emissions: EN61800-3 (IP21: category C2, IP54: category C1)
Safety: EN61800-5, CE, UL, cUL
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54
Protection class: IP54
Low overload (for Fan/Pump): 30kW
Low overload Icont: 61A
High overload (for Machines): 22kW
High overload Icont: 46A


HVACDOORKIT

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Display panel kits
Product description: HVAC232/402 door installation set including 2m cable and display
HVAC400: no
NXL HVAC: no
NXS: no
HVAC232/402: yes


IF-LON2

Centraline C-Bus interfaces

C-Bus Interfaces


Product description: High performance external LON-USB interface adapter. Connects a C-BUS via LON to the USB IF-LON2 interface of one of the following devices: EAGLE, EAGLEHAWK or CLIF-CBUSLC


IRA-AD

Centraline Actuator 3-pt for terminal unit/radiator, 2,5 mm 90 N, M7410A
Accessories

Adapter for Danfoss RA2000



IRM-RLC

Centraline Configurable BACnet room controller MERLIN
Cover

Terminal cover IP30 for Large housing (10 pieces)



IRM-RSC

Centraline Configurable BACnet room controller MERLIN
Cover

Terminal cover IP30 for Small housing (10 pieces)



KSW230

Centraline Electronic flow switches for liquid, compact version (KSW)

The high reliable compact electronic flow switch is designed for detecting water flow in pipes. As soon as medium flow speed exceeds or falls under a customer adjusted value, the device will switch a electric circuit.
Protection class: IP65
Switch function/capacity: SPDT, capacity 250 Vac, 10(2) A
LED's available for indication of power supply and switch status.
Immersion depth: 20mm
Media: liquid and air
Setpoint range: 0,05..3 m/s
Max. media temperature: 80C
Max. pressure: 30bar

Process connection G1/2"
Power supply: 230Vac


KSW24

Centraline Electronic flow switches for liquid, compact version (KSW)

The high reliable compact electronic flow switch is designed for detecting water flow in pipes. As soon as medium flow speed exceeds or falls under a customer adjusted value, the device will switch a electric circuit.
Protection class: IP65
Switch function/capacity: SPDT, capacity 250 Vac, 10(2) A
LED's available for indication of power supply and switch status.
Immersion depth: 20mm
Media: liquid and air
Setpoint range: 0,05..3 m/s
Max. media temperature: 80C
Max. pressure: 30bar

Process connection G1/2"
Power supply: 24Vac


KTF00-65-2M

Centraline Water temperature sensor Pt1000, cable type

Approvals: IEC751 class B
Protection class: IP65
Temperature element: Pt1000
Mounting place: universal
Immersion depth: min. 50mm
Sensing element (dia x L): 6mm|50mm


Temperature range: -30...105C
Cable length: 2m
Packing unit quantity: 1


KTF00-65-2M-300

Centraline Water temperature sensor Pt1000, cable type

Approvals: IEC751 class B
Protection class: IP65
Temperature element: Pt1000
Mounting place: universal
Immersion depth: min. 50mm
Sensing element (dia x L): 6mm|50mm


Temperature range: -20...260C
Cable length: PFTE, 2m
Packing unit quantity: 1


KTF00-65-2M-B

Centraline Water temperature sensor Pt1000, cable type

Approvals: IEC751 class B
Protection class: IP65
Temperature element: Pt1000
Mounting place: universal
Immersion depth: min. 50mm
Sensing element (dia x L): 6mm|50mm


Temperature range: -30...105C
Cable length: 2m
Packing unit quantity: 50


KTF00-65-5M-B

Centraline Water temperature sensor Pt1000, cable type

Approvals: IEC751 class B
Protection class: IP65
Temperature element: Pt1000
Mounting place: universal
Immersion depth: min. 50mm
Sensing element (dia x L): 6mm|50mm


Temperature range: -30...105C
Cable length: 5m
Packing unit quantity: 50


KTF10-65-2M

Centraline Water temperature sensor NTC, cable type

Watertight temperature sensor with sensor cartridge.
Protection class: IP65
Metal immersion spring is not included
Temperature range: -30...105C
Mounting place: universal
Immersion depth: 50mm
Sensing element (dia x L): 6mm|50mm
Wiring terminals: 2
Cable length: 2m


Temperature element: NTC10k


KTF20-65-2M

Centraline Water temperature sensor NTC, cable type

Watertight temperature sensor with sensor cartridge.
Protection class: IP65
Metal immersion spring is not included
Temperature range: -30...105C
Mounting place: universal
Immersion depth: 50mm
Sensing element (dia x L): 6mm|50mm
Wiring terminals: 2
Cable length: 2m


Temperature element: NTC20k


LAS-CLIP-25

Centraline Leakage Alarm System SeaHawk
Accessories

Cable fixations (installation fixation for both the sensing cable and the non-sensing cable (25 pieces)



LAS-NSC7

Centraline Leakage Alarm System SeaHawk
Cables

Non-sensing cable, length 7,6 meter



LAS-PSWA

Centraline Leakage Alarm System SeaHawk
Accessories

Power supply 230 V, 50 Hz / 24 Vdc



LAS-SC15

Centraline Leakage Alarm System SeaHawk
Cables

Sensing cable, length 15,2 meter



LAS-SC30

Centraline Leakage Alarm System SeaHawk
Cables

Sensing cable, length 30,4 meter



LAS-SC7

Centraline Leakage Alarm System SeaHawk
Cables

Sensing cable, length 7,6 meter



LAS-SD-Z

Centraline Leakage Alarm System SeaHawk
Spot detector

Spot detector



LAS-SH10

Centraline Leakage Alarm System SeaHawk

The SeaHawk Leakage Alarm System is a distance-read leak detection supervised system that continuously monitors a length of cable for continuity and leaks. When a cable break, contamination or leak is detected, the module calculates and annunciates the distance to the leak. This distance can then be cross-referenced with a cable reference map or immediately located by accessing an interactive map.
The SeaHawk controller can be applied for standalone operation including detection annunciation display or can be integrated into a building management system via Modbus to the Hawk controller providing a centralized source of monitoring, communication and notification capabilities.
Control software: configurable with COACH-AX software
Hardware inputs: sensing cable for water detection, length 11..3000 m
Output signal: relay SPDT contact 30 Vdc 5 A resistive, 250 Vac 8 A resistive; minimum load 10 mA 5 Vdc (signal)
audible alarm 85 dB(A) at 0,6 m
Display functions: red LED for leak alarm
yellow LED for cable contamination or fault
4-character LED display for distance or fault status
Stand-alone operation: yes
Bus system description: EIA-485, Modbus (RTU)
Mounting: DIN rail, or wall mounting with screws
Protection class: IP30
Type of terminals: screw terminals with terminal block
Power supply: 12..24 Vacdc
Housing (HxWxD): 109mm|71mm|61mm


LAS-WCCS

Centraline Leakage Alarm System SeaHawk
Accessories

Weighted cable connector (simulates 15,2 meter of sensing cable)



LF0-1B54

Centraline Air duct temperature sensor, Pt

Humidity 5..95 %rh, non condensing.
Temperature range: -40...110C
Mounting place: air duct
Wiring terminals: 2
Protection class: IP54


Temperature element: Pt100
Immersion depth: 150mm


LF00-1B54

Centraline Air duct temperature sensor, Pt

Humidity 5..95 %rh, non condensing.
Temperature range: -40...110C
Mounting place: air duct
Wiring terminals: 2
Protection class: IP54


Temperature element: Pt1000
Immersion depth: 150mm


LF00-3B54

Centraline Air duct temperature sensor, Pt

Humidity 5..95 %rh, non condensing.
Temperature range: -40...110C
Mounting place: air duct
Wiring terminals: 2
Protection class: IP54


Temperature element: Pt1000
Immersion depth: 300mm


LF10-3B54

Centraline Air duct temperature sensor, NTC

Humidity 5..95 %rh, non condensing.
Temperature range: -40...110C
Mounting place: air duct
Immersion depth: 300mm
Wiring terminals: 2


Temperature element: NTC10k
Cable length: no
Protection class: IP54


LF20-3B54

Centraline Air duct temperature sensor, NTC

Humidity 5..95 %rh, non condensing.
Temperature range: -40...110C
Mounting place: air duct
Immersion depth: 300mm
Wiring terminals: 2


Temperature element: NTC20k
Cable length: no
Protection class: IP54


LF20-3B65

Centraline Air duct temperature sensor, NTC

Humidity 5..95 %rh, non condensing.
Temperature range: -40...110C
Mounting place: air duct
Immersion depth: 300mm
Wiring terminals: 2


Temperature element: NTC20k
Cable length: no
Protection class: IP65


LF20-3P65-5M

Centraline Air duct temperature sensor, NTC

Humidity 5..95 %rh, non condensing.
Temperature range: -40...110C
Mounting place: air duct
Immersion depth: 300mm
Wiring terminals: 2


Temperature element: NTC20k
Cable length: 5m
Protection class: IP65


LSU25-18

Centraline Three-way rotary valve PN10
Accessories

Soldering socket witch gasket and cap nut, DN25, pipe size 18 mm



LSU25-22

Centraline Three-way rotary valve PN10
Accessories

Soldering socket witch gasket and cap nut, DN25, pipe size 22 mm



LSU25-28

Centraline Three-way rotary valve PN10
Accessories

Soldering socket witch gasket and cap nut, DN25, pipe size 28 mm



LSU32-22

Centraline Three-way rotary valve PN10
Accessories

Soldering socket witch gasket and cap nut, DN32, pipe size 22 mm



LSU32-28

Centraline Three-way rotary valve PN10
Accessories

Soldering socket witch gasket and cap nut, DN32, pipe size 28 mm



LSU32-35

Centraline Three-way rotary valve PN10
Accessories

Soldering socket witch gasket and cap nut, DN32, pipe size 35 mm



M44-MOD-1M

Centraline Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410
Required Cable (old cable of MT010 actuators can also be used)

Cable with plug, 1 meter, 3 x 0,22 mm2 (10 pieces)



M44-MOD-1M/U

Centraline Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410
Required Cable (old cable of MT010 actuators can also be used)

Cable with plug, 1 meter, 3 x 0,22 mm2 (1 piece)



M44-MOD-1MH

Centraline Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410
Required Cable (old cable of MT010 actuators can also be used)

Non-halogen cable with plug, 1 meter, 3 x 0,22 mm2 (10 pieces)



M44-MOD-1MH/U

Centraline Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410
Required Cable (old cable of MT010 actuators can also be used)

Non-halogen cable with plug, 1 meter, 3 x 0,22 mm2 (1 piece)



M44-MOD-3M

Centraline Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410
Required Cable (old cable of MT010 actuators can also be used)

Cable with plug, 3 meter, 3 x 0,22 mm2 (10 pieces)



M44-MOD-3MH

Centraline Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410
Required Cable (old cable of MT010 actuators can also be used)

Non-halogen cable with plug, 3 meter, 3 x 0,22 mm2 (10 pieces)



M44-MOD-5M

Centraline Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410
Required Cable (old cable of MT010 actuators can also be used)

Cable with plug, 5 meter, 3 x 0,22 mm2 (10 pieces)



M44-MOD-5MH

Centraline Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410
Required Cable (old cable of MT010 actuators can also be used)

Non-halogen cable with plug, 5 meter, 3 x 0,22 mm2 (10 pieces)



M44-VA10

Centraline Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410
Valve Adapters M30 x 1,5

Valve adapter with closing dimension 11,5mm (10 pieces)



M44-VA50

Centraline Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410
Valve Adapters M30 x 1,5

Valve adapter with closing dimension 10,5mm (10 pieces)



M4410E1510

Centraline Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410

Electrical actuator for (radiator) valves with connection size M30 x 1,5. The actuator is supplied with the M44-VA10 adapter (closing dimension 11,5 mm). This suits the following valves:
V58xxA4, V58xxC4, VSO
V300, V2000
V2464, V2474
A separate adapter can be ordered (M44-VA50). With this adapter the actuator fits to the valves with closing dimension 10,5 mm.
Protection class: IP54
Effective stroke for Honeywell valves 2,5 mm; maximum stroke 4 mm.
Stem force: 100N
Control input signal: 0..10V=
Stroke: 2.5mm
Power loss action: stem extends
Runtime: 75s
Cable length: optional: 1, 3 ,5m
Required materials: check accessories

2,5 mm; 100 N
Supply voltage: 24 Vac


M4410K1515

Centraline Actuator thermoelectric 0..10V for radiator/terminal units, 2,5 mm 100 N, M4410

Electrical actuator for (radiator) valves with connection size M30 x 1,5. The actuator is supplied with the M44-VA10 adapter (closing dimension 11,5 mm). This suits the following valves:
V58xxA4, V58xxC4, VSO
V300, V2000
V2464, V2474
A separate adapter can be ordered (M44-VA50). With this adapter the actuator fits to the valves with closing dimension 10,5 mm.
Protection class: IP54
Effective stroke for Honeywell valves 2,5 mm; maximum stroke 4 mm.
Stem force: 100N
Control input signal: 0..10V=
Stroke: 2.5mm
Power loss action: stem extends
Runtime: 75s
Cable length: optional: 1, 3 ,5m
Required materials: check accessories

2,5 mm; 100 N
Supply voltage: 24 Vdc


M5410C1001

Centraline Fast motoric actuator for terminal unit/radiator, 6,5 mm 90 N, M5410

Electrical actuator on/off control, for valve series VS, V58.. DN15/20 and V100/V2000 TRV-series.
Protection class: IP54
Manual operation with valve cap.
Stem force: 90N
Control input signal: 2-pt
Stroke: 6.5mm
Power loss action: stem retracts
Runtime: 3,6/16s
Cable length: 1.5m

6,5 mm; 90 N
Supply voltage: 24 Vac/dc


M5410L1001

Centraline Fast motoric actuator for terminal unit/radiator, 6,5 mm 90 N, M5410

Electrical actuator on/off control, for valve series VS, V58.. DN15/20 and V100/V2000 TRV-series.
Protection class: IP54
Manual operation with valve cap.
Stem force: 90N
Control input signal: 2-pt
Stroke: 6.5mm
Power loss action: stem retracts
Runtime: 3,6/16s
Cable length: 1.5m

6,5 mm; 90 N
Supply voltage: 230 Vac


M6061A1013

Centraline Standard Line Rotary Actuator

Electrical actuator for valve series VBG (DN40..DN50)
Protection class: IP54
Position indication: reversable scale plate
Manual operation by declutch of gear.
Angle of rotation: 90o
Manual operation: yes

Floating control
Torque: 10Nm
Supply voltage: 24 Vac
Control input signal: 3-pt
Runtime: 1.5min
Position feedback: no
End switches: optional


M6061A1021

Centraline Standard Line Rotary Actuator

Electrical actuator for valve series VBG (DN40..DN50)
Protection class: IP54
Position indication: reversable scale plate
Manual operation by declutch of gear.
Angle of rotation: 90o
Manual operation: yes

Floating control
Torque: 20Nm
Supply voltage: 24 Vac
Control input signal: 3-pt
Runtime: 1.6min
Position feedback: no
End switches: optional


M6061A1039

Centraline Standard Line Rotary Actuator

Electrical actuator for valve series VBG (DN40..DN50)
Protection class: IP54
Position indication: reversable scale plate
Manual operation by declutch of gear.
Angle of rotation: 90o
Manual operation: yes

Floating control
Torque: 30Nm
Supply voltage: 24 Vac
Control input signal: 3-pt
Runtime: 2.3min
Position feedback: no
End switches: optional


M6061A1047

Centraline Standard Line Rotary Actuator

Electrical actuator for valve series VBG (DN40..DN50)
Protection class: IP54
Position indication: reversable scale plate
Manual operation by declutch of gear.
Angle of rotation: 90o
Manual operation: yes

Floating control
Torque: 40Nm
Supply voltage: 24 Vac
Control input signal: 3-pt
Runtime: 3.5min
Position feedback: no
End switches: optional


M6061L1019

Centraline Standard Line Rotary Actuator

Electrical actuator for valve series VBG (DN40..DN50)
Protection class: IP54
Position indication: reversable scale plate
Manual operation by declutch of gear.
Angle of rotation: 90o
Manual operation: yes

Floating control
Torque: 10Nm
Supply voltage: 230 Vac
Control input signal: 3-pt
Runtime: 1.5min
Position feedback: no
End switches: optional


M6061L1027

Centraline Standard Line Rotary Actuator

Electrical actuator for valve series VBG (DN40..DN50)
Protection class: IP54
Position indication: reversable scale plate
Manual operation by declutch of gear.
Angle of rotation: 90o
Manual operation: yes

Floating control
Torque: 20Nm
Supply voltage: 230 Vac
Control input signal: 3-pt
Runtime: 1.6min
Position feedback: no
End switches: optional


M6061L1035

Centraline Standard Line Rotary Actuator

Electrical actuator for valve series VBG (DN40..DN50)
Protection class: IP54
Position indication: reversable scale plate
Manual operation by declutch of gear.
Angle of rotation: 90o
Manual operation: yes

Floating control
Torque: 30Nm
Supply voltage: 230 Vac
Control input signal: 3-pt
Runtime: 2.3min
Position feedback: optional
End switches: optional


M6061L1043

Centraline Standard Line Rotary Actuator

Electrical actuator for valve series VBG (DN40..DN50)
Protection class: IP54
Position indication: reversable scale plate
Manual operation by declutch of gear.
Angle of rotation: 90o
Manual operation: yes

Floating control
Torque: 40Nm
Supply voltage: 230 Vac
Control input signal: 3-pt
Runtime: 3.5min
Position feedback: no
End switches: optional


M6063A1003

Centraline Compact Line Rotary Actuator

Electrical actuator for valve series V5433A/G, V5442A/G.
Protection class: IP44
End switch function/capacity: SPST; capacity 1A inductive, 3 A resistive
Manual operation by declutch of gear.
Torque: 7Nm
Control input signal: 3-pt
Angle of rotation: 90o
Manual operation: yes
Runtime: 100s
Cable length: 1.5m


Supply voltage: 24 Vac
End switches: no


M6063A4007

Centraline Compact Line Rotary Actuator

Electrical actuator for valve series V5433A/G, V5442A/G.
Protection class: IP44
End switch function/capacity: SPST; capacity 1A inductive, 3 A resistive
Manual operation by declutch of gear.
Torque: 7Nm
Control input signal: 3-pt
Angle of rotation: 90o
Manual operation: yes
Runtime: 100s
Cable length: 1.5m


Supply voltage: 24 Vac
End switches: 2


M6063L1009

Centraline Compact Line Rotary Actuator

Electrical actuator for valve series V5433A/G, V5442A/G.
Protection class: IP44
End switch function/capacity: SPST; capacity 1A inductive, 3 A resistive
Manual operation by declutch of gear.
Torque: 7Nm
Control input signal: 3-pt
Angle of rotation: 90o
Manual operation: yes
Runtime: 100s
Cable length: 1.5m


Supply voltage: 230 Vac
End switches: no


M6063L4003

Centraline Compact Line Rotary Actuator

Electrical actuator for valve series V5433A/G, V5442A/G.
Protection class: IP44
End switch function/capacity: SPST; capacity 1A inductive, 3 A resistive
Manual operation by declutch of gear.
Torque: 7Nm
Control input signal: 3-pt
Angle of rotation: 90o
Manual operation: yes
Runtime: 100s
Cable length: 1.5m


Supply voltage: 230 Vac
End switches: 2


M6410C2023

Centraline Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM
Stem force: 180N
Supply voltage: 24 Vac
Manual operation: yes
End switches: no
Cable length: 1.5m


M6410C2031

Centraline Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 300 N; for valve series: V5825B, V5832B2, V5833A2
Stem force: 300N
Supply voltage: 24 Vac
Manual operation: yes
End switches: no
Cable length: 1.5m


M6410C4029

Centraline Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM
Stem force: 180N
Supply voltage: 24 Vac
Manual operation: yes
End switches: 2
Cable length: 1.5m


M6410C4037

Centraline Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 300 N; for valve series: V5825B, V5832B2, V5833A2
Stem force: 300N
Supply voltage: 24 Vac
Manual operation: yes
End switches: 2
Cable length: 1.5m


M6410L2023

Centraline Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM
Stem force: 180N
Supply voltage: 230 Vac
Manual operation: yes
End switches: no
Cable length: 1.5m


M6410L2031

Centraline Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 300 N; for valve series: V5825B, V5832B2, V5833A2
Stem force: 300N
Supply voltage: 230 Vac
Manual operation: yes
End switches: no
Cable length: 1.5m


M6410L4029

Centraline Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM
Stem force: 180N
Supply voltage: 230 Vac
Manual operation: yes
End switches: 2
Cable length: 1.5m


M6410L4037

Centraline Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 300 N; for valve series: V5825B, V5832B2, V5833A2
Stem force: 300N
Supply voltage: 230 Vac
Manual operation: yes
End switches: 2
Cable length: 1.5m


M6422L1003

Centraline Actuator for V5421B1090

Protection class: IP54
Supply voltage: 230 Vac
Control input signal: 3-pt
Built in rotation limiter: no
Manual operation: yes
End switches: optional
Runtime: 150s
Torque: 40Nm


M7061E1012

Centraline Standard Line Rotary Actuator

Electrical actuator for valve series VBG (DN40..DN50)
Protection class: IP54
Position indication: reversable scale plate
Manual operation by declutch of gear.
Angle of rotation: 90o
Manual operation: yes

Modulating control
Torque: 10Nm
Supply voltage: 24 Vac/dc
Control input signal: 0/2..10V=
Runtime: 1.5min
Position feedback: optional
End switches: no


M7061E1020

Centraline Standard Line Rotary Actuator

Electrical actuator for valve series VBG (DN40..DN50)
Protection class: IP54
Position indication: reversable scale plate
Manual operation by declutch of gear.
Angle of rotation: 90o
Manual operation: yes

Modulating control
Torque: 20Nm
Supply voltage: 24 Vac/dc
Control input signal: 0/2..10V=
Runtime: 3.0min
Position feedback: optional
End switches: no


M7410A1001

Centraline Actuator 3-pt for terminal unit/radiator, 2,5 mm 90 N, M7410A

Electrical actuator floating control, for valve series: V135, V136, V58..A4, V58..C4, VSO.
Protection class: IP43
Position indication: with red indicator
Manual operation with valve cap.
Supply voltage: 24 Vac
Stem force: 90N
Control input signal: 3-pt
Stroke: 2.5mm
Runtime: 57s

2,5 mm; 90 N
Cable length: 0.9m


M7410A1001-3M

Centraline Actuator 3-pt for terminal unit/radiator, 2,5 mm 90 N, M7410A

Electrical actuator floating control, for valve series: V135, V136, V58..A4, V58..C4, VSO.
Protection class: IP43
Position indication: with red indicator
Manual operation with valve cap.
Supply voltage: 24 Vac
Stem force: 90N
Control input signal: 3-pt
Stroke: 2.5mm
Runtime: 57s

2,5 mm; 90 N
Cable length: 3m


M7410C1007

Centraline Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM
Stem force: 180N
Supply voltage: 24 Vac
Manual operation: no
End switches: no
Cable length: 1.5m


M7410C1007-10M

Centraline Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM
Stem force: 180N
Supply voltage: 24 Vac
Manual operation: no
End switches: no
Cable length: 10m


M7410C1015

Centraline Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410

Electrical actuator floating control.
Protection class: IP43/IP42
Position indication: with red indicator
End switch function/capacity: SPDT; capacity 1 A inductive, 5 A resistive
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Control input signal: 3-pt
Stroke: 6.5mm
Runtime: 150s

6,5 mm; 300 N; for valve series: V5825B, V5832B2, V5833A2
Stem force: 300N
Supply voltage: 24 Vac
Manual operation: no
End switches: no
Cable length: 1.5m


M7410E1002

Centraline Actuator 0/2..10V for zone control, 90/180/300 N, M7410E

Electrical actuator modulating control.
Protection class: IP42
Position indication: with red indicator
End switch function/capacity: SPDT, capacity 1A inductive, 5A resistive
The control action is reversable. For M7410E1..-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Supply voltage: 24 Vac
Control input signal: 0/2..10V=
Cable length: 1.5m

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM
Stem force: 180N
Stroke: 6.5mm
Manual operation: no
End switches: no
Runtime: 150s


M7410E1028

Centraline Actuator 0/2..10V for zone control, 90/180/300 N, M7410E

Electrical actuator modulating control.
Protection class: IP42
Position indication: with red indicator
End switch function/capacity: SPDT, capacity 1A inductive, 5A resistive
The control action is reversable. For M7410E1..-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Supply voltage: 24 Vac
Control input signal: 0/2..10V=
Cable length: 1.5m

6,5 mm; 300 N; for valve series: V5825B, V5832B2, V5833A2
Stem force: 300N
Stroke: 6.5mm
Manual operation: no
End switches: no
Runtime: 150s


M7410E2026

Centraline Actuator 0/2..10V for zone control, 90/180/300 N, M7410E

Electrical actuator modulating control.
Protection class: IP42
Position indication: with red indicator
End switch function/capacity: SPDT, capacity 1A inductive, 5A resistive
The control action is reversable. For M7410E1..-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Supply voltage: 24 Vac
Control input signal: 0/2..10V=
Cable length: 1.5m

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM
Stem force: 180N
Stroke: 6.5mm
Manual operation: yes
End switches: no
Runtime: 150s


M7410E2034

Centraline Actuator 0/2..10V for zone control, 90/180/300 N, M7410E

Electrical actuator modulating control.
Protection class: IP42
Position indication: with red indicator
End switch function/capacity: SPDT, capacity 1A inductive, 5A resistive
The control action is reversable. For M7410E1..-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Supply voltage: 24 Vac
Control input signal: 0/2..10V=
Cable length: 1.5m

6,5 mm; 300 N; for valve series: V5825B, V5832B2, V5833A2
Stem force: 300N
Stroke: 6.5mm
Manual operation: yes
End switches: no
Runtime: 150s


M7410E4022

Centraline Actuator 0/2..10V for zone control, 90/180/300 N, M7410E

Electrical actuator modulating control.
Protection class: IP42
Position indication: with red indicator
End switch function/capacity: SPDT, capacity 1A inductive, 5A resistive
The control action is reversable. For M7410E1..-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Supply voltage: 24 Vac
Control input signal: 0/2..10V=
Cable length: 1.5m

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM
Stem force: 180N
Stroke: 6.5mm
Manual operation: yes
End switches: 2
Runtime: 150s


M7410E4030

Centraline Actuator 0/2..10V for zone control, 90/180/300 N, M7410E

Electrical actuator modulating control.
Protection class: IP42
Position indication: with red indicator
End switch function/capacity: SPDT, capacity 1A inductive, 5A resistive
The control action is reversable. For M7410E1..-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Supply voltage: 24 Vac
Control input signal: 0/2..10V=
Cable length: 1.5m

6,5 mm; 300 N; for valve series: V5825B, V5832B2, V5833A2
Stem force: 300N
Stroke: 6.5mm
Manual operation: yes
End switches: 2
Runtime: 150s


M7410E5001

Centraline Actuator 0/2..10V for zone control, 90/180/300 N, M7410E

Electrical actuator modulating control.
Protection class: IP42
Position indication: with red indicator
End switch function/capacity: SPDT, capacity 1A inductive, 5A resistive
The control action is reversable. For M7410E1..-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
Supply voltage: 24 Vac
Control input signal: 0/2..10V=
Cable length: 1.5m

2,7 mm; 90 N; for valve series V5004TY. 2,5 mm; 90 N; for valve series V5822A, V5823A/C, V5832A, V5833A/C, VSO and TRV V20/V30
Stem force: 90N
Stroke: 2.5mm
Manual operation: no
End switches: no
Runtime: 70s


M7410G1008

Centraline LON actuator for radiator/zone control, 2,5/6,5 mm 90/180/300 N, M7410G

Electrical actuator with LON input signal.
Protection class: IP42
Position indication: with red indicator
LonMark(R) profile: input SNVT percent 0-100%
Transceiver type: FTT 10A
Contact input available for override function fully open or closed. Manual operation with valve cap. Configurable parameters for direct/reverse acting. LED-indication for servicing.
Supply voltage: 24 Vac
Control input signal: LON
Cable length: 1.5m

2,5 mm; 90 N; for valve series: V100 (thermostatic valves), V58..A4, V58..C4, VSO
Stem force: 90N
Stroke: 2.5mm
Runtime: 53s


M7410G1016

Centraline LON actuator for radiator/zone control, 2,5/6,5 mm 90/180/300 N, M7410G

Electrical actuator with LON input signal.
Protection class: IP42
Position indication: with red indicator
LonMark(R) profile: input SNVT percent 0-100%
Transceiver type: FTT 10A
Contact input available for override function fully open or closed. Manual operation with valve cap. Configurable parameters for direct/reverse acting. LED-indication for servicing.
Supply voltage: 24 Vac
Control input signal: LON
Cable length: 1.5m

6,5 mm; 180 N; for valve series: V5078B, V5822A, V5823A/C, V5832A, V5833A/C, VSM
Stem force: 180N
Stroke: 6.5mm
Runtime: 150s


M7410G1024

Centraline LON actuator for radiator/zone control, 2,5/6,5 mm 90/180/300 N, M7410G

Electrical actuator with LON input signal.
Protection class: IP42
Position indication: with red indicator
LonMark(R) profile: input SNVT percent 0-100%
Transceiver type: FTT 10A
Contact input available for override function fully open or closed. Manual operation with valve cap. Configurable parameters for direct/reverse acting. LED-indication for servicing.
Supply voltage: 24 Vac
Control input signal: LON
Cable length: 1.5m

6,5 mm; 300 N; for valve series: V5825B, V5832B2, V5833A2
Stem force: 300N
Stroke: 6.5mm
Runtime: 150s


MCD3

Centraline Relay module for on/off and 3-pt control

Two channel signal converter module.
For a signal change from 0..10Vdc (from external controller) into on/off and 3-pt control relay contact output.
Input signal: 2 x 0..10 Vdc
Output signal: relay K1 and K2 SPST contact 240V 0,2 A supplying 3-pt control of first analogue input
relay K3 SPDT contact 240V 2 A, supplying on/off control of second analogue input
Mounting: DIN rail
Power supply: 24Vacdc


MCE1

Centraline Voltage level switch

For conversion of an analogue output signal from a controller into an on/off output signal.
Input signal: 0..10 Vdc
Output signal: relay contact SPDT 250 V, 4 A; relay on with input voltage > 3 V, relay off with input voltage < 2,5 V
Manual operation functions: override switch with auto-off-on position
LED functions: yellow LED showing relay status
Mounting: DIN rail
Power supply: 24Vacdc


MCE2

Centraline Conversion module 24Vdc/relay

For conversion of an 24 Vdc signal from a digital output of a controller into an on/off output signal.
Input signal: 0 or 24 Vdc
Output signal: relay contact SPDT 250 V, 6 A; relay on with 24 V, off with 0 V input signal
Manual operation functions: override switch with auto-off-on position
LED functions: yellow LED showing relay status
Mounting: DIN rail
Power supply: 24Vacdc


MCE3

Centraline Conversion module 0..10Vdc - relay, 3 channel

Three channel signal converter module.
For a signal change from 0..10Vdc (from external controller) into an on/off relay contact output.
Input signal: 3x 0..10 Vdc
Output signal: relay K1/K2 SPDT contact 240 V, 2 A
relay K3 SPST contact 240 V, 2 A
Mounting: DIN rail
Power supply: 24Vacdc


MCM1

Centraline Status display module, 4 channel

Status indication module for external contacts.
Input signal: 4 x external potential free contacts
Output signal: 4 x 24Vacdc (from power supply)
Manual operation functions: 4 x switch for LED status inversion
LED functions: 4 x red or green LED showing the status of the input
Mounting: DIN rail
Power supply: 24Vacdc


MCP1

Centraline Manual positioning module

Manual positioning module for analogue output signals to manually adjust damper and valve actuators or to provide a fixed position.
Input signal: 0..10 Vdc
Output signal: 0..10 Vdc from input or from potentiometer (max. 1 mA)
Manual operation functions: potentiometer to adjust output signal 0..10Vdc; switch with auto/manual position
LED functions: red LED, intensity shows output level
Mounting: DIN rail
Potential free contact for feedback of manual override.
Power supply: 24Vacdc


ML6420A3007

Centraline Actuator 3-pt, 20 mm 600 N, ML6420/ML6425

Electrical actuator floating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Position feedback: optional
End switches: optional
For ML6425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Stem force: 600N
Control input signal: 3-pt
Stroke: 20mm

20 mm; 600 N
Supply voltage: 24 Vac
Power loss action: no
Manual operation: yes
Runtime: 1.0min
Spring return: no


ML6420A3015

Centraline Actuator 3-pt, 20 mm 600 N, ML6420/ML6425

Electrical actuator floating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Position feedback: optional
End switches: optional
For ML6425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Stem force: 600N
Control input signal: 3-pt
Stroke: 20mm

20 mm; 600 N
Supply voltage: 230 Vac
Power loss action: no
Manual operation: yes
Runtime: 1.0min
Spring return: no


ML6420A3023

Centraline Actuator 3-pt, 20 mm 600 N, ML6420/ML6425

Electrical actuator floating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Position feedback: optional
End switches: optional
For ML6425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Stem force: 600N
Control input signal: 3-pt
Stroke: 20mm

20 mm; 600 N
Supply voltage: 24 Vac
Power loss action: no
Manual operation: yes
Runtime: 0.5min
Spring return: no


ML6420A3031

Centraline Actuator 3-pt, 20 mm 600 N, ML6420/ML6425

Electrical actuator floating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Position feedback: optional
End switches: optional
For ML6425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Stem force: 600N
Control input signal: 3-pt
Stroke: 20mm

20 mm; 600 N
Supply voltage: 230 Vac
Power loss action: no
Manual operation: yes
Runtime: 0.5min
Spring return: no


ML6420A3072

Centraline Actuator 3-pt, 20 mm 600 N, ML6420/ML6425

Electrical actuator floating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Position feedback: optional
End switches: optional
For ML6425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Stem force: 600N
Control input signal: 3-pt
Stroke: 20mm

20 mm; 600 N
Supply voltage: 24 Vac
Power loss action: no
Manual operation: no
Runtime: 1.0min
Spring return: no


ML6421A3005

Centraline Actuator 3-pt, 20/38 mm 1800 N, ML6421

Electrical actuator floating control, for valve series: V5011, V5013, V5015, V5016, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate on the yoke
End switches: optional
Stem force: 1800N
Control input signal: 3-pt
Manual operation: yes

20 mm; 1800 N
Supply voltage: 24 Vac
Stroke: 20mm
Runtime: 1.9min
Position feedback: optional


ML6421A3013

Centraline Actuator 3-pt, 20/38 mm 1800 N, ML6421

Electrical actuator floating control, for valve series: V5011, V5013, V5015, V5016, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate on the yoke
End switches: optional
Stem force: 1800N
Control input signal: 3-pt
Manual operation: yes

20 mm; 1800 N
Supply voltage: 230 Vac
Stroke: 20mm
Runtime: 1.9min
Position feedback: no


ML6421B3004

Centraline Actuator 3-pt, 20/38 mm 1800 N, ML6421

Electrical actuator floating control, for valve series: V5011, V5013, V5015, V5016, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate on the yoke
End switches: optional
Stem force: 1800N
Control input signal: 3-pt
Manual operation: yes

38 mm; 1800 N
Supply voltage: 24 Vac
Stroke: 38mm
Runtime: 3.5min
Position feedback: optional


ML6421B3012

Centraline Actuator 3-pt, 20/38 mm 1800 N, ML6421

Electrical actuator floating control, for valve series: V5011, V5013, V5015, V5016, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate on the yoke
End switches: optional
Stem force: 1800N
Control input signal: 3-pt
Manual operation: yes

38 mm; 1800 N
Supply voltage: 230 Vac
Stroke: 38mm
Runtime: 3.5min
Position feedback: no


ML6425A3006

Centraline Actuator 3-pt, 20 mm 600 N, ML6420/ML6425

Electrical actuator floating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Position feedback: optional
End switches: optional
For ML6425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Stem force: 600N
Control input signal: 3-pt
Stroke: 20mm

20 mm; 600 N, Spring return
Supply voltage: 24 Vac
Power loss action: stem extends
Manual operation: no
Runtime: 1.8min
Spring return: yes


ML6425A3014

Centraline Actuator 3-pt, 20 mm 600 N, ML6420/ML6425

Electrical actuator floating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Position feedback: optional
End switches: optional
For ML6425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Stem force: 600N
Control input signal: 3-pt
Stroke: 20mm

20 mm; 600 N, Spring return
Supply voltage: 230 Vac
Power loss action: stem extends
Manual operation: no
Runtime: 1.8min
Spring return: yes


ML6425B3005

Centraline Actuator 3-pt, 20 mm 600 N, ML6420/ML6425

Electrical actuator floating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Position feedback: optional
End switches: optional
For ML6425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Stem force: 600N
Control input signal: 3-pt
Stroke: 20mm

20 mm; 600 N, Spring return
Supply voltage: 24 Vac
Power loss action: stem retracts
Manual operation: no
Runtime: 1.8min
Spring return: yes


ML6425B3021

Centraline Actuator 3-pt, 20 mm 600 N, ML6420/ML6425

Electrical actuator floating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Position feedback: optional
End switches: optional
For ML6425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Stem force: 600N
Control input signal: 3-pt
Stroke: 20mm

20 mm; 600 N, Spring return
Supply voltage: 230 Vac
Power loss action: stem retracts
Manual operation: no
Runtime: 1.8min
Spring return: yes


ML6435B1008

Centraline Actuator 3-pt for district heating, DHWS, spring return, 6,5 mm 400 N, ML6435

Electrical actuator floating control, for valve series: V5825B. Also suitable for V5832B/V5833A-series (DN25..40)
Protection class: IP54
Approved according DIN EN 14597 in combination with V5825B.
Stem force: 400N
Control input signal: 3-pt
Stroke: 6.5mm
Power loss action: stem retracts
Runtime: 60s
Spring return: yes

6,5 mm; 400 N
Supply voltage: 24 Vac


ML6435B1016

Centraline Actuator 3-pt for district heating, DHWS, spring return, 6,5 mm 400 N, ML6435

Electrical actuator floating control, for valve series: V5825B. Also suitable for V5832B/V5833A-series (DN25..40)
Protection class: IP54
Approved according DIN EN 14597 in combination with V5825B.
Stem force: 400N
Control input signal: 3-pt
Stroke: 6.5mm
Power loss action: stem retracts
Runtime: 60s
Spring return: yes

6,5 mm; 400 N
Supply voltage: 230 Vac


ML7420A6009

Centraline Actuator 0/2..10V, 20 mm 600 N, ML7420/ML7425

Electrical actuator modulating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Stem position at control signal loss: adjustable
End switches: optional
The control action is reversable. For ML7425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Supply voltage: 24 Vac
Stem force: 600N
Stroke: 20mm

20 mm; 600 N
Control input signal: 0/2..10V=
Power loss action: no
Manual operation: yes
Runtime: 1.0min
Spring return: no
Position feedback: 2..10V=


ML7420A6017

Centraline Actuator 0/2..10V, 20 mm 600 N, ML7420/ML7425

Electrical actuator modulating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Stem position at control signal loss: adjustable
End switches: optional
The control action is reversable. For ML7425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Supply voltage: 24 Vac
Stem force: 600N
Stroke: 20mm

20 mm; 600 N
Control input signal: 0/2..10V=
Power loss action: no
Manual operation: yes
Runtime: 0.5min
Spring return: no
Position feedback: 2..10V=


ML7420A6025

Centraline Actuator 0/2..10V, 20 mm 600 N, ML7420/ML7425

Electrical actuator modulating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Stem position at control signal loss: adjustable
End switches: optional
The control action is reversable. For ML7425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Supply voltage: 24 Vac
Stem force: 600N
Stroke: 20mm

20 mm; 600 N
Control input signal: 2..10V=
Power loss action: no
Manual operation: no
Runtime: 1.0min
Spring return: no
Position feedback: no


ML7421A3004

Centraline Actuator 0/2..10V, 20/38 mm 1800 N, ML7421

Electrical actuator modulating control, for valve series: V5011, V5013, V5015, V5016, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Stem position at control signal loss: selectable: closed, half open, open
Position feedback: 2..10V=
End switches: optional
Supply voltage: 24 Vac
Stem force: 1800N
Control input signal: 0/2..10V=; 0/4..20mA
Manual operation: yes

20 mm; 1800 N
Stroke: 20mm
Runtime: 1.9min


ML7421B3003

Centraline Actuator 0/2..10V, 20/38 mm 1800 N, ML7421

Electrical actuator modulating control, for valve series: V5011, V5013, V5015, V5016, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Stem position at control signal loss: selectable: closed, half open, open
Position feedback: 2..10V=
End switches: optional
Supply voltage: 24 Vac
Stem force: 1800N
Control input signal: 0/2..10V=; 0/4..20mA
Manual operation: yes

38 mm; 1800 N
Stroke: 38mm
Runtime: 3.5min


ML7425A6008

Centraline Actuator 0/2..10V, 20 mm 600 N, ML7420/ML7425

Electrical actuator modulating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Stem position at control signal loss: adjustable
End switches: optional
The control action is reversable. For ML7425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Supply voltage: 24 Vac
Stem force: 600N
Stroke: 20mm

20 mm; 600 N, Spring return
Control input signal: 0/2..10V=
Power loss action: stem extends
Manual operation: no
Runtime: 1.8min
Spring return: yes
Position feedback: 2..10V=


ML7425B6007

Centraline Actuator 0/2..10V, 20 mm 600 N, ML7420/ML7425

Electrical actuator modulating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050, V5328, V5329.
Protection class: IP54
Position indication: scale plate
Stem position at control signal loss: adjustable
End switches: optional
The control action is reversable. For ML7425-models: approved according DIN EN 14597 (up to 130 oC) in combination with V5016A/V5025A/V5328A/V5049A.
Supply voltage: 24 Vac
Stem force: 600N
Stroke: 20mm

20 mm; 600 N, Spring return
Control input signal: 0/2..10V=
Power loss action: stem retracts
Manual operation: no
Runtime: 1.8min
Spring return: yes
Position feedback: 2..10V=


ML7430E1005

Centraline Actuator 0/2..10V for district heating, DHWS, 6,5 mm 400 N, ML7430/ML7435

Electrical actuator modulating control, for valve series: V5825B. Also suitable for V5832B/V5833A-series (DN25..40).
Protection class: IP54
For ML7435E1004: approved according DIN EN 14597 in combination with V5825B.
Supply voltage: 24 Vac
Stem force: 400N
Control input signal: 0/2..10V=
Stroke: 6.5mm

6,5 mm; 400 N
Power loss action: no
Manual operation: yes
Runtime: 15s
Spring return: no


ML7435E1004

Centraline Actuator 0/2..10V for district heating, DHWS, 6,5 mm 400 N, ML7430/ML7435

Electrical actuator modulating control, for valve series: V5825B. Also suitable for V5832B/V5833A-series (DN25..40).
Protection class: IP54
For ML7435E1004: approved according DIN EN 14597 in combination with V5825B.
Supply voltage: 24 Vac
Stem force: 400N
Control input signal: 0/2..10V=
Stroke: 6.5mm

6,5 mm; 400 N
Power loss action: stem retracts
Manual operation: no
Runtime: 60s
Spring return: yes


MP953A5005

Centraline Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

20 mm
Pressure range kPa: 34,5 or 69
Adjustable start point: 20.7...69kPa
Positioner: yes
Stroke: 20mm
Action actuator stem: extends
Max. ambient temperature: 70C
Diaphragm: 5in.


MP953A5039

Centraline Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

20 mm
Pressure range kPa: 34,5 or 69
Adjustable start point: 20.7...69kPa
Positioner: yes
Stroke: 20mm
Action actuator stem: extends
Max. ambient temperature: 70C
Diaphragm: 8in.


MP953A5054

Centraline Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

38 mm
Pressure range kPa: 34,5 or 69
Adjustable start point: 20.7...69kPa
Positioner: yes
Stroke: 38mm
Action actuator stem: extends
Max. ambient temperature: 70C
Diaphragm: 13in.


MP953B5003

Centraline Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

20 mm
Pressure range kPa: 34,5 or 69
Adjustable start point: 20.7...69kPa
Positioner: yes
Stroke: 20mm
Action actuator stem: retracts
Max. ambient temperature: 70C
Diaphragm: 7in.


MP953C5001

Centraline Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

20 mm
Pressure range kPa: 13,8...48,3
Adjustable start point: no
Positioner: no
Stroke: 20mm
Action actuator stem: extends
Max. ambient temperature: 120C
Diaphragm: 5in.


MP953C5019

Centraline Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

20 mm
Pressure range kPa: 55,2...82,8
Adjustable start point: no
Positioner: no
Stroke: 20mm
Action actuator stem: extends
Max. ambient temperature: 120C
Diaphragm: 5in.


MP953C5027

Centraline Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

20 mm
Pressure range kPa: 27,6...75,9
Adjustable start point: no
Positioner: no
Stroke: 20mm
Action actuator stem: extends
Max. ambient temperature: 120C
Diaphragm: 5in.


MP953C5068

Centraline Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

20 mm
Pressure range kPa: 13,8...48,3
Adjustable start point: no
Positioner: no
Stroke: 20mm
Action actuator stem: extends
Max. ambient temperature: 120C
Diaphragm: 8in.


MP953C5076

Centraline Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

20 mm
Pressure range kPa: 55,2...82,8
Adjustable start point: no
Positioner: no
Stroke: 20mm
Action actuator stem: extends
Max. ambient temperature: 120C
Diaphragm: 8in.


MP953C5084

Centraline Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

20 mm
Pressure range kPa: 27,6...75,9
Adjustable start point: no
Positioner: no
Stroke: 20mm
Action actuator stem: extends
Max. ambient temperature: 120C
Diaphragm: 8in.


MP953C5142

Centraline Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

38 mm
Pressure range kPa: 13,8...48,3
Adjustable start point: no
Positioner: no
Stroke: 38mm
Action actuator stem: extends
Max. ambient temperature: 120C
Diaphragm: 13in.


MP953C5159

Centraline Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

38 mm
Pressure range kPa: 27,6...75,9
Adjustable start point: no
Positioner: no
Stroke: 38mm
Action actuator stem: extends
Max. ambient temperature: 120C
Diaphragm: 13in.


MP953D5009

Centraline Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

20 mm
Pressure range kPa: 55,2...82,8
Adjustable start point: no
Positioner: no
Stroke: 20mm
Action actuator stem: retracts
Max. ambient temperature: 120C
Diaphragm: 7in.


MP953D5025

Centraline Pneumatic actuator, MP953

Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5016, V5025, V5328, V5329.
Protection class: IP54
Action: direct or reverse acting
Max. operating pressure: 140kPa
Rolling diaphragm
Max. safe air pressure: 172kPa

20 mm
Pressure range kPa: 27,6...75,9
Adjustable start point: no
Positioner: no
Stroke: 20mm
Action actuator stem: retracts
Max. ambient temperature: 120C
Diaphragm: 7in.


MT-ADAPT-HP

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T
Adapters

Mounting adapter for Herz/Polytherm valves; 10 units



MT-ADAPT-HW

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T
Adapters

Extra mounting adapters M30 x 1,5; 10 units



MT-CABLE-10M

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T
Plug-in cable (not for models with end switch)

Cable 10 meter; 10 units



MT-CABLE-2.5M

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T
Plug-in cable (not for models with end switch)

Cable 2,5 meter; 10 units



MT-CABLE-5M

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T
Plug-in cable (not for models with end switch)

Cable 5 meter; 10 units



MT-CLIP

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T
Accessories

Extra mounting clips; 10 units



MT4-024-NC

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem extends
Stroke: 2.5mm
End switches: no
Runtime: 4min
Initial current: 0.2A
Cable length: 1m


MT4-024-NC-2.5M

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem extends
Stroke: 2.5mm
End switches: no
Runtime: 4min
Initial current: 0.2A
Cable length: 2.5m


MT4-024-NO

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem retracts
Stroke: 2.5mm
End switches: no
Runtime: 4min
Initial current: 0.2A
Cable length: 1m


MT4-024-NO-2.5M

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem retracts
Stroke: 2.5mm
End switches: no
Runtime: 4min
Initial current: 0.2A
Cable length: 2.5m


MT4-024S-NC

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem extends
Stroke: 2.5mm
End switches: 1
Runtime: 4min
Initial current: 0.2A
Cable length: 1m


MT4-024S-NO

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem retracts
Stroke: 2.5mm
End switches: 1
Runtime: 4min
Initial current: 0.2A
Cable length: 1m


MT4-230-NC

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem extends
Stroke: 2.5mm
End switches: no
Runtime: 4min
Initial current: 0.4A
Cable length: 1m


MT4-230-NC-2.5M

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem extends
Stroke: 2.5mm
End switches: no
Runtime: 4min
Initial current: 0.4A
Cable length: 2.5m


MT4-230-NO

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem retracts
Stroke: 2.5mm
End switches: no
Runtime: 4min
Initial current: 0.4A
Cable length: 1m


MT4-230-NO-2.5M

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem retracts
Stroke: 2.5mm
End switches: no
Runtime: 4min
Initial current: 0.4A
Cable length: 2.5m


MT4-230S-NC

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem extends
Stroke: 2.5mm
End switches: 1
Runtime: 4min
Initial current: 0.4A
Cable length: 1m


MT4-230S-NO

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

2,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem retracts
Stroke: 2.5mm
End switches: 1
Runtime: 4min
Initial current: 0.4A
Cable length: 1m


MT8-024-NC

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem extends
Stroke: 6.5mm
End switches: no
Runtime: 6min
Initial current: 0.2A
Cable length: 1m


MT8-024-NC-2.5M

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem extends
Stroke: 6.5mm
End switches: no
Runtime: 6min
Initial current: 0.2A
Cable length: 2.5m


MT8-024-NO

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem retracts
Stroke: 6.5mm
End switches: no
Runtime: 6min
Initial current: 0.2A
Cable length: 1m


MT8-024-NO-2.5M

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem retracts
Stroke: 6.5mm
End switches: no
Runtime: 6min
Initial current: 0.2A
Cable length: 2.5m


MT8-024S-NC

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem extends
Stroke: 6.5mm
End switches: 1
Runtime: 6min
Initial current: 0.2A
Cable length: 1m


MT8-024S-NO

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 24 Vac/dc
Power loss action: stem retracts
Stroke: 6.5mm
End switches: 1
Runtime: 6min
Initial current: 0.2A
Cable length: 1m


MT8-230-NC

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem extends
Stroke: 6.5mm
End switches: no
Runtime: 6.5min
Initial current: 0.4A
Cable length: 1m


MT8-230-NC-2.5M

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem extends
Stroke: 6.5mm
End switches: no
Runtime: 6.5min
Initial current: 0.4A
Cable length: 2.5m


MT8-230-NO

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem retracts
Stroke: 6.5mm
End switches: no
Runtime: 6.5min
Initial current: 0.4A
Cable length: 1m


MT8-230-NO-2.5M

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem retracts
Stroke: 6.5mm
End switches: no
Runtime: 6.5min
Initial current: 0.4A
Cable length: 2.5m


MT8-230S-NC

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem extends
Stroke: 6.5mm
End switches: 1
Runtime: 6.5min
Initial current: 0.4A
Cable length: 1m


MT8-230S-NO

Centraline Actuator thermoelectric for zone control 2,5/6,5 mm 90 N, Smart-T

Electrical actuator on/off control, and PWM control.
Protection class: IP44
Position indication: with red indicator
End switch function/capacity: SPST, capacity 5(3) A; contact closes at power on
Stem force: 90N
Control input signal: 2-pt
Actuator supplied with mounting clip (MT-CLIP) and M30 x 1,5 adapter (MT-ADAPT-HW).
Other adapters on request.
Other cable length, or special connectors, on request.
Effective stroke for valves 2,5/6,5 mm; maximum stroke 4/8 mm.
Fits to closing dimension 11,5 +/- 0,3 mm

6,5 mm; 90 N
Supply voltage: 230 Vac
Power loss action: stem retracts
Stroke: 6.5mm
End switches: 1
Runtime: 6.5min
Initial current: 0.4A
Cable length: 1m


MVC-40-AC3

Centraline EAGLEHAWK Integrated Plant Control
Extra parts for EAGLEHAWK controller

Strain relief; package of 10



MVC-80-AC1

Centraline EAGLEHAWK Integrated Plant Control
Extra parts for EAGLEHAWK controller

Terminal cover (color: RAL9011); package of 10



MVC-80-AC2

Centraline EAGLEHAWK Integrated Plant Control
Extra parts for EAGLEHAWK controller

Front door mounting accessory (color: RAL9011); package of 10



MVN613A1500

Centraline Rotary Actuator, MVN

Electrical actuator for VBG control ball valves, DN15-DN32.
Actuator can easily be clicked on valve - no tool required.
Protection class: IP40
Position indication: scale plate
Torque: 3Nm
Angle of rotation: 90o
Manual operation: yes
Cable length: 1.5m

Floating control
Supply voltage: 24 Vac
Control input signal: 2/3-pt
Runtime: 108s


MVN663A1500

Centraline Rotary Actuator, MVN

Electrical actuator for VBG control ball valves, DN15-DN32.
Actuator can easily be clicked on valve - no tool required.
Protection class: IP40
Position indication: scale plate
Torque: 3Nm
Angle of rotation: 90o
Manual operation: yes
Cable length: 1.5m

Floating control
Supply voltage: 230 Vac
Control input signal: 2/3-pt
Runtime: 108s


MVN713A1500

Centraline Rotary Actuator, MVN

Electrical actuator for VBG control ball valves, DN15-DN32.
Actuator can easily be clicked on valve - no tool required.
Protection class: IP40
Position indication: scale plate
Torque: 3Nm
Angle of rotation: 90o
Manual operation: yes
Cable length: 1.5m

Modulating control. Control action reversable.
Supply voltage: 24 Vac/dc
Control input signal: 0/2..10V=
Runtime: 90s


MVNAAA/U

Centraline Two way characterized control ball valves, PN25, DN15-50, VBG2
Accessories for DN15..32 valves

Replacement valve adaptor standard profile, for VBG valves, DN15..DN32



MVNAT3/B

Centraline Rotary Actuator, MVN
Accessories

Replacement screw terminal block, pluggable



N05010

Centraline Damper actuator 5/10 Nm, SmartAct

Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
End switch function/capacity: SPDT switch 230 V, 5(3) A for models with end switch
Shaft mounting: for round shafts 8..16 mm; square shafts 6..13 mm
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Rotation direction selectable by switch.
Adjustable mechanical end limits included.
Built in rotation limiter: yes
Manual operation: yes

For damper area of 1 square meter
Supply voltage: 24 Vac/dc
Control input signal: 0/2..10V=;2/3-pt
End switches: no
Runtime: 90/110s
Torque: 5Nm
Damper area: 1m2


N05010-SW2

Centraline Damper actuator 5/10 Nm, SmartAct

Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
End switch function/capacity: SPDT switch 230 V, 5(3) A for models with end switch
Shaft mounting: for round shafts 8..16 mm; square shafts 6..13 mm
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Rotation direction selectable by switch.
Adjustable mechanical end limits included.
Built in rotation limiter: yes
Manual operation: yes

For damper area of 1 square meter
Supply voltage: 24 Vac/dc
Control input signal: 0/2..10V=;2/3-pt
End switches: 2
Runtime: 90/110s
Torque: 5Nm
Damper area: 1m2


N05230-2POS

Centraline Damper actuator 5/10 Nm, SmartAct

Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
End switch function/capacity: SPDT switch 230 V, 5(3) A for models with end switch
Shaft mounting: for round shafts 8..16 mm; square shafts 6..13 mm
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Rotation direction selectable by switch.
Adjustable mechanical end limits included.
Built in rotation limiter: yes
Manual operation: yes

For damper area of 1 square meter
Supply voltage: 230 Vac
Control input signal: 2-pt
End switches: no
Runtime: max. 110s
Torque: 5Nm
Damper area: 1m2


N0524

Centraline Damper actuator 5/10 Nm, SmartAct

Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
End switch function/capacity: SPDT switch 230 V, 5(3) A for models with end switch
Shaft mounting: for round shafts 8..16 mm; square shafts 6..13 mm
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Rotation direction selectable by switch.
Adjustable mechanical end limits included.
Built in rotation limiter: yes
Manual operation: yes

For damper area of 1 square meter
Supply voltage: 24 Vac/dc
Control input signal: 2/3-pt
End switches: no
Runtime: 110s
Torque: 5Nm
Damper area: 1m2


N0524-SW2

Centraline Damper actuator 5/10 Nm, SmartAct

Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
End switch function/capacity: SPDT switch 230 V, 5(3) A for models with end switch
Shaft mounting: for round shafts 8..16 mm; square shafts 6..13 mm
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Rotation direction selectable by switch.
Adjustable mechanical end limits included.
Built in rotation limiter: yes
Manual operation: yes

For damper area of 1 square meter
Supply voltage: 24 Vac/dc
Control input signal: 2/3-pt
End switches: 2
Runtime: 110s
Torque: 5Nm
Damper area: 1m2


N10010

Centraline Damper actuator 5/10 Nm, SmartAct

Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
End switch function/capacity: SPDT switch 230 V, 5(3) A for models with end switch
Shaft mounting: for round shafts 8..16 mm; square shafts 6..13 mm
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Rotation direction selectable by switch.
Adjustable mechanical end limits included.
Built in rotation limiter: yes
Manual operation: yes

For damper area of 2 square meters
Supply voltage: 24 Vac/dc
Control input signal: 0/2..10V=;2/3-pt
End switches: no
Runtime: 90/110s
Torque: 10Nm
Damper area: 2m2


N10010-SW2

Centraline Damper actuator 5/10 Nm, SmartAct

Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
End switch function/capacity: SPDT switch 230 V, 5(3) A for models with end switch
Shaft mounting: for round shafts 8..16 mm; square shafts 6..13 mm
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Rotation direction selectable by switch.
Adjustable mechanical end limits included.
Built in rotation limiter: yes
Manual operation: yes

For damper area of 2 square meters
Supply voltage: 24 Vac/dc
Control input signal: 0/2..10V=;2/3-pt
End switches: 2
Runtime: 90/110s
Torque: 10Nm
Damper area: 2m2


N10230-2POS

Centraline Damper actuator 5/10 Nm, SmartAct

Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
End switch function/capacity: SPDT switch 230 V, 5(3) A for models with end switch
Shaft mounting: for round shafts 8..16 mm; square shafts 6..13 mm
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Rotation direction selectable by switch.
Adjustable mechanical end limits included.
Built in rotation limiter: yes
Manual operation: yes

For damper area of 2 square meters
Supply voltage: 230 Vac
Control input signal: 2-pt
End switches: no
Runtime: max. 140s
Torque: 10Nm
Damper area: 2m2


N1024

Centraline Damper actuator 5/10 Nm, SmartAct

Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
End switch function/capacity: SPDT switch 230 V, 5(3) A for models with end switch
Shaft mounting: for round shafts 8..16 mm; square shafts 6..13 mm
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Rotation direction selectable by switch.
Adjustable mechanical end limits included.
Built in rotation limiter: yes
Manual operation: yes

For damper area of 2 square meters
Supply voltage: 24 Vac/dc
Control input signal: 2/3-pt
End switches: no
Runtime: 110s
Torque: 10Nm
Damper area: 2m2


N1024-SW2

Centraline Damper actuator 5/10 Nm, SmartAct

Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
End switch function/capacity: SPDT switch 230 V, 5(3) A for models with end switch
Shaft mounting: for round shafts 8..16 mm; square shafts 6..13 mm
Removable wiring box, with cable gland M20x1,5 1/2" NPT.
Rotation direction selectable by switch.
Adjustable mechanical end limits included.
Built in rotation limiter: yes
Manual operation: yes

For damper area of 2 square meters
Supply voltage: 24 Vac/dc
Control input signal: 2/3-pt
End switches: 2
Runtime: 110s
Torque: 10Nm
Damper area: 2m2


N20010

Centraline Damper actuator 20/34 Nm, SmartAct

Direct-coupled actuator with self-centering shaft adapter.
For air dampers, air handlers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
Position indication: rotational angle scales 0..90o, 90..0o
End switch function/capacity: SPDT switch 230V, 5 (3) A for models with end switch
Shaft mounting: for round shafts 10..27 mm; square shafts 10..18 mm
Rotation direction selectable by switch
When power is removed, the actuator remains in position
Removable wiring box, with cable gland M20x1,5 1/2" NPT
Actuator supplied with complete package mounting parts
For modulating control models: Control input signal can be voltage or current
For modulating control models: Autoadapt dipswitch. With this function the full span of the control input signal will be used for the applicable angle or rotation
Manual operation: yes

For damper area of 4 square meters
Supply voltage: 24 Vac/dc
Control input signal: 0/2..10V=
Built in rotation limiter: yes
End switches: optional
Position feedback: 0/2..10V=
Runtime: 95s
Torque: 20Nm
Damper area: 4m2


N20010-SW2

Centraline Damper actuator 20/34 Nm, SmartAct

Direct-coupled actuator with self-centering shaft adapter.
For air dampers, air handlers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
Position indication: rotational angle scales 0..90o, 90..0o
End switch function/capacity: SPDT switch 230V, 5 (3) A for models with end switch
Shaft mounting: for round shafts 10..27 mm; square shafts 10..18 mm
Rotation direction selectable by switch
When power is removed, the actuator remains in position
Removable wiring box, with cable gland M20x1,5 1/2" NPT
Actuator supplied with complete package mounting parts
For modulating control models: Control input signal can be voltage or current
For modulating control models: Autoadapt dipswitch. With this function the full span of the control input signal will be used for the applicable angle or rotation
Manual operation: yes

For damper area of 4 square meters
Supply voltage: 24 Vac/dc
Control input signal: 0/2..10V=
Built in rotation limiter: yes
End switches: 2
Position feedback: 0/2..10V=
Runtime: 95s
Torque: 20Nm
Damper area: 4m2


N20230

Centraline Damper actuator 20/34 Nm, SmartAct

Direct-coupled actuator with self-centering shaft adapter.
For air dampers, air handlers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
Position indication: rotational angle scales 0..90o, 90..0o
End switch function/capacity: SPDT switch 230V, 5 (3) A for models with end switch
Shaft mounting: for round shafts 10..27 mm; square shafts 10..18 mm
Rotation direction selectable by switch
When power is removed, the actuator remains in position
Removable wiring box, with cable gland M20x1,5 1/2" NPT
Actuator supplied with complete package mounting parts
For modulating control models: Control input signal can be voltage or current
For modulating control models: Autoadapt dipswitch. With this function the full span of the control input signal will be used for the applicable angle or rotation
Manual operation: yes

For damper area of 4 square meters
Supply voltage: 230 Vac
Control input signal: 2/3-pt
Built in rotation limiter: yes
End switches: optional
Position feedback: no
Runtime: 110s
Torque: 20Nm
Damper area: 4m2


N20230-SW2

Centraline Damper actuator 20/34 Nm, SmartAct

Direct-coupled actuator with self-centering shaft adapter.
For air dampers, air handlers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
Position indication: rotational angle scales 0..90o, 90..0o
End switch function/capacity: SPDT switch 230V, 5 (3) A for models with end switch
Shaft mounting: for round shafts 10..27 mm; square shafts 10..18 mm
Rotation direction selectable by switch
When power is removed, the actuator remains in position
Removable wiring box, with cable gland M20x1,5 1/2" NPT
Actuator supplied with complete package mounting parts
For modulating control models: Control input signal can be voltage or current
For modulating control models: Autoadapt dipswitch. With this function the full span of the control input signal will be used for the applicable angle or rotation
Manual operation: yes

For damper area of 4 square meters
Supply voltage: 230 Vac
Control input signal: 2/3-pt
Built in rotation limiter: yes
End switches: 2
Position feedback: no
Runtime: 110s
Torque: 20Nm
Damper area: 4m2


N2024

Centraline Damper actuator 20/34 Nm, SmartAct

Direct-coupled actuator with self-centering shaft adapter.
For air dampers, air handlers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
Position indication: rotational angle scales 0..90o, 90..0o
End switch function/capacity: SPDT switch 230V, 5 (3) A for models with end switch
Shaft mounting: for round shafts 10..27 mm; square shafts 10..18 mm
Rotation direction selectable by switch
When power is removed, the actuator remains in position
Removable wiring box, with cable gland M20x1,5 1/2" NPT
Actuator supplied with complete package mounting parts
For modulating control models: Control input signal can be voltage or current
For modulating control models: Autoadapt dipswitch. With this function the full span of the control input signal will be used for the applicable angle or rotation
Manual operation: yes

For damper area of 4 square meters
Supply voltage: 24 Vac
Control input signal: 2/3-pt
Built in rotation limiter: yes
End switches: optional
Position feedback: no
Runtime: 110s
Torque: 20Nm
Damper area: 4m2


N2024-SW2

Centraline Damper actuator 20/34 Nm, SmartAct

Direct-coupled actuator with self-centering shaft adapter.
For air dampers, air handlers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
Position indication: rotational angle scales 0..90o, 90..0o
End switch function/capacity: SPDT switch 230V, 5 (3) A for models with end switch
Shaft mounting: for round shafts 10..27 mm; square shafts 10..18 mm
Rotation direction selectable by switch
When power is removed, the actuator remains in position
Removable wiring box, with cable gland M20x1,5 1/2" NPT
Actuator supplied with complete package mounting parts
For modulating control models: Control input signal can be voltage or current
For modulating control models: Autoadapt dipswitch. With this function the full span of the control input signal will be used for the applicable angle or rotation
Manual operation: yes

For damper area of 4 square meters
Supply voltage: 24 Vac
Control input signal: 2/3-pt
Built in rotation limiter: yes
End switches: 2
Position feedback: no
Runtime: 110s
Torque: 20Nm
Damper area: 4m2


N34010

Centraline Damper actuator 20/34 Nm, SmartAct

Direct-coupled actuator with self-centering shaft adapter.
For air dampers, air handlers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
Position indication: rotational angle scales 0..90o, 90..0o
End switch function/capacity: SPDT switch 230V, 5 (3) A for models with end switch
Shaft mounting: for round shafts 10..27 mm; square shafts 10..18 mm
Rotation direction selectable by switch
When power is removed, the actuator remains in position
Removable wiring box, with cable gland M20x1,5 1/2" NPT
Actuator supplied with complete package mounting parts
For modulating control models: Control input signal can be voltage or current
For modulating control models: Autoadapt dipswitch. With this function the full span of the control input signal will be used for the applicable angle or rotation
Manual operation: yes

For damper area of 6 square meters
Supply voltage: 24 Vac/dc
Control input signal: 0/2..10V=
Built in rotation limiter: no
End switches: optional
Position feedback: 0/2..10V=
Runtime: 95s
Torque: 34Nm
Damper area: 6m2


N34230

Centraline Damper actuator 20/34 Nm, SmartAct

Direct-coupled actuator with self-centering shaft adapter.
For air dampers, air handlers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
Position indication: rotational angle scales 0..90o, 90..0o
End switch function/capacity: SPDT switch 230V, 5 (3) A for models with end switch
Shaft mounting: for round shafts 10..27 mm; square shafts 10..18 mm
Rotation direction selectable by switch
When power is removed, the actuator remains in position
Removable wiring box, with cable gland M20x1,5 1/2" NPT
Actuator supplied with complete package mounting parts
For modulating control models: Control input signal can be voltage or current
For modulating control models: Autoadapt dipswitch. With this function the full span of the control input signal will be used for the applicable angle or rotation
Manual operation: yes

For damper area of 6 square meters
Supply voltage: 230 Vac
Control input signal: 2/3-pt
Built in rotation limiter: no
End switches: optional
Position feedback: no
Runtime: 110s
Torque: 34Nm
Damper area: 6m2


N3424

Centraline Damper actuator 20/34 Nm, SmartAct

Direct-coupled actuator with self-centering shaft adapter.
For air dampers, air handlers, ventilation flaps, louvers and VAV-units.
Protection class: IP54
Position indication: rotational angle scales 0..90o, 90..0o
End switch function/capacity: SPDT switch 230V, 5 (3) A for models with end switch
Shaft mounting: for round shafts 10..27 mm; square shafts 10..18 mm
Rotation direction selectable by switch
When power is removed, the actuator remains in position
Removable wiring box, with cable gland M20x1,5 1/2" NPT
Actuator supplied with complete package mounting parts
For modulating control models: Control input signal can be voltage or current
For modulating control models: Autoadapt dipswitch. With this function the full span of the control input signal will be used for the applicable angle or rotation
Manual operation: yes

For damper area of 6 square meters
Supply voltage: 24 Vac
Control input signal: 2/3-pt
Built in rotation limiter: no
End switches: optional
Position feedback: no
Runtime: 110s
Torque: 34Nm
Damper area: 6m2


NX-FAN-4

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Main cooling fan spare parts for inverters
Product description: NXL HVAC / NXS spare part fan size 4 (HVAC03-HVAC12, NXS0003-NXS0012)
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NX-FAN-5

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Main cooling fan spare parts for inverters
Product description: NXL HVAC / NXS spare part fan size 5 (HVAC16-HVAC31, NXS0016-NXS0031)
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NX-FAN-6

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Main cooling fan spare parts for inverters
Product description: NXL HVAC / NXS spare part fan size 6 (HVAC38-HVAC61, NXS0038-NXS0061)
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NX-FAN-7

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Main cooling fan spare parts for inverters
Product description: NXS spare part fan size 7 (NXS0072-NXS0105)
HVAC400: no
NXL HVAC: no
NXS: yes
HVAC232/402: no


NXIP54FR4

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NXL HVAC/NXS IP21 to IP54 upgrade kits
Product description: IP54 enclosure upgrade kit for NXL HVAC/NXS size 4 (HVAC03-HVAC12, NXS0003-NXS0012)
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NXIP54FR5

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NXL HVAC/NXS IP21 to IP54 upgrade kits
Product description: IP54 enclosure upgrade kit for NXL HVAC/NXS size 5 (HVAC16-HVAC31, NXS0016-NXS0031)
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NXIP54FR6

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NXL HVAC/NXS IP21 to IP54 upgrade kits
Product description: IP54 enclosure upgrade kit for NXL HVAC/NXS size 6 (HVAC38-HVAC61, NXS0038-NXS0061)
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NXLOPTAA

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Input/output expander cards
Product description: 3 digital inputs, 1 relay (NO/NC), 1 digital output
HVAC400: no
NXL HVAC: yes
NXS: no
HVAC232/402: no


NXLPANC

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NXL Display panels
Product description: NXL standard 7-segment display
HVAC400: no
NXL HVAC: yes
NXS: no
HVAC232/402: no


NXLPANRS

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NXL/NXS PC connection tools and cables
Product description: NXL RS232 adapter (for PC connection)
HVAC400: no
NXL HVAC: yes
NXS: no
HVAC232/402: no


NXOPTA1

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Input/output expander cards
Product description: standard NXS slot A board: 6 DI, 1 DO (open collector), 2 AI, 1 AO
HVAC400: no
NXL HVAC: no
NXS: yes
HVAC232/402: no


NXOPTB2

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Input/output expander cards
Product description: 2 relays (1 NO, 1 NO/NC), 1 thermistor
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NXOPTB8

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Input/output expander cards
Product description: 3 Pt100 input
HVAC400: no
NXL HVAC: no
NXS: yes
HVAC232/402: no


NXOPTC2

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Fieldbus cards
Product description: Modbus/N2 (RS485)
HVAC400: no
NXL HVAC: no
NXS: yes
HVAC232/402: no


NXOPTC3

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Fieldbus cards
Product description: Profibus DP
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NXOPTC6

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Fieldbus cards
Product description: CANopen (slave)
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NXOPTC7

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Fieldbus cards
Product description: DeviceNet
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NXOPTCJ

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

Fieldbus cards
Product description: BACnet MS/TP (RS485)
HVAC400: no
NXL HVAC: yes
NXS: yes
HVAC232/402: no


NXPANA

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NXS Display panels
Product description: NXS standard alpha-numeric display
HVAC400: no
NXL HVAC: no
NXS: yes
HVAC232/402: no


NXPANG

Centraline Parts and accessories for inverters

Honeywell inverter inputs/outputs can be easily configured by adding or changing option cards. These option boards are designed to easy installation even on the site and are automatically identified by the inverter software.

NXS Display panels
Product description: NXS special display for Cyrillic or Chinese letters
HVAC400: no
NXL HVAC: no
NXS: yes
HVAC232/402: no


NXS0003V35A2H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Low overload (for Fan/Pump): 1.1kW
Low overload Icont: 3.1A
High overload (for Machines): 0.75kW
High overload Icont: 2.2A
Brake chopper: integrated


NXS0003V35A5H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Low overload (for Fan/Pump): 1.1kW
Low overload Icont: 3.1A
High overload (for Machines): 0.75kW
High overload Icont: 2.2A
Brake chopper: integrated


NXS0004V35A2H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Low overload (for Fan/Pump): 1.5kW
Low overload Icont: 4A
High overload (for Machines): 1.1kW
High overload Icont: 3.1A
Brake chopper: integrated


NXS0004V35A5H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Low overload (for Fan/Pump): 1.5kW
Low overload Icont: 4A
High overload (for Machines): 1.1kW
High overload Icont: 3.1A
Brake chopper: integrated


NXS0005V35A2H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Low overload (for Fan/Pump): 2.2kW
Low overload Icont: 5.4A
High overload (for Machines): 1.5kW
High overload Icont: 4A
Brake chopper: integrated


NXS0005V35A5H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Low overload (for Fan/Pump): 2.2kW
Low overload Icont: 5.4A
High overload (for Machines): 1.5kW
High overload Icont: 4A
Brake chopper: integrated


NXS0007V35A2H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Low overload (for Fan/Pump): 3kW
Low overload Icont: 7A
High overload (for Machines): 2.2kW
High overload Icont: 5.4A
Brake chopper: integrated


NXS0007V35A5H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Low overload (for Fan/Pump): 3kW
Low overload Icont: 7A
High overload (for Machines): 2.2kW
High overload Icont: 5.4A
Brake chopper: integrated


NXS0009V35A2H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Low overload (for Fan/Pump): 4kW
Low overload Icont: 9A
High overload (for Machines): 3kW
High overload Icont: 7A
Brake chopper: integrated


NXS0009V35A5H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Low overload (for Fan/Pump): 4kW
Low overload Icont: 9A
High overload (for Machines): 3kW
High overload Icont: 7A
Brake chopper: integrated


NXS0012V35A2H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Low overload (for Fan/Pump): 5.5kW
Low overload Icont: 12A
High overload (for Machines): 4kW
High overload Icont: 9A
Brake chopper: integrated


NXS0012V35A5H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Low overload (for Fan/Pump): 5.5kW
Low overload Icont: 12A
High overload (for Machines): 4kW
High overload Icont: 9A
Brake chopper: integrated


NXS0016V35A2H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Low overload (for Fan/Pump): 7.5kW
Low overload Icont: 16A
High overload (for Machines): 5.5kW
High overload Icont: 12A
Brake chopper: integrated


NXS0016V35A5H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Low overload (for Fan/Pump): 7.5kW
Low overload Icont: 16A
High overload (for Machines): 5.5kW
High overload Icont: 12A
Brake chopper: integrated


NXS0022V35A2H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Low overload (for Fan/Pump): 11kW
Low overload Icont: 22A
High overload (for Machines): 7.5kW
High overload Icont: 16A
Brake chopper: integrated


NXS0022V35A5H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Low overload (for Fan/Pump): 11kW
Low overload Icont: 22A
High overload (for Machines): 7.5kW
High overload Icont: 16A
Brake chopper: integrated


NXS0031V35A2H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Low overload (for Fan/Pump): 15kW
Low overload Icont: 31A
High overload (for Machines): 11kW
High overload Icont: 22A
Brake chopper: integrated


NXS0031V35A5H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Low overload (for Fan/Pump): 15kW
Low overload Icont: 31A
High overload (for Machines): 11kW
High overload Icont: 22A
Brake chopper: integrated


NXS0038V35A2H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Low overload (for Fan/Pump): 18.5kW
Low overload Icont: 38A
High overload (for Machines): 15kW
High overload Icont: 31A
Brake chopper: integrated


NXS0038V35A5H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Low overload (for Fan/Pump): 18.5kW
Low overload Icont: 38A
High overload (for Machines): 15kW
High overload Icont: 31A
Brake chopper: integrated


NXS0045V35A2H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Low overload (for Fan/Pump): 22kW
Low overload Icont: 45A
High overload (for Machines): 18.5kW
High overload Icont: 38A
Brake chopper: integrated


NXS0045V35A5H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP54, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP54
Low overload (for Fan/Pump): 22kW
Low overload Icont: 45A
High overload (for Machines): 18.5kW
High overload Icont: 38A
Brake chopper: integrated


NXS0061V35A2H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured software package with predefined applications
start-up wizard
detachable multilingual HMI-panel with memory and backup functions
flexible I/O configuration; 5 slots
inputs/outputs: 2 analog inputs, 6 digital inputs, 2 relays, 1 digital output, 1 thermistor input, 1 analog output
Series: NXS
Voltage: 400V
Output frequency: 0...320Hz
Frequency resolution: 0.01Hz
Serial communication: optional: LonWorks, Modbus RTU, Profibus DP, BACnet, Ethernet (Mobus/TCP), N2, DeviceNet, CANopen
Immunity: fulfills all EMC immunity requirements
Safety: EN61800-5, CE, UL, cUL
RFI-filter: integrated
http://inverter.ecc.emea.honeywell.com
1 phase input: no
3 phases input: yes

IP21, wall mounted; Emissions EN61800-3 (category C2), C-Tick
Protection class: IP21
Low overload (for Fan/Pump): 30kW
Low overload Icont: 61A
High overload (for Machines): 22kW
High overload Icont: 45A
Brake chopper: integrated


NXS0061V35A5H1

Centraline Inverters 1,1..400kW, IP21/IP54, NXS

Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally Low Overload inverters are used. Industrial or process installations normally require High Overload inverters.
Features: high featured s